1 #pragma once 2 /**************************************************************** 3 * READ THIS WARNING FIRST 4 * This is an auto-generated header which contains definitions 5 * for Redfish DMTF defined messages. 6 * DO NOT modify this registry outside of running the 7 * parse_registries.py script. The definitions contained within 8 * this file are owned by DMTF. Any modifications to these files 9 * should be first pushed to the relevant registry in the DMTF 10 * github organization. 11 ***************************************************************/ 12 #include "registries.hpp" 13 14 #include <array> 15 16 // clang-format off 17 18 namespace redfish::registries::openbmc 19 { 20 const Header header = { 21 "Copyright 2022 OpenBMC. All rights reserved.", 22 "#MessageRegistry.v1_4_0.MessageRegistry", 23 0, 24 5, 25 0, 26 "OpenBMC Message Registry", 27 "en", 28 "This registry defines the base messages for OpenBMC.", 29 "OpenBMC", 30 "OpenBMC", 31 }; 32 constexpr const char* url = 33 "https://github.com/openbmc/bmcweb/blob/master/redfish-core/include/registries/openbmc.json"; 34 35 constexpr std::array registry = 36 { 37 MessageEntry{ 38 "ADDDCCorrectable", 39 { 40 "Indicates an ADDDC Correctable Error.", 41 "ADDDC Correctable Error.Socket=%1 Channel=%2 DIMM=%3 Rank=%4.", 42 "Warning", 43 4, 44 { 45 "number", 46 "string", 47 "number", 48 "number", 49 }, 50 "None.", 51 }}, 52 MessageEntry{ 53 "AtScaleDebugConnected", 54 { 55 "Indicates At-Scale Debug connection has been established", 56 "At-Scale Debug service is now connected %1", 57 "Critical", 58 1, 59 { 60 "string", 61 }, 62 "None.", 63 }}, 64 MessageEntry{ 65 "AtScaleDebugConnectionFailed", 66 { 67 "Indicates At-Scale Debug connection aborted/failed", 68 "At-Scale Debug connection aborted/failed", 69 "Critical", 70 0, 71 {}, 72 "None.", 73 }}, 74 MessageEntry{ 75 "AtScaleDebugDisconnected", 76 { 77 "Indicates At-Scale Debug connection has ended", 78 "At-Scale Debug service is now disconnected", 79 "OK", 80 0, 81 {}, 82 "None.", 83 }}, 84 MessageEntry{ 85 "AtScaleDebugFeatureDisabled", 86 { 87 "Indicates that At-Scale Debug service is stopped.", 88 "At-Scale Debug service is stopped.", 89 "OK", 90 0, 91 {}, 92 "None.", 93 }}, 94 MessageEntry{ 95 "AtScaleDebugFeatureDisabledAtHardware", 96 { 97 "Indicates that At-Scale Debug disable is detected in hardware.", 98 "At-Scale Debug Feature is disabled in hardware.", 99 "OK", 100 0, 101 {}, 102 "None.", 103 }}, 104 MessageEntry{ 105 "AtScaleDebugFeatureEnabled", 106 { 107 "Indicates that At-Scale Debug service is started.", 108 "At-Scale Debug service is started.", 109 "Critical", 110 0, 111 {}, 112 "None.", 113 }}, 114 MessageEntry{ 115 "AtScaleDebugFeatureEnabledAtHardware", 116 { 117 "Indicates that At-Scale Debug enable is detected in hardware.", 118 "At-Scale Debug Feature is enabled in hardware.", 119 "Critical", 120 0, 121 {}, 122 "None.", 123 }}, 124 MessageEntry{ 125 "AtScaleDebugSpecialUserDisabled", 126 { 127 "Indicates that special user is disabled.", 128 "At-Scale Debug special user is disabled", 129 "OK", 130 0, 131 {}, 132 "None.", 133 }}, 134 MessageEntry{ 135 "AtScaleDebugSpecialUserEnabled", 136 { 137 "Indicates that special user is enabled.", 138 "At-Scale Debug special user is enabled", 139 "Critical", 140 0, 141 {}, 142 "None.", 143 }}, 144 MessageEntry{ 145 "BIOSAttributesChanged", 146 { 147 "Indicates that a set of BIOS Attributes has changed.", 148 "Set of BIOS Attributes changed.", 149 "OK", 150 0, 151 {}, 152 "None.", 153 }}, 154 MessageEntry{ 155 "BIOSBoot", 156 { 157 "Indicates BIOS has transitioned control to the OS Loader.", 158 "BIOS System Boot.", 159 "OK", 160 0, 161 {}, 162 "None.", 163 }}, 164 MessageEntry{ 165 "BIOSFirmwarePanicReason", 166 { 167 "Indicates the reason for BIOS firmware panic.", 168 "BIOS firmware panic occurred due to %1.", 169 "Warning", 170 1, 171 { 172 "string", 173 }, 174 "None.", 175 }}, 176 MessageEntry{ 177 "BIOSFirmwareRecoveryReason", 178 { 179 "Indicates the reason for BIOS firmware recovery.", 180 "BIOS firmware recovery occurred due to %1.", 181 "Warning", 182 1, 183 { 184 "string", 185 }, 186 "None.", 187 }}, 188 MessageEntry{ 189 "BIOSFirmwareResiliencyError", 190 { 191 "Indicates BIOS firmware encountered resilience error.", 192 "BIOS firmware resiliency error. Error reason: %1.", 193 "Critical", 194 1, 195 { 196 "string", 197 }, 198 "None.", 199 }}, 200 