H A Dopenbmc_message_registry.hppcecb4cb6 Mon Sep 23 11:09:59 CDT 2019 Cheng C Yang <cheng.c.yang@linux.intel.com> Add Power Unit Redundancy Log

Add Power Unit Redundancy Redfish Log.

Tested:
Tested:
When there are two PSU on the sytem, remove one AC cable on PSU. Then bellow
Redfish log will be created.
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/system/LogServices/EventLog/Entries/
1568504619_1",
"@odata.type": "#LogEntry.v1_4_0.LogEntry",
"Created": "2019-09-14T23:43:39+00:00",
"EntryType": "Event",
"Id": "1568504619_1",
"Message": "Power Unit Nonredundant but has sufficient resource.",
"MessageArgs": [],
"MessageId": "OpenBMC.0.1.PowerUnitNonRedundantSufficient",
"Name": "System Event Log Entry",
"Severity": "Warning"
},
Plug in the AC cable again, the Redfish log will show
{
"@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry",
"@odata.id": "/redfish/v1/Systems/system/LogServices/EventLog/Entries/
1568504628",
"@odata.type": "#LogEntry.v1_4_0.LogEntry",
"Created": "2019-09-14T23:43:48+00:00",
"EntryType": "Event",
"Id": "1568504628",
"Message": "Power Unit Redundancy regained.",
"MessageArgs": [],
"MessageId": "OpenBMC.0.1.PowerUnitRedundancyRegained",
"Name": "System Event Log Entry",
"Severity": "OK"
}

Signed-off-by: Cheng C Yang <cheng.c.yang@linux.intel.com>
Change-Id: I4f2d12e0dbc02f13062ea8e524b37248acf9c662