Home
last modified time | relevance | path

Searched hist:"2474 adfa" (Results 1 – 5 of 5) sorted by relevance

/openbmc/bmcweb/redfish-core/lib/
H A Dthermal.hpp2474adfa Wed Sep 05 18:31:16 CDT 2018 Ed Tanous <ed.tanous@intel.com> Chassis: Power: Support get PowerSupply and Voltages
sensors information.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/a20f8b17c1efb92b9a8e95e8867d945bc6177804

Sensor module adds sensorType:"power" to retrieve power supply sensor
information.
This applicable to Power schema version 1.2.1

Limit:
- Not retrieve PowerControl information yet.
- Need to get UpperThresholdFatal and LowerThresholdFatal value.

Tested: Browser and redfishtool
Command test: redfishtool -A Basic -S Always --rhost=$bmc_ip -u
$bmc_user -p $bmc_password Chassis -I 1 Power

Redmine ID: #2145.

Change-Id: Ifd4a7495c216f894f46610c02d3e8a8e3988dfaa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Thermal and Power: Correct @odata.id information

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/ae95b0db60e5e680819c9f9b0c6d61caf66b14cf

Allocate @odata.id of schema in correct way.
Sensor module is general interface not used for specific schema.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Power
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Thermal

Redmine ID: #2145 & #2146

Change-Id: I265bbb366c323f39fb6d4ac4f7cccfed4382e98d
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Correct @odata.id for specific Chassis sub-node.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/3eaa53a395ad9275042893413cbefc78f52310e5

Currently there are Thermal and Power sub-nodes of Chassis node, correct
@odata.id information for each sub-node in JSON payload.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Thermal -I 1
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Power -I 1

Change-Id: I2f831ed40926e85c0b6d1cfa7d759eb0b9321daa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>
Signed-off-by: Jennifer Lee <jennifer1.lee@intel.com>
H A Dpower.hpp2474adfa Wed Sep 05 18:31:16 CDT 2018 Ed Tanous <ed.tanous@intel.com> Chassis: Power: Support get PowerSupply and Voltages
sensors information.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/a20f8b17c1efb92b9a8e95e8867d945bc6177804

Sensor module adds sensorType:"power" to retrieve power supply sensor
information.
This applicable to Power schema version 1.2.1

Limit:
- Not retrieve PowerControl information yet.
- Need to get UpperThresholdFatal and LowerThresholdFatal value.

Tested: Browser and redfishtool
Command test: redfishtool -A Basic -S Always --rhost=$bmc_ip -u
$bmc_user -p $bmc_password Chassis -I 1 Power

Redmine ID: #2145.

Change-Id: Ifd4a7495c216f894f46610c02d3e8a8e3988dfaa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Thermal and Power: Correct @odata.id information

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/ae95b0db60e5e680819c9f9b0c6d61caf66b14cf

Allocate @odata.id of schema in correct way.
Sensor module is general interface not used for specific schema.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Power
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Thermal

Redmine ID: #2145 & #2146

Change-Id: I265bbb366c323f39fb6d4ac4f7cccfed4382e98d
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Correct @odata.id for specific Chassis sub-node.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/3eaa53a395ad9275042893413cbefc78f52310e5

Currently there are Thermal and Power sub-nodes of Chassis node, correct
@odata.id information for each sub-node in JSON payload.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Thermal -I 1
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Power -I 1

Change-Id: I2f831ed40926e85c0b6d1cfa7d759eb0b9321daa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>
Signed-off-by: Jennifer Lee <jennifer1.lee@intel.com>
H A Dchassis.hpp2474adfa Wed Sep 05 18:31:16 CDT 2018 Ed Tanous <ed.tanous@intel.com> Chassis: Power: Support get PowerSupply and Voltages
sensors information.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/a20f8b17c1efb92b9a8e95e8867d945bc6177804

Sensor module adds sensorType:"power" to retrieve power supply sensor
information.
This applicable to Power schema version 1.2.1

Limit:
- Not retrieve PowerControl information yet.
- Need to get UpperThresholdFatal and LowerThresholdFatal value.

Tested: Browser and redfishtool
Command test: redfishtool -A Basic -S Always --rhost=$bmc_ip -u
$bmc_user -p $bmc_password Chassis -I 1 Power

Redmine ID: #2145.

