Home
last modified time | relevance | path

Searched hist:"8 b8abeed" (Results 1 – 1 of 1) sorted by relevance

/openbmc/openpower-occ-control/
H A Docc_manager.cpp8b8abeed Wed Aug 25 15:18:21 CDT 2021 Matt Spinler <spinler@us.ibm.com> Support 0xFF fru_type values

The OCC may put a value of 0xFF as the FRU type for some temperature
sensors to indicate they aren't available on the platform. In this
case, the OCC device driver won't even make a tempX_input file for them.

Check for this case and just continue on.

Signed-off-by: Matt Spinler <spinler@us.ibm.com>
Change-Id: I27dbc63270bfc60eed9d93eeb844625572839e38