/openbmc/linux/drivers/power/supply/ |
H A D | ab8500-bm.h | 0e8b903b Fri Feb 25 17:27:56 CST 2022 Linus Walleij <linus.walleij@linaro.org> power: supply: ab8500: Standardize alert mode charging
The AB8500 code is using a special current and voltage setting when the battery is in "alert mode", i.e. when it is starting to go outside normal operating conditions so it is too cold or too hot. This makes sense as a way for the charging algorithm to deal with hostile environments.
Add the needed members to the struct power_supply_battery_info, and switch the AB8500 charging code over to using this.
Reviewed-by: Matti Vaittineen <matti.vaittinen@fi.rohmeurope.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
H A D | ab8500_chargalg.c | 0e8b903b Fri Feb 25 17:27:56 CST 2022 Linus Walleij <linus.walleij@linaro.org> power: supply: ab8500: Standardize alert mode charging
The AB8500 code is using a special current and voltage setting when the battery is in "alert mode", i.e. when it is starting to go outside normal operating conditions so it is too cold or too hot. This makes sense as a way for the charging algorithm to deal with hostile environments.
Add the needed members to the struct power_supply_battery_info, and switch the AB8500 charging code over to using this.
Reviewed-by: Matti Vaittineen <matti.vaittinen@fi.rohmeurope.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
H A D | ab8500_bmdata.c | 0e8b903b Fri Feb 25 17:27:56 CST 2022 Linus Walleij <linus.walleij@linaro.org> power: supply: ab8500: Standardize alert mode charging
The AB8500 code is using a special current and voltage setting when the battery is in "alert mode", i.e. when it is starting to go outside normal operating conditions so it is too cold or too hot. This makes sense as a way for the charging algorithm to deal with hostile environments.
Add the needed members to the struct power_supply_battery_info, and switch the AB8500 charging code over to using this.
Reviewed-by: Matti Vaittineen <matti.vaittinen@fi.rohmeurope.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
H A D | power_supply_core.c | 0e8b903b Fri Feb 25 17:27:56 CST 2022 Linus Walleij <linus.walleij@linaro.org> power: supply: ab8500: Standardize alert mode charging
The AB8500 code is using a special current and voltage setting when the battery is in "alert mode", i.e. when it is starting to go outside normal operating conditions so it is too cold or too hot. This makes sense as a way for the charging algorithm to deal with hostile environments.
Add the needed members to the struct power_supply_battery_info, and switch the AB8500 charging code over to using this.
Reviewed-by: Matti Vaittineen <matti.vaittinen@fi.rohmeurope.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
/openbmc/linux/include/linux/ |
H A D | power_supply.h | 0e8b903b Fri Feb 25 17:27:56 CST 2022 Linus Walleij <linus.walleij@linaro.org> power: supply: ab8500: Standardize alert mode charging
The AB8500 code is using a special current and voltage setting when the battery is in "alert mode", i.e. when it is starting to go outside normal operating conditions so it is too cold or too hot. This makes sense as a way for the charging algorithm to deal with hostile environments.
Add the needed members to the struct power_supply_battery_info, and switch the AB8500 charging code over to using this.
Reviewed-by: Matti Vaittineen <matti.vaittinen@fi.rohmeurope.com> Signed-off-by: Linus Walleij <linus.walleij@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|