| /openbmc/bmcweb/redfish-core/schema/dmtf/json-schema/ |
| H A D | CoolingUnit.v1_4_0.json | 48 "All": "Export all configuration data for this equipment including OEM components.", 49 …t configuration data associated with the cooling unit functions and subsystems of this equipment.", 50 … "Manager": "Export configuration data associated with the manager of the equipment.", 51 …associated with the user accounts and external account services of the manager for this equipment." 54 …l": "The service shall export all available configuration data from the equipment including OEM co… 55 …t configuration data associated with the cooling unit functions and subsystems of this equipment.", 56 …er": "The service shall export configuration data associated with any managers of this equipment.", 57 …nts": "The service shall export configuration data associated with any managers for the equipment." 122 "description": "The user-assigned asset tag for this equipment.", 123 …user-assigned asset tag, which is an identifying string that tracks the equipment for inventory pu… [all …]
|
| H A D | PowerDistribution.v1_5_0.json | 48 "All": "Export all configuration data for this equipment including OEM components.", 49 … "Manager": "Export configuration data associated with the manager of the equipment.", 50 …ssociated with the user accounts and external account services of the manager for this equipment.", 51 …ation data associated with the power distribution unit functions and subsystems of this equipment." 54 …l": "The service shall export all available configuration data from the equipment including OEM co… 55 …er": "The service shall export configuration data associated with any managers of this equipment.", 56 …ts": "The service shall export configuration data associated with any managers for the equipment.", 57 …ation data associated with the power distribution unit functions and subsystems of this equipment." 63 …"description": "This action exports the configuration of the equipment in a vendor-specific format… 64 …cription": "This action shall export the specified configuration of the equipment in a vendor-spec… [all …]
|
| H A D | ThermalSubsystem.v1_5_0.json | 96 …dundancy information for the set of coolant connectors attached to this equipment. The values of … 102 "description": "A link to the coolant connectors for this equipment.", 103 …ion of type `CoolantConnectorCollection` that contains the coolant connectors for this equipment.", 133 …"description": "An indication of whether the fans in this equipment are overridden to operate at f… 134 …ongDescription": "This property shall indicate whether the fans in this equipment are overridden t… 144 "description": "A link to the filters for this equipment.", 145 …to a resource collection of type `FilterCollection` that contains the filters for this equipment.", 163 …ating the `LeakDetection` resource under `CoolingUnit` for the relevant equipment is the preferred… 178 "description": "A link to the pumps for this equipment.", 179 …llection of type `PumpCollection` that contains details for the pumps included in this equipment.",
|
| H A D | Pump.v1_2_0.json | 101 "description": "The user-assigned asset tag for this equipment.", 102 …user-assigned asset tag, which is an identifying string that tracks the equipment for inventory pu… 127 "description": "The firmware version of this equipment.", 128 …property shall contain a string describing the firmware version of this equipment as provided by t… 208 "description": "The production or manufacturing date of this equipment.", 210 …cription": "This property shall contain the date of production or manufacture for this equipment.", 298 "description": "The hardware version of this equipment.", 299 …Description": "This property shall contain the hardware version of this equipment as determined by…
|
| H A D | Circuit.v1_8_1.json | 631 …taining the value `Current`. This property shall not be present if the equipment does not include… 644 …taining the value `Current`. This property shall not be present if the equipment does not include… 657 …taining the value `Current`. This property shall not be present if the equipment does not include… 670 …taining the value `Current`. This property shall not be present if the equipment does not include… 705 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include… 718 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include… 731 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include… 744 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include… 757 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include… 770 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include… [all …]
