Home
last modified time | relevance | path

Searched refs:PERF_SAMPLE_PHYS_ADDR (Results 1 – 18 of 18) sorted by relevance

/openbmc/linux/tools/perf/ui/browsers/
H A Dscripts.c45 if (attr->sample_type & PERF_SAMPLE_PHYS_ADDR) in attr_to_script()
/openbmc/linux/tools/perf/util/
H A Dbpf-filter.l86 phys_addr { return sample(PERF_SAMPLE_PHYS_ADDR); }
H A Dsynthetic-events.c1532 if (type & PERF_SAMPLE_PHYS_ADDR) in perf_event__sample_event_size()
1736 if (type & PERF_SAMPLE_PHYS_ADDR) { in perf_event__synthesize_sample()
H A Darm-spe.c1146 (PERF_SAMPLE_MASK | PERF_SAMPLE_PHYS_ADDR); in arm_spe_synth_events()
H A Devsel.c2654 if (type & PERF_SAMPLE_PHYS_ADDR) { in evsel__parse_sample()
H A Dsession.c1386 if (sample_type & PERF_SAMPLE_PHYS_ADDR) in dump_sample()
/openbmc/linux/tools/perf/util/bpf_skel/
H A Dsample_filter.bpf.c85 case PERF_SAMPLE_PHYS_ADDR: in perf_get_sample()
/openbmc/linux/arch/x86/events/amd/
H A Dibs.c998 if (sample_type & PERF_SAMPLE_PHYS_ADDR && op_data3.dc_phy_addr_valid) { in perf_ibs_parse_ld_st_data()
1000 data->sample_flags |= PERF_SAMPLE_PHYS_ADDR; in perf_ibs_parse_ld_st_data()
1012 sample_type & PERF_SAMPLE_PHYS_ADDR))) in perf_ibs_get_offset_max()
/openbmc/linux/tools/perf/tests/
H A Dsample-parsing.c172 if (type & PERF_SAMPLE_PHYS_ADDR) in samples_same()
/openbmc/linux/tools/include/uapi/linux/
H A Dperf_event.h159 PERF_SAMPLE_PHYS_ADDR = 1U << 19, enumerator
/openbmc/linux/include/uapi/linux/
H A Dperf_event.h159 PERF_SAMPLE_PHYS_ADDR = 1U << 19, enumerator
/openbmc/linux/tools/perf/Documentation/
H A Dperf-dlfilter.txt102 __u64 phys_addr; /* Refer PERF_SAMPLE_PHYS_ADDR in <linux/perf_event.h> */
H A Dperf-intel-pt.txt1082 PERF_SAMPLE_TRANSACTION | PERF_SAMPLE_PHYS_ADDR |
/openbmc/linux/arch/x86/events/intel/
H A Dds.c1181 PERF_SAMPLE_PHYS_ADDR | \
1608 PERF_SAMPLE_PHYS_ADDR | \
/openbmc/linux/arch/x86/events/
H A Dperf_event.h138 PERF_SAMPLE_TRANSACTION | PERF_SAMPLE_PHYS_ADDR | \
/openbmc/linux/kernel/events/
H A Dcore.c1874 if (sample_type & PERF_SAMPLE_PHYS_ADDR) in __perf_event_header_size()
7493 if (sample_type & PERF_SAMPLE_PHYS_ADDR) in perf_output_sample()
7693 PERF_SAMPLE_PHYS_ADDR, PERF_SAMPLE_ADDR); in perf_prepare_sample()
7810 if (filtered_sample_type & PERF_SAMPLE_PHYS_ADDR) { in perf_prepare_sample()
7812 data->sample_flags |= PERF_SAMPLE_PHYS_ADDR; in perf_prepare_sample()
12498 if ((attr.sample_type & PERF_SAMPLE_PHYS_ADDR)) { in SYSCALL_DEFINE5()
/openbmc/linux/arch/powerpc/perf/
H A Dcore-book3s.c2230 PERF_SAMPLE_PHYS_ADDR | \
/openbmc/linux/tools/perf/
H A Dbuiltin-script.c537 …evsel__do_check_stype(evsel, PERF_SAMPLE_PHYS_ADDR, "PHYS_ADDR", PERF_OUTPUT_PHYS_ADDR, allow_user… in evsel__check_attr()