Searched hist:"3 c543605" (Results 1 – 1 of 1) sorted by relevance
/openbmc/entity-manager/schemas/ |
H A D | legacy.json | 3c543605 Thu Jul 29 00:14:36 CDT 2021 Rashmica Gupta <rashmica.g@gmail.com> Add optional hysteresis field to Thresholds This allows applications to use a hysteresis when clearing threshold alerts. For example, if a critical high temperature sensor threshold value is set to 50 with a hysteresis of 5, then the alarm property in the threshold interface is set when the temperature crosses 50 when increasing, and when the temperature decreases it isn't cleared until it gets to 45. At this point, this is only needed by the phosphor-virtual-sensor code which is going to get its sensor config from entity manager Signed-off-by: Matt Spinler <spinler@us.ibm.com> Signed-off-by: Rashmica Gupta <rashmica.g@gmail.com> Change-Id: I3d00746343c8a8c672aa77a702bcf65705d20b4c
|