MessageEntry{ 201 "BIOSPOSTCode", 202 { 203 "BIOS Power-On Self-Test Code received", 204 "Boot Count: %1; Time Stamp Offset: %2 seconds; POST Code: %3", 205 "OK", 206 3, 207 { 208 "number", 209 "number", 210 "number", 211 }, 212 "None.", 213 }}, 214 MessageEntry{ 215 "BIOSPOSTError", 216 { 217 "Indicates BIOS POST has encountered an error.", 218 "BIOS POST Error. Error Code=%1", 219 "Warning", 220 1, 221 { 222 "number", 223 }, 224 "None.", 225 }}, 226 MessageEntry{ 227 "BIOSRecoveryComplete", 228 { 229 "Indicates BIOS Recovery has completed.", 230 "BIOS Recovery Complete.", 231 "OK", 232 0, 233 {}, 234 "None.", 235 }}, 236 MessageEntry{ 237 "BIOSRecoveryStart", 238 { 239 "Indicates BIOS Recovery has started.", 240 "BIOS Recovery Start.", 241 "Warning", 242 0, 243 {}, 244 "None.", 245 }}, 246 MessageEntry{ 247 "BMCBootReason", 248 { 249 "Indicates the reason why BMC firmware booted.", 250 "BMC firmware version %1 booted due to %2.", 251 "OK", 252 2, 253 { 254 "string", 255 "string", 256 }, 257 "None.", 258 }}, 259 MessageEntry{ 260 "BMCFirmwarePanicReason", 261 { 262 "Indicates the reason for last BMC firmware panic.", 263 "BMC firmware panic occurred due to %1.", 264 "Warning", 265 1, 266 { 267 "string", 268 }, 269 "None.", 270 }}, 271 MessageEntry{ 272 "BMCFirmwareRecoveryReason", 273 { 274 "Indicates the reason for last BMC firmware recovery.", 275 "BMC firmware recovery occurred due to %1.", 276 "Warning", 277 1, 278 { 279 "string", 280 }, 281 "None.", 282 }}, 283 MessageEntry{ 284 "BMCFirmwareResiliencyError", 285 { 286 "Indicates BMC firmware encountered resilience error.", 287 "BMC firmware resiliency error. Error reason: %1.", 288 "Critical", 289 1, 290 { 291 "string", 292 }, 293 "None.", 294 }}, 295 MessageEntry{ 296 "BMCKernelPanic", 297 { 298 "Indicates that BMC kernel panic occurred.", 299 "BMC rebooted due to kernel panic.", 300 "OK", 301 0, 302 {}, 303 "None.", 304 }}, 305 MessageEntry{ 306 "CPLDFirmwarePanicReason", 307 { 308 "Indicates the reason for CPLD firmware panic.", 309 "CPLD firmware panic occurred due to %1.", 310 "Warning", 311 1, 312 { 313 "string", 314 }, 315 "None.", 316 }}, 317 MessageEntry{ 318 "CPLDFirmwareRecoveryReason", 319 { 320 "Indicates the reason for CPLD firmware recovery.", 321 "CPLD firmware recovery occurred due to %1.", 322 "Warning", 323 1, 324 { 325 "string", 326 }, 327 "None.", 328 }}, 329 MessageEntry{ 330 "CPLDFirmwareResiliencyError", 331 { 332 "Indicates CPLD firmware encountered resilience error.", 333 "CPLD firmware resiliency error. Error reason: %1.", 334 "Critical", 335 1, 336 { 337 "string", 338 }, 339 "None.", 340 }}, 341 MessageEntry{ 342 "CPUError", 343 { 344 "Indicates that a CPU Error occurred of the specified type or cause.", 345 "CPU Error Occurred: %1.", 346 "Critical", 347 1, 348 { 349 "string", 350 }, 351 "None.", 352 }}, 353 MessageEntry{ 354 "CPUMismatch", 355 { 356 "Indicates that the specified CPU power/current rating is incompatible with the board.", 357 "CPU %1 Mismatch.", 358 "Critical", 359 1, 360 { 361 "number", 362 }, 363 "Install the supported CPU.", 364 }}, 365 MessageEntry{ 366 "CPUThermalTrip", 367 { 368 "Indicates that the specified CPU thermal trip has been asserted.", 369 "CPU %1 Thermal Trip.", 370 "Critical", 371 1, 372 { 373 "number", 374 }, 375 "None.", 376 }}, 377 MessageEntry{ 378 "ChassisIntrusionDetected", 379 { 380 "Indicates that a physical security event of the chassis intrusion has occurred.", 381 "Chassis Intrusion Detected.", 382 "Warning", 383 0, 384 {}, 385 "None.", 386 }}, 387 MessageEntry{ 388 "ChassisIntrusionReset", 389 { 390 "Indicates that chassis intrusion status has recovered.", 391 "Chassis Intrusion Reset.", 392 "OK", 393 0, 394 {}, 395 "None.", 396 }}, 397 MessageEntry{ 398 "ComponentOverTemperature", 399 { 400 "Indicates that the specified component is over temperature.", 401 "%1 over temperature and being throttled.", 402 "Critical", 403 1, 404 { 405 "string", 406 }, 407 "None.", 408 }}, 409 MessageEntry{ 410 "DCPowerOff", 411 { 412 "Indicates that the system DC power is off.", 413 "Host system DC power is off", 414 "OK", 415 0, 416 {}, 417 "None.", 418 }}, 419 MessageEntry{ 420 "DCPowerOn", 421 { 422 "Indicates that the system DC power is on.", 423 "Host system DC power is on", 424 "OK", 425 0, 426 {}, 427 "None.", 428 }}, 429 MessageEntry{ 430 "DriveError", 431 { 432 "Indicates that a Drive Error