Change-Id: Ifd4a7495c216f894f46610c02d3e8a8e3988dfaa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Thermal and Power: Correct @odata.id information

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/ae95b0db60e5e680819c9f9b0c6d61caf66b14cf

Allocate @odata.id of schema in correct way.
Sensor module is general interface not used for specific schema.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Power
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Thermal

Redmine ID: #2145 & #2146

Change-Id: I265bbb366c323f39fb6d4ac4f7cccfed4382e98d
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Correct @odata.id for specific Chassis sub-node.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/3eaa53a395ad9275042893413cbefc78f52310e5

Currently there are Thermal and Power sub-nodes of Chassis node, correct
@odata.id information for each sub-node in JSON payload.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Thermal -I 1
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Power -I 1

Change-Id: I2f831ed40926e85c0b6d1cfa7d759eb0b9321daa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>
Signed-off-by: Jennifer Lee <jennifer1.lee@intel.com>
H A Dsensors.hpp2474adfa Wed Sep 05 18:31:16 CDT 2018 Ed Tanous <ed.tanous@intel.com> Chassis: Power: Support get PowerSupply and Voltages
sensors information.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/a20f8b17c1efb92b9a8e95e8867d945bc6177804

Sensor module adds sensorType:"power" to retrieve power supply sensor
information.
This applicable to Power schema version 1.2.1

Limit:
- Not retrieve PowerControl information yet.
- Need to get UpperThresholdFatal and LowerThresholdFatal value.

Tested: Browser and redfishtool
Command test: redfishtool -A Basic -S Always --rhost=$bmc_ip -u
$bmc_user -p $bmc_password Chassis -I 1 Power

Redmine ID: #2145.

Change-Id: Ifd4a7495c216f894f46610c02d3e8a8e3988dfaa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Thermal and Power: Correct @odata.id information

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/ae95b0db60e5e680819c9f9b0c6d61caf66b14cf

Allocate @odata.id of schema in correct way.
Sensor module is general interface not used for specific schema.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Power
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Thermal

Redmine ID: #2145 & #2146

Change-Id: I265bbb366c323f39fb6d4ac4f7cccfed4382e98d
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Correct @odata.id for specific Chassis sub-node.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/3eaa53a395ad9275042893413cbefc78f52310e5

Currently there are Thermal and Power sub-nodes of Chassis node, correct
@odata.id information for each sub-node in JSON payload.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Thermal -I 1
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Power -I 1

Change-Id: I2f831ed40926e85c0b6d1cfa7d759eb0b9321daa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>
Signed-off-by: Jennifer Lee <jennifer1.lee@intel.com>
/openbmc/bmcweb/redfish-core/include/
H A Dredfish.hpp2474adfa Wed Sep 05 18:31:16 CDT 2018 Ed Tanous <ed.tanous@intel.com> Chassis: Power: Support get PowerSupply and Voltages
sensors information.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/a20f8b17c1efb92b9a8e95e8867d945bc6177804

Sensor module adds sensorType:"power" to retrieve power supply sensor
information.
This applicable to Power schema version 1.2.1

Limit:
- Not retrieve PowerControl information yet.
- Need to get UpperThresholdFatal and LowerThresholdFatal value.

Tested: Browser and redfishtool
Command test: redfishtool -A Basic -S Always --rhost=$bmc_ip -u
$bmc_user -p $bmc_password Chassis -I 1 Power

Redmine ID: #2145.

Change-Id: Ifd4a7495c216f894f46610c02d3e8a8e3988dfaa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Thermal and Power: Correct @odata.id information

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/ae95b0db60e5e680819c9f9b0c6d61caf66b14cf

Allocate @odata.id of schema in correct way.
Sensor module is general interface not used for specific schema.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Power
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis -I 1 Thermal

Redmine ID: #2145 & #2146

Change-Id: I265bbb366c323f39fb6d4ac4f7cccfed4382e98d
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>

Chassis: Correct @odata.id for specific Chassis sub-node.

cherry-picked from:
https://github.com/ampere-openbmc/bmcweb/commit/3eaa53a395ad9275042893413cbefc78f52310e5

Currently there are Thermal and Power sub-nodes of Chassis node, correct
@odata.id information for each sub-node in JSON payload.

Tested: Browser and redfishtool
Command test:
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Thermal -I 1
- redfishtool -A Basic -S Always --rhost=$bmc_ip -u $bmc_user -p
$bmc_password Chassis Power -I 1

Change-Id: I2f831ed40926e85c0b6d1cfa7d759eb0b9321daa
Signed-off-by: Tung Vu <tung.vu@amperecomputing.com>
Signed-off-by: Jennifer Lee <jennifer1.lee@intel.com>