Searched hist:"7 ee4d7e4" (Results 1 – 4 of 4) sorted by relevance
/openbmc/phosphor-power/phosphor-power-supply/test/ |
H A D | power_supply_tests.cpp | 7ee4d7e4 Fri Nov 19 14:48:23 CST 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add in detection of fan faults If the FANS bit in the STATUS_WORD turns on (A fan or airflow fault or warning has occurred), set a fan fault indicator in the power supply object. During analysis of the power supplies, if a fan fault has occurred, prioritize that over a temperature fault, include the STATUS_TEMPERATURE and STATUS_FANS_1_2 command responses in the error created. Call out the power supply with the fault. Tested: Verify no faults detected or logged on real hardware (Rainier 2S4U). Simulate fan 1 fault on Rainier 2S2U, 110015FF PEL created. Change-Id: Ifff5b4d96efe44b081a33caa01d70fdb578e57e3 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|
/openbmc/phosphor-power/phosphor-power-supply/ |
H A D | power_supply.hpp | 7ee4d7e4 Fri Nov 19 14:48:23 CST 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add in detection of fan faults If the FANS bit in the STATUS_WORD turns on (A fan or airflow fault or warning has occurred), set a fan fault indicator in the power supply object. During analysis of the power supplies, if a fan fault has occurred, prioritize that over a temperature fault, include the STATUS_TEMPERATURE and STATUS_FANS_1_2 command responses in the error created. Call out the power supply with the fault. Tested: Verify no faults detected or logged on real hardware (Rainier 2S4U). Simulate fan 1 fault on Rainier 2S2U, 110015FF PEL created. Change-Id: Ifff5b4d96efe44b081a33caa01d70fdb578e57e3 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|
H A D | power_supply.cpp | 7ee4d7e4 Fri Nov 19 14:48:23 CST 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add in detection of fan faults If the FANS bit in the STATUS_WORD turns on (A fan or airflow fault or warning has occurred), set a fan fault indicator in the power supply object. During analysis of the power supplies, if a fan fault has occurred, prioritize that over a temperature fault, include the STATUS_TEMPERATURE and STATUS_FANS_1_2 command responses in the error created. Call out the power supply with the fault. Tested: Verify no faults detected or logged on real hardware (Rainier 2S4U). Simulate fan 1 fault on Rainier 2S2U, 110015FF PEL created. Change-Id: Ifff5b4d96efe44b081a33caa01d70fdb578e57e3 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|
H A D | psu_manager.cpp | 7ee4d7e4 Fri Nov 19 14:48:23 CST 2021 Brandon Wyman <bjwyman@gmail.com> psu-ng: Add in detection of fan faults If the FANS bit in the STATUS_WORD turns on (A fan or airflow fault or warning has occurred), set a fan fault indicator in the power supply object. During analysis of the power supplies, if a fan fault has occurred, prioritize that over a temperature fault, include the STATUS_TEMPERATURE and STATUS_FANS_1_2 command responses in the error created. Call out the power supply with the fault. Tested: Verify no faults detected or logged on real hardware (Rainier 2S4U). Simulate fan 1 fault on Rainier 2S2U, 110015FF PEL created. Change-Id: Ifff5b4d96efe44b081a33caa01d70fdb578e57e3 Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
|