occurred of the specified type or cause.", 433 "Drive Error Occurred: %1.", 434 "Warning", 435 1, 436 { 437 "string", 438 }, 439 "None.", 440 }}, 441 MessageEntry{ 442 "EventLogCleared", 443 { 444 "Indicates that the event log has been cleared.", 445 "Event Log Cleared.", 446 "OK", 447 0, 448 {}, 449 "None.", 450 }}, 451 MessageEntry{ 452 "FanInserted", 453 { 454 "Indicates that a system fan has been inserted.", 455 "%1 inserted.", 456 "OK", 457 1, 458 { 459 "string", 460 }, 461 "None.", 462 }}, 463 MessageEntry{ 464 "FanRedundancyLost", 465 { 466 "Indicates that system fan redundancy has been lost.", 467 "Fan redundancy lost.", 468 "Warning", 469 0, 470 {}, 471 "None.", 472 }}, 473 MessageEntry{ 474 "FanRedundancyRegained", 475 { 476 "Indicates that system fan redundancy has been regained.", 477 "Fan redundancy regained.", 478 "OK", 479 0, 480 {}, 481 "None.", 482 }}, 483 MessageEntry{ 484 "FanRemoved", 485 { 486 "Indicates that a system fan has been removed.", 487 "%1 removed.", 488 "OK", 489 1, 490 {}, 491 "None.", 492 }}, 493 MessageEntry{ 494 "FirmwareActivationCompleted", 495 { 496 "Indicates a firmware activation has completed successfully.", 497 "%1 firmware activation completed successfully.", 498 "OK", 499 1, 500 { 501 "string", 502 }, 503 "None.", 504 }}, 505 MessageEntry{ 506 "FirmwareActivationFailed", 507 { 508 "Indicates a firmware activation has failed.", 509 "%1 firmware activation failed: %2.", 510 "Warning", 511 2, 512 { 513 "string", 514 "string", 515 }, 516 "None.", 517 }}, 518 MessageEntry{ 519 "FirmwareActivationStarted", 520 { 521 "Indicates a firmware activation has started.", 522 "%1 firmware activation started.", 523 "OK", 524 1, 525 { 526 "string", 527 }, 528 "None.", 529 }}, 530 MessageEntry{ 531 "FirmwareResiliencyError", 532 { 533 "Indicates firmware encountered resilience error.", 534 "Firmware resiliency error. Error reason: %1.", 535 "Critical", 536 1, 537 { 538 "string", 539 }, 540 "None.", 541 }}, 542 MessageEntry{ 543 "FirmwareUpdateCompleted", 544 { 545 "Indicates a firmware update has completed successfully.", 546 "%1 firmware update to version %2 completed successfully.", 547 "OK", 548 2, 549 { 550 "string", 551 "string", 552 }, 553 "None.", 554 }}, 555 MessageEntry{ 556 "FirmwareUpdateFailed", 557 { 558 "Indicates a firmware update has failed.", 559 "%1 firmware update to version %2 failed: %3.", 560 "Warning", 561 3, 562 { 563 "string", 564 "string", 565 "string", 566 }, 567 "None.", 568 }}, 569 MessageEntry{ 570 "FirmwareUpdateStaged", 571 { 572 "Indicates a firmware update has staged successfully.", 573 "%1 firmware update to version %2 staged successfully.", 574 "OK", 575 2, 576 { 577 "string", 578 "string", 579 }, 580 "None.", 581 }}, 582 MessageEntry{ 583 "FirmwareUpdateStarted", 584 { 585 "Indicates a firmware update has started.", 586 "%1 firmware update to version %2 started.", 587 "OK", 588 2, 589 { 590 "string", 591 "string", 592 }, 593 "None.", 594 }}, 595 MessageEntry{ 596 "GeneralFirmwareSecurityViolation", 597 { 598 "Indicates a general firmware security violation has occurred.", 599 "Firmware security violation: %1.", 600 "Critical", 601 1, 602 { 603 "string", 604 }, 605 "None.", 606 }}, 607 MessageEntry{ 608 "IPMIWatchdog", 609 { 610 "Indicates that there is a host watchdog event.", 611 "Host Watchdog Event: %1", 612 "OK", 613 1, 614 { 615 "string", 616 }, 617 "None.", 618 }}, 619 MessageEntry{ 620 "IntelUPILinkWidthReducedToHalf", 621 { 622 "Indicates Intel UPI link width has reduced to half width.", 623 "Intel UPI link width reduced to half. Node=%1.", 624 "Warning", 625 1, 626 { 627 "number", 628 }, 629 "None.", 630 }}, 631 MessageEntry{ 632 "IntelUPILinkWidthReducedToQuarter", 633 { 634 "Indicates Intel UPI link width has reduced to quarter width.", 635 "Intel UPI link width reduced to quarter. Node=%1.", 636 "Warning", 637 1, 638 { 639 "number", 640 }, 641 "None.", 642 }}, 643 MessageEntry{ 644 "InvalidLoginAttempted", 645 { 646 "Indicates that a login was attempted on the specified interface with an invalid username or password.", 647 "Invalid username or password attempted on %1.", 648 "Warning", 649 1, 650 { 651 "string", 652 }, 653 "None.", 654 }}, 655 MessageEntry{ 656 "InvalidUpload", 657 { 658 "Indicates that the uploaded file was invalid.", 659 "Invalid file uploaded to %1: %2.", 660 "Warning", 661 2, 662 { 663 "string", 664 "string", 665 }, 666 "None.", 667 }}, 668 MessageEntry{ 669 "InventoryAdded", 670 { 671 "Indicates that an inventory item with the specified model, type, and serial number was installed.", 672 "%1 %2 with serial number %3 was installed.", 673 "OK", 674 3, 675 { 676 "string", 677 "string", 678 "string", 679 }, 680 "None.", 681 }}, 682 MessageEntry{ 683 "InventoryRemoved", 684 { 685 "Indicates that an inventory item with the specified model, type, and serial number was removed.", 686 "%1 %2 with serial number %3 was removed.", 687 "OK", 688 3, 689 { 690 "string", 691 "string", 692 "string", 693 }, 694 "None.", 695 }}, 696 MessageEntry{ 697 "LanLost", 698 { 699 "Indicates that a physical security event of the LAN leash has lost.", 700 "%1 LAN leash lost.", 701 "Warning", 702 1, 703 { 704 "string", 705 }, 706 "None.", 707 }}, 708 MessageEntry{ 709 "LanRegained", 710 { 711 "Indicates that LAN link status has reconnected.", 712 "%1 LAN leash regained.", 713 "OK", 714 1, 715 { 716 "string", 717 }, 718 "None.", 719 }}, 720 MessageEntry{ 721 "LegacyPCIPERR", 722 { 723 "Indicates a Legacy PCI PERR.", 724 "Legacy PCI PERR. Bus=%1 Device=%2 Function=%3.", 725 "Warning", 726 3, 727 { 728 "number", 729 "number", 730 "number", 731 }, 732 "None.", 733 }}, 734 MessageEntry{ 735 "LegacyPCISERR", 736 { 737 "Indicates a Legacy PCI SERR.", 738 "Legacy PCI SERR. Bus=%1 Device=%2 Function=%3.", 739 "Critical", 740 3, 741 { 742 "number", 743 "number", 744 "number", 745 }, 746 "None.", 747 }}, 748 MessageEntry{ 749 "MEAutoConfigFailed", 750 { 751 "Indicates that Intel ME power sensor auto-configuration has failed.", 752 "Intel ME power sensor auto-configuration failed. Power monitoring, limiting and HW protection features might be unavailable. Failure reason: %1", 753 "Critical", 754 1, 755 { 756 "string", 757 }, 758 "Ensure that Intel ME configuration for power sources is correct.", 759 }}, 760 MessageEntry{ 761 "MEAutoConfigSuccess", 762 { 763 "Indicates that Intel ME has performed successful power sensor auto-configuration.", 764 "Intel ME power sensor auto-configuration succeeded. Determined sources for domain readings are: DC Power: %1 ; Chassis Power: %2 ; PSU Efficiency: %3 ; Unamanaged power: %4", 765 "OK", 766 4, 767 { 768 "string", 769 "string", 770 "string", 771 "string", 772 }, 773 "None.", 774 }}, 775 MessageEntry{ 776 "MEBootGuardHealthEvent", 777 { 778 "Indicates that Intel ME has detected error during operations of Intel Boot Guard", 779 "Intel ME has detected following issue with Intel Boot Guard: %1", 780 "Critical", 781 1, 782 { 783 "string", 784 }, 785 "None.", 786 }}, 787 MessageEntry{ 788 "MECpuDebugCapabilityDisabled", 789 { 790 "Indicates that Intel ME has detected situation in which CPU Debug Capability is disabled.", 791 "CPU Debug Capability disabled", 792 "Warning", 793 0, 794 {}, 795 "None.", 796 }}, 797 MessageEntry{ 798 "MEDirectFlashUpdateRequested", 799 { 800 "Indicates that BIOS has requested Direct Flash Update (DFU) of Intel ME", 801 "Intel ME Firmware switched to recovery mode to perform full update from BIOS.", 802 "OK", 803 0, 804 {}, 805 "This is transient state. Intel ME Firmware should return to operational mode after successful image update performed by the BIOS.", 806 }}, 807 MessageEntry{ 808 "MEExceptionDuringShutdown", 809 { 810 "Indicates that Intel ME could not successfully perform emergency host shutdown.", 811 "Power Down command triggered by Intel Node Manager policy failure action and Intel ME forced shutdown. BMC probably did not respond correctly to Chassis Control.", 812 "Warning", 813 0, 814 {}, 815 "Verify the Intel Node Manager policy configuration.", 816 }}, 817 MessageEntry{ 818 "MEFactoryResetError", 819 { 820 "Indicates that Intel ME has ben restored to factory preset.", 821 "Intel ME has performed automatic reset to factory presets due to following reason: %1", 822 "Critical", 823 1, 824 { 825 "string", 826 }, 827 "If error is persistent the Flash device must be replaced.", 828 }}, 829 MessageEntry{ 830 "MEFactoryRestore", 831 { 832 "Indicates that Intel ME has ben restored to factory preset.", 833 "Intel ME has performed automatic reset to factory presets due to following reason: %1", 834 "OK", 835 1, 836 { 837 "string", 838 }, 839 "If error is persistent the Flash device must be replaced.", 840 }}, 841 MessageEntry{ 842 "MEFirmwareException", 843 { 844 "Indicates that Intel ME has encountered