Home
last modified time | relevance | path

Searched full:equipment (Results 1 – 25 of 258) sorted by relevance

1234567891011

/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema/
H A DCoolingUnit.v1_1_2.json
H A DPowerDistribution.v1_4_0.json57 "description": "An array of links to the chassis that contain this equipment.",
70 "description": "A link to the facility that contains this equipment.",
71 … link to a resource of type `Facility` that represents the facility that contains this equipment.",
75 … "description": "An array of links to the managers responsible for managing this equipment.",
79 …y of links to resources of type `Manager` that represent the managers that manage this equipment.",
152 "description": "The user-assigned asset tag for this equipment.",
153 …user-assigned asset tag, which is an identifying string that tracks the equipment for inventory pu…
162 "description": "A link to the branch circuits for this equipment.",
163 …urce collection of type `CircuitCollection` that contains the branch circuits for this equipment.",
179 "description": "The type of equipment this resource represents.",
[all …]
H A DPump.v1_1_0.json
H A DCircuit.v1_8_1.json631 …taining the value `Current`. This property shall not be present if the equipment does not include…
644 …taining the value `Current`. This property shall not be present if the equipment does not include…
657 …taining the value `Current`. This property shall not be present if the equipment does not include…
670 …taining the value `Current`. This property shall not be present if the equipment does not include…
705 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include…
718 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include…
731 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include…
744 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include…
757 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include…
770 …ining the value `EnergykWh`. This property shall not be present if the equipment does not include…
[all …]
H A DCoolingLoop.v1_0_3.json296 "description": "A link to the primary coolant connectors for this equipment.",
297 …ype `CoolantConnectorCollection` that contains the primary coolant connectors for this equipment.",
324 "description": "A link to the secondary coolant connectors for this equipment.",
325 …e `CoolantConnectorCollection` that contains the secondary coolant connectors for this equipment.",
388 "description": "A link to the chassis that contains this equipment.",
394 "description": "A link to the facility that contains this equipment.",
395 … link to a resource of type `Facility` that represents the facility that contains this equipment.",
399 … "description": "An array of links to the managers responsible for managing this equipment.",
403 …y of links to resources of type `Manager` that represent the managers that manage this equipment.",
H A DThermalSubsystem.v1_3_2.json
H A DLeakDetection.v1_1_0.json36 …on` schema contains definitions for reporting leaks in liquid cooling systems or other equipment.",
86 "description": "The groups of leak detection equipment.",
124 "description": "A group of leak detection equipment.",
125 …"longDescription": "This object shall contain a group of leak detection equipment that reports a u…
155 …perty shall contain the name used to describe this group of leak detectors and related equipment.",
H A DThermal.v1_7_3.json52 … indication of whether this device can be inserted or removed while the equipment is in operation.…
53equipment otherwise remains in its current operational state. Hot-pluggable devices can become op…
385 …escription": "Adjusted maximum allowable operating temperature for this equipment based on the cur…
386 …l indicate the adjusted maximum allowable operating temperature for the equipment monitored by thi…
396 …escription": "Adjusted minimum allowable operating temperature for this equipment based on the cur…
397 …l indicate the adjusted minimum allowable operating temperature for the equipment monitored by thi…
466 "description": "Maximum allowable operating temperature for this equipment.",
467 …erty shall indicate the maximum allowable operating temperature for the equipment monitored by thi…
493 "description": "Minimum allowable operating temperature for this equipment.",
494 …erty shall indicate the minimum allowable operating temperature for the equipment monitored by thi…
H A DFilter.v1_0_2.json88 … indication of whether this device can be inserted or removed while the equipment is in operation.…
89equipment otherwise remains in its current operational state. Devices indicated as hot-pluggable …
H A DThermalEquipment.v1_1_2.json57 …"description": "The `ThermalEquipment` schema represents the set of cooling equipment managed by a…
58 …"longDescription": "This resource shall represent the set of cooling equipment for a Redfish imple…
98 … "description": "The redundancy information for cooling loops attached to this equipment.",
102 …in redundancy information for the set of cooling loops attached to this equipment. The values of …
/openbmc/bmcweb/redfish-core/schema/dmtf/csdl/
H A DCoolingUnit_v1.xml129 <Annotation Term="OData.Description" String="The type of equipment this resource represents."/>
130 <Annotation Term="OData.LongDescription" String="This property shall contain the type of equipment this resource represents."/>
140 <Annotation Term="OData.Description" String="The cooling capacity (W) of this equipment."/>
141 <Annotation Term="OData.LongDescription" String="This property shall contain the manufacturer-provided cooling capacity, in watt units, of this equipment."/>
145 <Annotation Term="OData.Description" String="The product model number of this equipment."/>
146 <Annotation Term="OData.LongDescription" String="This property shall contain the manufacturer-provided model information of this equipment."/>
150 <Annotation Term="OData.Description" String="The manufacturer of this equipment."/>
151 <Annotation Term="OData.LongDescription" String="This property shall contain the name of the organization responsible for producing the equipment. This organization may be the entity from which the equipment is purchased, but this is not necessarily true."/>
155 <Annotation Term="OData.Description" String="The serial number for this equipment
[all...]
H A DPowerDistribution_v1.xml114 … <Annotation Term="OData.Description" String="The type of equipment this resource represents."/>
115 …"OData.LongDescription" String="This property shall contain the type of equipment this resource re…
