Searched full:liquid (Results 1 – 25 of 42) sorted by relevance
12
12 description: A critical level liquid leak has been detected.14 A liquid leak has been detected at a critical level by27 description: A warning level liquid leak has been detected.29 A liquid leak has been detected at a warning level by
12 Liquid, enumerator 24 {PumpType::Liquid, "Liquid"},
99 "CoolingSubsystem": "The entire cooling, or air and liquid, subsystem.",111 "LiquidInlet": "The liquid inlet point of the chassis.",112 "LiquidOutlet": "The liquid outlet point of the chassis.",
386 …mental conditions present. For example, liquid inlet temperature can be adjusted based on the ava…397 …mental conditions present. For example, liquid inlet temperature can be adjusted based on the ava…
178 "LiquidFlow": "Liquid flow (L/s).",179 "LiquidFlowLPM": "Liquid flow (L/min).",180 "LiquidLevel": "Liquid level (cm).",204 …"LiquidFlow": "This value shall indicate a measurement of a volume of liquid per unit of time, in …205 …"LiquidFlowLPM": "This value shall indicate a measurement of a volume of liquid per unit of time, …349 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava…358 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava…
301 "description": "The rated liquid flow (L/min) for this cooling loop.",302 …"longDescription": "This property shall contain the rated liquid flow, in liters per minute units,…
54 <Annotation Term="OData.Description" String="The `CoolantConnector` schema describes a liquid coolant connector, including any associated instrumentation."/>108 <Annotation Term="OData.Description" String="The rated liquid flow (L/min) for this loop interface."/>109 <Annotation Term="OData.LongDescription" String="This property shall contain the rated liquid flow, in liters per minute units, for this loop interface."/>115 <Annotation Term="OData.Description" String="The pressure (kPa) at which the rated liquid flow is valid."/>116 <Annotation Term="OData.LongDescription" String="This property shall contain the pressure, in kilopascal units, that the rated liquid flow is valid for this connector."/>152 <Annotation Term="OData.Description" String="The liquid flow (L/min)."/>153 <Annotation Term="OData.LongDescription" String="This property shall contain the liquid flow rate, in liters per minute units, for this coolant connector. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Sensor` with the `ReadingType` property containing the value `LiquidFlowLPM`."/>279 <Annotation Term="OData.Description" String="The desired liquid flow rate (L/min)."/>280 <Annotation Term="OData.LongDescription" String="This property shall contain the desired liquid flow rate, in liters per minute units, of this coolant connector. The value of the `DataSourceUri` property, if present, shall reference a resource of type `Control` with the `ControlType` property containing the value `LiquidFlowLPM`. This property shall only be present for secondary coolant connectors. Services may automatically change other controls if a client attempts to enable this control to prevent conflicts."/>
39 <Annotation Term="OData.Description" String="The liquid inlet point of the chassis."/>50 <Annotation Term="OData.Description" String="The liquid outlet point of the chassis."/>261 … <Annotation Term="OData.Description" String="The entire cooling, or air and liquid, subsystem."/>
234 <Member Name="Liquid">235 <Annotation Term="OData.Description" String="A water or liquid pump."/>
7 title: LG LG4573 TFT Liquid Crystal Display with SPI control bus
32 :Type: LCD Controller (Liquid Crystal Display Controller)
32 :Type: LCD (Liquid Crystal Display)
19 all-in-one CPU liquid coolers. Three sensors are available: fan speed, pump
59 and an estimation of the dissipated/absorbed power in the liquid cooling loop.
73 To calculate the liquid flow in Liters Per Minute.
253 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava…258 … environmental conditions. For example, liquid inlet temperature can be adjusted based on the ava…570 <Annotation Term="OData.Description" String="Liquid level (cm)."/>603 <Annotation Term="OData.Description" String="Liquid flow (L/s)."/>604 …cription" String="This value shall indicate a measurement of a volume of liquid per unit of time, …616 <Annotation Term="OData.Description" String="Liquid flow (L/min)."/>617 …cription" String="This value shall indicate a measurement of a volume of liquid per unit of time, …
412 UCHAR ucLiquid1_I2C_address; /*Liquid */443 UCHAR ucLiquid1_I2C_address; //Liquid
27 * Focusrite Liquid Saffire 56
1566 * Liquid Crystal Display (LCD) control registers1569 * LCCR0 Liquid Crystal Display (LCD) Control Register 01574 * LCSR Liquid Crystal Display (LCD) Status Register1580 * DBAR1 Liquid Crystal Display (LCD) Direct Memory Access1582 * DCAR1 Liquid Crystal Display (LCD) Direct Memory Access1584 * DBAR2 Liquid Crystal Display (LCD) Direct Memory Access1586 * DCAR2 Liquid Crystal Display (LCD) Direct Memory Access1588 * LCCR1 Liquid Crystal Display (LCD) Control Register 11594 * LCCR2 Liquid Crystal Display (LCD) Control Register 21600 * LCCR3 Liquid Crystal Display (LCD) Control Register 3