firmware exception during execution.", 845 "Intel ME has encountered firmware exception. Error code = %1", 846 "Warning", 847 1, 848 { 849 "string", 850 }, 851 "Restore factory presets using Force ME Recovery IPMI command or by doing AC power cycle with Recovery jumper asserted. If this does not clear the issue, reflash the SPI flash. If the issue persists, provide the content of error code to Intel support team for interpretation. (Error codes are not documented because they only provide clues that must be interpreted individually..", 852 }}, 853 MessageEntry{ 854 "MEFirmwarePanicReason", 855 { 856 "Indicates the reason for ME firmware panic.", 857 "ME firmware panic occurred due to %1.", 858 "Warning", 859 1, 860 { 861 "string", 862 }, 863 "None.", 864 }}, 865 MessageEntry{ 866 "MEFirmwareRecoveryReason", 867 { 868 "Indicates the reason for ME firmware recovery.", 869 "ME firmware recovery occurred due to %1.", 870 "Warning", 871 1, 872 { 873 "string", 874 }, 875 "None.", 876 }}, 877 MessageEntry{ 878 "MEFirmwareResiliencyError", 879 { 880 "Indicates ME firmware encountered resilience error.", 881 "ME firmware resiliency error. Error reason: %1.", 882 "Critical", 883 1, 884 { 885 "string", 886 }, 887 "None.", 888 }}, 889 MessageEntry{ 890 "MEFlashEraseError", 891 { 892 "Indicates that Intel ME was unable to finish flash erase procedure.", 893 "Intel ME has encountered an error during Flash erasure procedure probably due to Flash part corruption.", 894 "Critical", 895 0, 896 {}, 897 "The Flash device must be replaced.", 898 }}, 899 MessageEntry{ 900 "MEFlashStateInformation", 901 { 902 "Indicates that Intel ME has encountered a problem during IO to flash device.", 903 "Intel ME has encountered problem during IO to flash device. Reason: %1", 904 "Critical", 905 1, 906 { 907 "string", 908 }, 909 "If flash wear-out protection occurred wait until it expires. Otherwise - flash device must be replaced.", 910 }}, 911 MessageEntry{ 912 "MEFlashStateInformationWritingEnabled", 913 { 914 "Indicates that Intel ME has encountered a problem during IO to flash device.", 915 "Intel ME has encountered problem during IO to flash device. Reason: %1", 916 "OK", 917 1, 918 { 919 "string", 920 }, 921 "If flash wear-out protection occurred wait until it expires. Otherwise - flash device must be replaced.", 922 }}, 923 MessageEntry{ 924 "MEFlashVerificationError", 925 { 926 "Indicates that Intel ME encountered invalid flash descriptor region.", 927 "Intel ME has detected invalid flash descriptor region. Following error is detected: %1", 928 "Critical", 929 1, 930 { 931 "string", 932 }, 933 "Flash Descriptor Region must be created correctly.", 934 }}, 935 MessageEntry{ 936 "MEFlashWearOutWarning", 937 { 938 "Indicates that Intel ME has reached certain threshold of flash write operations.", 939 "Warning threshold for number of flash operations has been exceeded. Current percentage of write operations capacity: %1", 940 "Warning", 941 1, 942 { 943 "number", 944 }, 945 "No immediate repair action needed.", 946 }}, 947 MessageEntry{ 948 "MEImageExecutionFailed", 949 { 950 "Indicates that Intel ME could not load primary FW image.", 951 "Intel ME Recovery Image or backup operational image loaded because operational image is corrupted. This may be either caused by Flash device corruption or failed upgrade procedure.", 952 "Critical", 953 0, 954 {}, 955 "Either the Flash device must be replaced (if error is persistent) or the upgrade procedure must be started again.", 956 }}, 957 MessageEntry{ 958 "MEInternalError", 959 { 960 "Indicates that Intel ME encountered internal error leading to watchdog reset.", 961 "Error during Intel ME execution. Watchdog timeout has expired.", 962 "Critical", 963 0, 964 {}, 965 "Firmware should automatically recover from error state. If error is persistent then operational image shall be updated or hardware board repair is needed.", 966 }}, 967 MessageEntry{ 968 "MEManufacturingError", 969 { 970 "Indicates that Intel ME is unable to start in operational mode due to wrong configuration.", 971 "Wrong manufacturing configuration detected by Intel ME Firmware. Unable to start operational mode. Reason: %1", 972 "Critical", 973 1, 974 { 975 "string", 976 }, 977 " If error is persistent the Flash device must be replaced or FW configuration must be updated. Trace logs might be gathered for detailed information.", 978 }}, 