120 … <Annotation Term="OData.Description" String="The product model number of this equipment."/>
121 …ring="This property shall contain the manufacturer-provided model information of this equipment."/>
125 <Annotation Term="OData.Description" String="The manufacturer of this equipment."/>
126 …anization responsible for producing the equipment. This organization may be the entity from which…
130 <Annotation Term="OData.Description" String="The serial number for this equipment."/>
131 …ring="This property shall contain a manufacturer-allocated number that identifies the equipment."/>
135 <Annotation Term="OData.Description" String="The part number for this equipment."/>
136 …on" String="This property shall contain the manufacturer-provided part number for the equipment."/>
[all …]
H A DCoolingLoop_v1.xml154 …on Term="OData.Description" String="A link to the primary coolant connectors for this equipment."/>
155 …pe `CoolantConnectorCollection` that contains the primary coolant connectors for this equipment."/>
160 … Term="OData.Description" String="A link to the secondary coolant connectors for this equipment."/>
161 … `CoolantConnectorCollection` that contains the secondary coolant connectors for this equipment."/>
233 …<Annotation Term="OData.Description" String="A link to the chassis that contains this equipment."/>
239 …Annotation Term="OData.Description" String="A link to the facility that contains this equipment."/>
240 …link to a resource of type `Facility` that represents the facility that contains this equipment."/>
245 ….Description" String="An array of links to the managers responsible for managing this equipment."/>
246 … of links to resources of type `Manager` that represent the managers that manage this equipment."/>
H A DPump_v1.xml160 <Annotation Term="OData.Description" String="The hardware version of this equipment."/>
161 <Annotation Term="OData.LongDescription" String="This property shall contain the hardware version of this equipment as determined by the vendor or supplier."/>
165 <Annotation Term="OData.Description" String="The firmware version of this equipment."/>
166 <Annotation Term="OData.LongDescription" String="This property shall contain a string describing the firmware version of this equipment as provided by the manufacturer."/>
170 <Annotation Term="OData.Description" String="The production or manufacturing date of this equipment."/>
171 <Annotation Term="OData.LongDescription" String="This property shall contain the date of production or manufacture for this equipment."/>
175 <Annotation Term="OData.Description" String="The user-assigned asset tag for this equipment."/>
176 <Annotation Term="OData.LongDescription" String="This property shall contain the user-assigned asset tag, which is an identifying string that tracks the equipment for inventory purposes."/>
H A DLeakDetection_v1.xml44 <Annotation Term="OData.Description" String="The `LeakDetection` schema contains definitions for reporting leaks in liquid cooling systems or other equipment."/>
82 <Annotation Term="OData.Description" String="The groups of leak detection equipment."/>
107 <Annotation Term="OData.Description" String="A group of leak detection equipment."/>
108 <Annotation Term="OData.LongDescription" String="This object shall contain a group of leak detection equipment that reports a unified status."/>
112 <Annotation Term="OData.LongDescription" String="This property shall contain the name used to describe this group of leak detectors and related equipment."/>
/openbmc/openbmc/poky/meta/files/common-licenses/
H A DDEC-3-Clause1 Copyright 1997 Digital Equipment Corporation.
15 Equipment Corporation. Neither the "Digital Equipment Corporation"
16 name nor any trademark or logo of Digital Equipment Corporation may be
18 the prior written permission of Digital Equipment Corporation.
H A DHP-19893 Digital Equipment Corporation, Maynard, Mass.
11 Company, Microsoft, or Digital Equipment Corporation be used in
15 Equipment Corporation makes any representations about the
H A DHPND-DEC2 DIGITAL EQUIPMENT CORPORATION
6 …CHANGE WITHOUT NOTICE AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY DIGITAL EQUIPMENT CORPORATION.
20 and that the name of Digital Equipment Corporation not be
/openbmc/linux/drivers/net/pse-pd/
H A DKconfig3 # Ethernet Power Sourcing Equipment drivers
7 bool "Ethernet Power Sourcing Equipment Support"
9 Generic Power Sourcing Equipment Controller support.
20 Sourcing Equipment without automatic classification support. For
/openbmc/qemu/hw/ppc/
H A Dprep_systemio.c51 uint8_t equipment; /* 0x080c */ member
138 /* PORT 080C -- Equipment */
151 trace_prep_systemio_read(addr, s->equipment); in prep_port080c_read()
152 return s->equipment; in prep_port080c_read()
290 DEFINE_PROP_UINT8("equipment", PrepSystemIoState, equipment, 0),
/openbmc/bmcweb/redfish-core/schema/dmtf/json-schema-installed/
H A DThermalSubsystem.v1_3_2.json
H A DThermal.v1_7_3.json52 … indication of whether this device can be inserted or removed while the equipment is in operation.…
53equipment otherwise remains in its current operational state. Hot-pluggable devices can become op…
385 …escription": "Adjusted maximum allowable operating temperature for this equipment based on the cur…
386 …l indicate the adjusted maximum allowable operating temperature for the equipment monitored by thi…
396 …escription": "Adjusted minimum allowable operating temperature for this equipment based on the cur…
397 …l indicate the adjusted minimum allowable operating temperature for the equipment monitored by thi…
466 "description": "Maximum allowable operating temperature for this equipment.",
467 …erty shall indicate the maximum allowable operating temperature for the equipment monitored by thi…
493 "description": "Minimum allowable operating temperature for this equipment.",
494 …erty shall indicate the minimum allowable operating temperature for the equipment monitored by thi…
/openbmc/linux/drivers/net/ethernet/dec/
H A DKconfig3 # Digital Equipment Inc network device configuration
7 bool "Digital Equipment devices"
/openbmc/linux/Documentation/devicetree/bindings/net/pse-pd/
H A Dpse-controller.yaml7 title: Power Sourcing Equipment (PSE).
9 description: Binding for the Power Sourcing Equipment (PSE) as defined in the
/openbmc/linux/Documentation/userspace-api/media/dvb/
H A Dfrontend.rst28 - Satellite Equipment Control (SEC) [#f1]_.
41 On Satellite systems, the API support for the Satellite Equipment

1234567891011