|
| H A D | CoolingLoop.v1_1_0.json | 310 "description": "A link to the primary coolant connectors for this equipment.", 311 …ype `CoolantConnectorCollection` that contains the primary coolant connectors for this equipment.", 338 "description": "A link to the secondary coolant connectors for this equipment.", 339 …e `CoolantConnectorCollection` that contains the secondary coolant connectors for this equipment.", 415 "description": "A link to the chassis that contains this equipment.", 421 "description": "A link to the facility that contains this equipment.", 422 … link to a resource of type `Facility` that represents the facility that contains this equipment.", 426 … "description": "An array of links to the managers responsible for managing this equipment.", 430 …y of links to resources of type `Manager` that represent the managers that manage this equipment.",
|
| H A D | LeakDetection.v1_1_0.json | 36 …on` schema contains definitions for reporting leaks in liquid cooling systems or other equipment.", 86 "description": "The groups of leak detection equipment.", 124 "description": "A group of leak detection equipment.", 125 …"longDescription": "This object shall contain a group of leak detection equipment that reports a u… 155 …perty shall contain the name used to describe this group of leak detectors and related equipment.",
|
| H A D | Thermal.v1_7_3.json | 52 … indication of whether this device can be inserted or removed while the equipment is in operation.… 53 …equipment otherwise remains in its current operational state. Hot-pluggable devices can become op… 385 …escription": "Adjusted maximum allowable operating temperature for this equipment based on the cur… 386 …l indicate the adjusted maximum allowable operating temperature for the equipment monitored by thi… 396 …escription": "Adjusted minimum allowable operating temperature for this equipment based on the cur… 397 …l indicate the adjusted minimum allowable operating temperature for the equipment monitored by thi… 466 "description": "Maximum allowable operating temperature for this equipment.", 467 …erty shall indicate the maximum allowable operating temperature for the equipment monitored by thi… 493 "description": "Minimum allowable operating temperature for this equipment.", 494 …erty shall indicate the minimum allowable operating temperature for the equipment monitored by thi…
|
| H A D | LeakDetector.v1_5_0.json | 209 …ll contain a description of the affected component or region within the equipment to which this le… 223 …perty shall contain a description of the usage or sub-region within the equipment to which this le… 366 …ll contain a description of the affected component or region within the equipment to which this le… 380 …perty shall contain a description of the usage or sub-region within the equipment to which this le… 473 "ForceOff": "Forcefully shut down the device, equipment, or system.", 474 "GracefulShutdown": "Gracefully shut down the device, equipment, or system.", 478 …"ForceOff": "This value shall indicate that the associated device, equipment, or system monitored … 479 …acefulShutdown": "This value shall indicate that the associated device, equipment, or system monit…
|
| H A D | ThermalEquipment.v1_2_0.json | 57 …"description": "The `ThermalEquipment` schema represents the set of cooling equipment managed by a… 58 …"longDescription": "This resource shall represent the set of cooling equipment for a Redfish imple… 98 … "description": "The redundancy information for cooling loops attached to this equipment.", 102 …in redundancy information for the set of cooling loops attached to this equipment. The values of …
|
| H A D | Filter.v1_1_0.json | 103 … indication of whether this device can be inserted or removed while the equipment is in operation.… 104 …equipment otherwise remains in its current operational state. Devices indicated as hot-pluggable …
|
| H A D | Heater.v1_0_2.json | 88 … indication of whether this device can be inserted or removed while the equipment is in operation.… 89 …equipment otherwise remains in its current operational state. Hot-pluggable devices can become op…
|
| /openbmc/bmcweb/redfish-core/schema/dmtf/csdl/ |