979 MessageEntry{ 980 "MEMctpInterfaceError", 981 { 982 "Indicates that Intel ME has encountered an error in MCTP protocol.", 983 "Intel ME has detected MCTP interface failure and it is not functional any more. It may indicate the situation when MCTP was not configured by BIOS or a defect which may need a Host reset to recover from. Details: %1", 984 "Critical", 985 1, 986 { 987 "string", 988 }, 989 "Recovery via CPU Host reset or platform reset. If error is persistent, deep-dive platform-level debugging is required.", 990 }}, 991 MessageEntry{ 992 "MEMultiPchModeMisconfig", 993 { 994 "Indicates that Intel ME has encountered problems in initializing Multi-PCH mode.", 995 "Intel ME error in Multi-PCH mode: %1", 996 "Critical", 997 1, 998 { 999 "string", 1000 }, 1001 "None.", 1002 }}, 1003 MessageEntry{ 1004 "MEPeciOverDmiError", 1005 { 1006 "Indicates that Intel ME is unable to communicate using PECI over DMI.", 1007 "Intel ME has detected PECI over DMI interface failure and it is not functional any more. It may indicate the situation when PECI over DMI was not configured by BIOS or a defect which may require a CPU Host reset to recover from. Details: %1", 1008 "Critical", 1009 1, 1010 { 1011 "string", 1012 }, 1013 "Recovery via CPU Host reset or platform reset. If error is persistent, deep-dive platform-level debugging is required.", 1014 }}, 1015 MessageEntry{ 1016 "MEPttHealthEvent", 1017 { 1018 "Indicates that Intel ME has encountered issue with Intel PTT", 1019 "Intel ME has detected following issue with Intel PTT: %1", 1020 "Warning", 1021 1, 1022 { 1023 "string", 1024 }, 1025 "None.", 1026 }}, 1027 MessageEntry{ 1028 "MERecoveryGpioForced", 1029 { 1030 "Indicates that Intel ME image is booted in recovery mode due to GPIO assertion.", 1031 "Intel ME Recovery Image loaded due to recovery MGPIO pin asserted. Pin number is configurable in factory presets, Default recovery pin is MGPIO1.", 1032 "OK", 1033 0, 1034 {}, 1035 "Deassert recovery GPIO and reset the Intel ME back to operational mode. If Recovery Jumper is in legacy behavior, a ME reset (eg. Cold Reset IPMI cmd) is needed to have ME back in operational mode.", 1036 }}, 1037 MessageEntry{ 1038 "MERestrictedMode", 1039 { 1040 "Indicates events related to Intel ME restricted mode.", 1041 "Intel ME restricted mode information: %1", 1042 "Critical", 1043 1, 1044 { 1045 "string", 1046 }, 1047 "None.", 1048 }}, 1049 MessageEntry{ 1050 "MESmbusLinkFailure", 1051 { 1052 "Indicate that Intel ME encountered SMBus link error.", 1053 "Intel ME has detected SMBus link error. Sensor Bus: %1 , MUX Address: %2 ", 1054 "Critical", 1055 2, 1056 { 1057 "string", 1058 "string", 1059 }, 1060 "Devices connected to given SMLINK might cause communication corruption. See error code and refer to Intel ME External Interfaces Specification for details.", 1061 }}, 1062 MessageEntry{ 1063 "MEUmaError", 1064 { 1065 "Indicates that Intel ME has encountered UMA operation error.", 1066 "Intel ME has encountered UMA operation error. Details: %1", 1067 "Critical", 1068 1, 1069 { 1070 "string", 1071 }, 1072 "Platform reset when UMA not configured correctly, or when error occurred during normal operation on correctly configured UMA multiple times leading to Intel ME entering Recovery or restricted operational mode.", 1073 }}, 1074 MessageEntry{ 1075 "MEUnsupportedFeature", 1076 { 1077 "Indicates that Intel ME is configuration with feature which is not supported on this platform.", 1078 "Feature not supported in current segment detected by Intel ME Firmware. Details: %1", 1079 "Critical", 1080 1, 1081 { 1082 "string", 1083 }, 1084 "Proper FW configuration must be updated or use the Flash device with proper FW configuration", 1085 }}, 1086 MessageEntry{ 1087 "ManufacturingModeEntered", 1088 { 1089 "Indicates that the BMC entered Factory, or Manufacturing mode.", 1090 "Entered Manufacturing Mode.", 1091 "Critical", 1092 0, 1093 {}, 1094 "None.", 1095 }}, 1096 MessageEntry{ 1097 "ManufacturingModeExited", 1098 { 1099 "Indicates that the BMC exited Factory, or Manufacturing mode.", 1100 "Exited Manufacturing Mode.", 1101 "OK", 1102 0, 1103 {}, 1104 "None.", 1105 }}, 1106 MessageEntry{ 1107 "MemoryECCCorrectable", 1108 { 1109 "Indicates a Correctable Memory ECC error.", 1110 "Memory ECC correctable error. Socket=%1 Channel=%2 DIMM=%3 Rank=%4.", 1111 "Warning", 1112 4, 1113 { 1114 "number", 1115 "string", 1116 "number", 1117 "number", 1118 }, 1119 "None.", 1120 }}, 1121 MessageEntry{ 1122 "MemoryECCUncorrectable", 1123 { 1124 "Indicates an Uncorrectable Memory ECC error.", 1125 "Memory ECC uncorrectable error. Socket=%1 Channel=%2 DIMM=%3 Rank=%4.", 1126 "Critical", 1127 4, 1128 { 1129 "number", 1130 "string", 1131 "number", 1132 "number", 1133 }, 1134 "None.", 1135 }}, 1136 MessageEntry{ 1137 "MemoryParityCommandAndAddress", 1138 { 1139 "Indicates a Command and Address parity error.", 1140 "Command and Address parity error. Socket=%1 Channel=%2 DIMM=%3 ChannelValid=%4 DIMMValid=%5.", 1141 "Critical", 1142 5, 1143 { 1144 "number", 1145 "string", 1146 "number", 1147 "number", 1148 "number", 1149 }, 1150 "None.", 1151 }}, 1152 MessageEntry{ 1153 "MemoryParityNotKnown", 1154 { 1155 "Indicates an unknown parity error.", 1156 "Memory parity error. Socket=%1 Channel=%2 DIMM=%3 ChannelValid=%4 DIMMValid=%5.", 1157 "Critical", 1158 5, 1159 { 1160 "number", 1161 "string", 1162 "number", 1163 "number", 1164 "number", 1165 }, 1166 "None.", 1167 }}, 1168 MessageEntry{ 1169 "MemoryRASConfigurationDisabled", 1170 { 1171 "Indicates Memory RAS Disabled Configuration Status.", 1172 "Memory RAS Configuration Disabled. Error=%1 Mode=%2.", 1173 "OK", 1174 2, 1175 { 1176 "string", 1177 "string", 1178 }, 1179 "None.", 1180 }}, 1181 MessageEntry{ 1182 "MemoryRASConfigurationEnabled", 1183 { 1184 "Indicates Memory RAS Enabled Configuration Status.", 1185 "Memory RAS Configuration Enabled. Error=%1 Mode=%2.", 1186 "OK", 1187 2, 1188 { 1189 "string", 1190 "string", 1191 }, 1192 "None.", 1193 }}, 1194 MessageEntry{ 1195 "MemoryRASModeDisabled", 1196 { 1197 "Indicates Memory RAS Disabled Mode Selection.", 1198 "Memory RAS Mode Select Disabled. Prior Mode=%1 Selected Mode=%2.", 1199 "OK", 1200 2, 1201 { 1202 "string", 1203 "string", 1204 }, 1205 "None.", 1206 }}, 1207 MessageEntry{ 1208 "MemoryRASModeEnabled", 1209 { 1210 "Indicates Memory RAS Enabled Mode Selection.", 1211 "Memory RAS Mode Select Enabled. Prior Mode=%1 Selected Mode=%2.", 1212 "OK", 1213 2, 1214 { 1215 "string", 1216 "string", 1217 }, 1218 "None.", 1219 }}, 1220 MessageEntry{ 1221 "MemoryThermTrip", 1222 { 1223 "Indicates that the system memory ThermTrip is asserted by the specified component.", 1224 "Memory ThermTrip asserted: %1.", 1225 "Critical", 1226 1, 1227 { 1228 "string", 1229 }, 1230 "None.", 1231 }}, 1232 MessageEntry{ 1233 "MirroringRedundancyDegraded", 1234 { 1235 "Indicates the mirroring redundancy state is degraded.", 1236 "Mirroring redundancy state degraded. Socket=%1 Channel=%2 DIMM=%3 Pair=%4 Rank=%5.", 1237 "Warning", 1238 5, 1239 { 1240 "number", 1241 "string", 1242 "number", 1243 "number", 1244 "number", 1245 }, 1246 "None.", 1247 }}, 1248 MessageEntry{ 1249 "MirroringRedundancyFull", 1250 { 1251 "Indicates the mirroring redundancy state is fully redundant.", 1252 "Mirroring redundancy state fully redundant. Socket=%1 Channel=%2 DIMM=%3 Pair=%4 Rank=%5.", 1253 "OK", 1254 5, 1255 { 1256 "number", 1257 "string", 1258 "number", 1259 "number", 1260 "number", 1261 }, 1262 "None.", 1263 }}, 1264 MessageEntry{ 1265 "NMIButtonPressed", 1266 { 1267 "Indicates that the NMI button was pressed.", 1268 "NMI Button Pressed.", 1269 "Critical", 1270 0, 1271 {}, 1272 "None.", 1273 }}, 1274 MessageEntry{ 1275 "NMIDiagnosticInterrupt", 1276 { 1277 "Indicates that an NMI Diagnostic Interrupt has been generated.", 1278 "NMI Diagnostic Interrupt.", 1279 "Critical", 1280 0, 1281 {}, 1282 "None.", 1283 }}, 1284 MessageEntry{ 1285 "PCIeCorrectableAdvisoryNonFatal", 1286 { 1287 "Indicates a PCIe Correctable Advisory Non-fatal Error.", 1288 "PCIe Correctable Advisory Non-fatal Error. Bus=%1 Device=%2 Function=%3.", 1289 "Warning", 1290 3, 1291 { 1292 "number", 1293 "number", 1294 "number", 1295 }, 1296 "None.", 1297 }}, 1298 MessageEntry{ 1299 "PCIeCorrectableBadDLLP", 1300 { 1301 "Indicates a PCIe Correctable Bad DLLP Error.", 1302 "PCIe Correctable Bad DLLP. Bus=%1 Device=%2 Function=%3.", 1303 "Warning", 1304 3, 1305 { 1306 "number", 1307 "number", 1308 "number", 1309 }, 1310 "None.", 1311 }}, 1312 MessageEntry{ 1313 "PCIeCorrectableBadTLP", 1314 { 1315 "Indicates a PCIe Correctable Bad TLP Error.", 1316 "PCIe Correctable Bad TLP. Bus=%1 Device=%2 Function=%3.", 1317 "Warning", 1318 3, 1319 { 1320 "number", 1321 "number", 1322 "number", 1323 }, 1324 "None.", 1325 }}, 1326 