Home
last modified time | relevance | path

Searched full:classified (Results 1 – 25 of 122) sorted by relevance

12345

/openbmc/linux/drivers/net/ethernet/microchip/vcap/
H A Dvcap_ag_api.h60 * Keys ending in _CLS are classified frame data
84 * Classified DEI
92 * Classified PCP
109 * Classified VID
184 * Classified ISDX
186 * Set if classified ISDX > 0
287 * is taken from classified results (VID, DSCP) and frame (SPORT, DPORT, ETYPE,
316 * Classified Policy Association Group: chains rules from IS1/CLM to IS2
340 * Classified RTP_ID
510 * Controls the classified VID: 0: VID_NONE: No action. 1: VID_ADD: New VID =
[all …]
/openbmc/linux/drivers/net/ethernet/microchip/lan966x/
H A Dlan966x_ifh.h54 /* Classified DSCP value of frame */
75 /* Stagd flag and classified TCI of frame (PCP/DEI/VID) */
78 /* Classified internal priority for queuing */
98 /* ISDX as classified by S1 */
110 /* Classified internal priority for resourcemgt, tagging etc */
H A Dlan966x_port.c476 /* Map the values only if it is enabled otherwise will be the classified in lan966x_port_qos_pcp_rewr_set()
519 /* Map each classified Qos class and DP to classified DSCP value */ in lan966x_port_qos_dscp_rewr_set()
/openbmc/linux/drivers/net/ethernet/microchip/sparx5/
H A Dsparx5_dcb.c188 * not indicate DP level, so we map classified QoS class to in sparx5_dcb_app_update()
189 * classified DSCP, for each classified DP level. Rewrite of in sparx5_dcb_app_update()
217 * classified DSCP will then be zero for all classified in sparx5_dcb_app_update()
399 /* Enable DSCP classification based on classified QoS class and in sparx5_dcb_init()
H A Dsparx5_port.c1173 /* Use mapping table, with classified QoS as index, to map QoS and DP in sparx5_port_qos_pcp_rewr_set()
1174 * to tagged PCP and DEI, if PCP is trusted. Otherwise use classified in sparx5_port_qos_pcp_rewr_set()
1175 * PCP. Classified PCP equals frame PCP. in sparx5_port_qos_pcp_rewr_set()
1193 /* Rewrite PCP and DEI, for each classified QoS class and DP in sparx5_port_qos_pcp_rewr_set()
1266 /* On egress, rewrite DSCP value to either classified DSCP or frame in sparx5_port_qos_dscp_rewr_set()
1267 * DSCP. If enabled; classified DSCP, if disabled; frame DSCP. in sparx5_port_qos_dscp_rewr_set()
1276 /* On ingress, map each classified QoS class and DP to classified DSCP in sparx5_port_qos_dscp_rewr_set()
/openbmc/linux/net/dsa/
H A Dtag_ocelot.c129 * 802.1Q header does not (the classified VLAN only becomes visible on in ocelot_rcv()
132 * classified VLAN and manually replace the existing 802.1Q header from in ocelot_rcv()
136 * frame to remain unmodified, because the classified VLAN is always in ocelot_rcv()
/openbmc/u-boot/doc/
H A DREADME.t1040-l2switch45 ethsw [port <port_no>] egress tag { [help] | show | pvid | classified } - configure VID source for …
46 Tag's VID could be the frame's classified VID or the PVID of the port
/openbmc/linux/include/linux/
H A Dnetfilter_netdev.h65 * @skb: packet to be classified
72 * On ingress, packets are classified first by tc, then by netfilter.
/openbmc/linux/Documentation/devicetree/bindings/bus/
H A Dti,da850-mstpri.txt5 peripherals classified as masters.
/openbmc/linux/Documentation/ABI/testing/
H A Dsysfs-firmware-opal-sensor-groups7 which are classified based on type of the sensor
/openbmc/linux/Documentation/virt/
H A Dparavirt_ops.rst21 pv_ops operations are classified into three categories:
/openbmc/openbmc/poky/meta/files/common-licenses/
H A DSWL5 …software on behalf of the Department of Defense, the software shall be classified as "Commercial C…
H A DTCL9 …software on behalf of the Department of Defense, the software shall be classified as "Commercial C…
H A DAladdin62classified as "commercial computer software" and "commercial computer software documentation" resp…
/openbmc/linux/Documentation/devicetree/bindings/arm/
H A Darm,coresight-tpiu.yaml18 SoCs tracing needs. These trace components can generally be classified as
H A Darm,coresight-dummy-source.yaml12 SoCs tracing needs. These trace components can generally be classified as
H A Darm,coresight-etb10.yaml18 SoCs tracing needs. These trace components can generally be classified as
H A Darm,coresight-static-funnel.yaml18 SoCs tracing needs. These trace components can generally be classified as
H A Darm,coresight-dummy-sink.yaml12 SoCs tracing needs. These trace components can generally be classified as
H A Darm,coresight-stm.yaml18 SoCs tracing needs. These trace components can generally be classified as
H A Darm,coresight-static-replicator.yaml18 SoCs tracing needs. These trace components can generally be classified as
H A Darm,coresight-catu.yaml18 SoCs tracing needs. These trace components can generally be classified as
/openbmc/linux/net/sched/
H A Dsch_hhf.c19 * Flows are classified into two buckets: non-heavy-hitter and heavy-hitter
20 * buckets. Initially, a new flow starts as non-heavy-hitter. Once classified
44 * susceptible to false positives (non-heavy-hitters mistakenly classified as
59 * Once a flow is classified as heavy-hitter, we also save its per-flow state
/openbmc/linux/Documentation/networking/devlink/
H A Dnetdevsim.rst97 - When a packet enters the device it is classified to a filtering
/openbmc/linux/Documentation/PCI/
H A Dpcieaer-howto.rst102 PCIe errors are classified into two types: correctable errors
116 errors are further classified into non-fatal errors and fatal errors.

12345