| H A D | CoolingUnit_v1.xml | 123 …OData.Description" String="This action exports the configuration of the equipment in a vendor-spec… 124 …on" String="This action shall export the specified configuration of the equipment in a vendor-spec… 131 …<Annotation Term="OData.Description" String="The components of the equipment for which to export c… 132 …ion" String="This parameter shall contain an array of components of the equipment for which to exp… 135 …<Annotation Term="OData.Description" String="The OEM-specific components of the equipment for whic… 136 …This parameter shall contain an array of OEM-specific components of the equipment for which to exp… 164 … <Annotation Term="OData.Description" String="The type of equipment this resource represents."/> 165 …"OData.LongDescription" String="This property shall contain the type of equipment this resource re… 175 … <Annotation Term="OData.Description" String="The cooling capacity (W) of this equipment."/> 176 …erty shall contain the manufacturer-provided cooling capacity, in watt units, of this equipment."/> [all …]
|
| H A D | PowerDistribution_v1.xml | 107 …OData.Description" String="This action exports the configuration of the equipment in a vendor-spec… 108 …on" String="This action shall export the specified configuration of the equipment in a vendor-spec… 115 …<Annotation Term="OData.Description" String="The components of the equipment for which to export c… 116 …ion" String="This parameter shall contain an array of components of the equipment for which to exp… 119 …<Annotation Term="OData.Description" String="The OEM-specific components of the equipment for whic… 120 …This parameter shall contain an array of OEM-specific components of the equipment for which to exp… 149 … <Annotation Term="OData.Description" String="The type of equipment this resource represents."/> 150 …"OData.LongDescription" String="This property shall contain the type of equipment this resource re… 155 … <Annotation Term="OData.Description" String="The product model number of this equipment."/> 156 …ring="This property shall contain the manufacturer-provided model information of this equipment."/> [all …]
|
| H A D | ThermalSubsystem_v1.xml | 179 …Annotation Term="OData.Description" String="A link to the coolant connectors for this equipment."/> 180 …on of type `CoolantConnectorCollection` that contains the coolant connectors for this equipment."/> 205 …dundancy information for the set of coolant connectors attached to this equipment. The values of … 209 <Annotation Term="OData.Description" String="A link to the pumps for this equipment."/> 210 …lection of type `PumpCollection` that contains details for the pumps included in this equipment."/> 216 …ating the `LeakDetection` resource under `CoolingUnit` for the relevant equipment is the preferred… 236 … of `LeakDetection` in single-chassis equipments as compared to multi-chassis cooling equipment."/> 247 <Annotation Term="OData.Description" String="A link to the filters for this equipment."/> 248 …o a resource collection of type `FilterCollection` that contains the filters for this equipment."/> 261 …m="OData.Description" String="An indication of whether the fans in this equipment are overridden t… [all …]
|
| H A D | LeakDetection_v1.xml | 44 …n` schema contains definitions for reporting leaks in liquid cooling systems or other equipment."/> 83 <Annotation Term="OData.Description" String="The groups of leak detection equipment."/> 108 <Annotation Term="OData.Description" String="A group of leak detection equipment."/> 109 …escription" String="This object shall contain a group of leak detection equipment that reports a u… 113 …erty shall contain the name used to describe this group of leak detectors and related equipment."/>
|
| H A D | CoolingLoop_v1.xml | 154 …on Term="OData.Description" String="A link to the primary coolant connectors for this equipment."/> 155 …pe `CoolantConnectorCollection` that contains the primary coolant connectors for this equipment."/> 160 … Term="OData.Description" String="A link to the secondary coolant connectors for this equipment."/> 161 … `CoolantConnectorCollection` that contains the secondary coolant connectors for this equipment."/> 233 …<Annotation Term="OData.Description" String="A link to the chassis that contains this equipment."/> 239 …Annotation Term="OData.Description" String="A link to the facility that contains this equipment."/> 240 …link to a resource of type `Facility` that represents the facility that contains this equipment."/> 245 ….Description" String="An array of links to the managers responsible for managing this equipment."/> 246 … of links to resources of type `Manager` that represent the managers that manage this equipment."/>
|
| /openbmc/openbmc/poky/meta/files/common-licenses/ |
| H A D | DEC-3-Clause | 1 Copyright 1997 Digital Equipment Corporation. 15 Equipment Corporation. Neither the "Digital Equipment Corporation" 16 name nor any trademark or logo of Digital Equipment Corporation may be 18 the prior written permission of Digital Equipment Corporation.
|
| H A D | HP-1989 | 3 Digital Equipment Corporation, Maynard, Mass. 11 Company, Microsoft, or Digital Equipment Corporation be used in 15 Equipment Corporation makes any representations about the
|
| H A D | HPND-DEC | 2 DIGITAL EQUIPMENT CORPORATION 6 …CHANGE WITHOUT NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL EQUIPMENT CORPORATION. 20 and that the name of Digital Equipment Corporation not be
|
| /openbmc/bmcweb/redfish-core/schema/dmtf/json-schema-installed/ |
| H A D | ThermalSubsystem.v1_5_0.json | 96 …dundancy information for the set of coolant connectors attached to this equipment. The values of … 102 "description": "A link to the coolant connectors for this equipment.", 103 …ion of type `CoolantConnectorCollection` that contains the coolant connectors for this equipment.", 133 …"description": "An indication of whether the fans in this equipment are overridden to operate at f… 134 …ongDescription": "This property shall indicate whether the fans in this equipment are overridden t… 144 "description": "A link to the filters for this equipment.", 145 …to a resource collection of type `FilterCollection` that contains the filters for this equipment.", 163 …ating the `LeakDetection` resource under `CoolingUnit` for the relevant equipment is the preferred… 178 "description": "A link to the pumps for this equipment.", 179 …llection of type `PumpCollection` that contains details for the pumps included in this equipment.",
|
| H A D | Thermal.v1_7_3.json | 52 … indication of whether this device can be inserted or removed while the equipment is in operation.… 53 …equipment otherwise remains in its current operational state. Hot-pluggable devices can become op… 385 …escription": "Adjusted maximum allowable operating temperature for this equipment based on the cur… 386 …l indicate the adjusted maximum allowable operating temperature for the equipment monitored by thi… 396 …escription": "Adjusted minimum allowable operating temperature for this equipment based on the cur… 397 …l indicate the adjusted minimum allowable operating temperature for the equipment monitored by thi… 466 "description": "Maximum allowable operating temperature for this equipment.", 467 …erty shall indicate the maximum allowable operating temperature for the equipment monitored by thi… 493 "description": "Minimum allowable operating temperature for this equipment.", 494 …erty shall indicate the minimum allowable operating temperature for the equipment monitored by thi…
|
| /openbmc/qemu/hw/ppc/ |
| H A D | prep_systemio.c | 51 uint8_t equipment; /* 0x080c */ member 138 /* PORT 080C -- Equipment */ 151 trace_prep_systemio_read(addr, s->equipment); in prep_port080c_read() 152 return s->equipment; in prep_port080c_read() 290 DEFINE_PROP_UINT8("equipment", PrepSystemIoState, equipment, 0),
|
| /openbmc/bmcweb/redfish-core/schema/dmtf/installed/ |
| H A D | ThermalSubsystem_v1.xml | 179 <Annotation Term="OData.Description" String="A link to the coolant connectors for this equipment."/> 180 <Annotation Term="OData.LongDescription" String="This property shall contain a link to a resource collection of type `CoolantConnectorCollection` that contains the coolant connectors for this equipment."/> 205 <Annotation Term="OData.LongDescription" String="This property shall contain redundancy information for the set of coolant connectors attached to this equipment. The values of the `RedundancyGroup` array shall reference resources of type `CoolantConnector`."/> 209 <Annotation Term="OData.Description" String="A link to the pumps for this equipment."/> 210 <Annotation Term="OData.LongDescription" String="This property shall contain a link to a resource collection of type `PumpCollection` that contains details for the pumps included in this equipment."/> 216 <Annotation Term="OData.LongDescription" String="This property shall contain a link to a resource of type `LeakDetection`. This link should be used when the leak detection capabilities are tied to, or are internal to, a particular `Chassis`. For detection capabilities that are tied to a `CoolingUnit` resource, which may span multiple `Chassis` resources, populating the `LeakDetection` resource under `CoolingUnit` for the relevant equipment is the preferred approach."/> 236 <Annotation Term="OData.Description" String="This version was created to clarify the usage of `LeakDetection` in single-chassis equipments as compared to multi-chassis cooling equipment."/> 247 <Annotation Term="OData.Description" String="A link to the filters for this equipment."/> 248 <Annotation Term="OData.LongDescription" String="This property shall contain a link to a resource collection of type `FilterCollection` that contains the filters for this equipment."/> 261 <Annotation Term="OData.Description" String="An indication of whether the fans in this equipment ar [all...] |
| /openbmc/phosphor-dbus-interfaces/yaml/xyz/openbmc_project/Inventory/Decorator/ |
| H A D | CLEI.interface.yaml | 2 Implement to indicate an item with a defined Common Language Equipment
|