MessageEntry{ 1327 "PCIeCorrectableHeaderLogOverflow", 1328 { 1329 "Indicates a PCIe Correctable Header Log Overflow Error.", 1330 "PCIe Correctable Header Log Overflow. Bus=%1 Device=%2 Function=%3.", 1331 "Warning", 1332 3, 1333 { 1334 "number", 1335 "number", 1336 "number", 1337 }, 1338 "None.", 1339 }}, 1340 MessageEntry{ 1341 "PCIeCorrectableInternal", 1342 { 1343 "Indicates a PCIe Correctable Internal Error.", 1344 "PCIe Correctable Internal Error. Bus=%1 Device=%2 Function=%3.", 1345 "Warning", 1346 3, 1347 { 1348 "number", 1349 "number", 1350 "number", 1351 }, 1352 "None.", 1353 }}, 1354 MessageEntry{ 1355 "PCIeCorrectableLinkBWChanged", 1356 { 1357 "Indicates a PCIe Correctable Link BW Changed Error.", 1358 "PCIe Correctable Link BW Changed. Bus=%1 Device=%2 Function=%3.", 1359 "Warning", 1360 3, 1361 { 1362 "number", 1363 "number", 1364 "number", 1365 }, 1366 "None.", 1367 }}, 1368 MessageEntry{ 1369 "PCIeCorrectableReceiverError", 1370 { 1371 "Indicates a PCIe Correctable Receiver Error.", 1372 "PCIe Correctable Receiver Error. Bus=%1 Device=%2 Function=%3.", 1373 "Warning", 1374 3, 1375 { 1376 "number", 1377 "number", 1378 "number", 1379 }, 1380 "None.", 1381 }}, 1382 MessageEntry{ 1383 "PCIeCorrectableReplayNumRollover", 1384 { 1385 "Indicates a PCIe Correctable Replay Num Rollover.", 1386 "PCIe Correctable Replay Num Rollover. Bus=%1 Device=%2 Function=%3.", 1387 "Warning", 1388 3, 1389 { 1390 "number", 1391 "number", 1392 "number", 1393 }, 1394 "None.", 1395 }}, 1396 MessageEntry{ 1397 "PCIeCorrectableReplayTimerTimeout", 1398 { 1399 "Indicates a PCIe Correctable Replay Timer Timeout.", 1400 "PCIe Correctable Replay Timer Timeout. Bus=%1 Device=%2 Function=%3.", 1401 "Warning", 1402 3, 1403 { 1404 "number", 1405 "number", 1406 "number", 1407 }, 1408 "None.", 1409 }}, 1410 MessageEntry{ 1411 "PCIeCorrectableUnspecifiedAERError", 1412 { 1413 "Indicates a PCIe Correctable Unspecified AER Error.", 1414 "PCIe Correctable Unspecified AER Error. Bus=%1 Device=%2 Function=%3.", 1415 "Warning", 1416 3, 1417 { 1418 "number", 1419 "number", 1420 "number", 1421 }, 1422 "None.", 1423 }}, 1424 MessageEntry{ 1425 "PCIeFatalACSViolation", 1426 { 1427 "Indicates a PCIe ACS Violation Error.", 1428 "PCIe Fatal ACS Violation. Bus=%1 Device=%2 Function=%3.", 1429 "Critical", 1430 3, 1431 { 1432 "number", 1433 "number", 1434 "number", 1435 }, 1436 "None.", 1437 }}, 1438 MessageEntry{ 1439 "PCIeFatalAtomicEgressBlocked", 1440 { 1441 "Indicates a PCIe Atomic Egress Blocked Error.", 1442 "PCIe Fatal Atomic Egress Blocked. Bus=%1 Device=%2 Function=%3.", 1443 "Critical", 1444 3, 1445 { 1446 "number", 1447 "number", 1448 "number", 1449 }, 1450 "None.", 1451 }}, 1452 MessageEntry{ 1453 "PCIeFatalCompleterAbort", 1454 { 1455 "Indicates a PCIe Completer Abort Error.", 1456 "PCIe Fatal Completer Abort. Bus=%1 Device=%2 Function=%3.", 1457 "Critical", 1458 3, 1459 { 1460 "number", 1461 "number", 1462 "number", 1463 }, 1464 "None.", 1465 }}, 1466 MessageEntry{ 1467 "PCIeFatalCompletionTimeout", 1468 { 1469 "Indicates a PCIe Completion Timeout Error.", 1470 "PCIe Fatal Completion Timeout. Bus=%1 Device=%2 Function=%3.", 1471 "Critical", 1472 3, 1473 { 1474 "number", 1475 "number", 1476 "number", 1477 }, 1478 "None.", 1479 }}, 1480 MessageEntry{ 1481 "PCIeFatalDataLinkLayerProtocol", 1482 { 1483 "Indicates a PCIe Data Link Layer Protocol Error.", 1484 "PCIe Fatal Data Link Layer Protocol Error. Bus=%1 Device=%2 Function=%3.", 1485 "Critical", 1486 3, 1487 { 1488 "number", 1489 "number", 1490 "number", 1491 }, 1492 "None.", 1493 }}, 1494 MessageEntry{ 1495 "PCIeFatalECRCError", 1496 { 1497 "Indicates a PCIe ECRC Error.", 1498 "PCIe Fatal ECRC Error. Bus=%1 Device=%2 Function=%3.", 1499 "Critical", 1500 3, 1501 { 1502 "number", 1503 "number", 1504 "number", 1505 }, 1506 "None.", 1507 }}, 1508 MessageEntry{ 1509 "PCIeFatalFlowControlProtocol", 1510 { 1511 "Indicates a PCIe Flow Control Protocol Error.", 1512 "PCIe Fatal Flow Control Protocol Error. Bus=%1 Device=%2 Function=%3.", 1513 "Critical", 1514 3, 1515 { 1516 "number", 1517 "number", 1518 "number", 1519 }, 1520 "None.", 1521 }}, 1522 MessageEntry{ 1523 "PCIeFatalMCBlockedTLP", 1524 { 1525 "Indicates a PCIe MC Blocked TLP Error.", 1526 "PCIe Fatal MC Blocked TLP Error. Bus=%1 Device=%2 Function=%3.", 1527 "Critical", 1528 3, 1529 { 1530 "number", 1531 "number", 1532 "number", 1533 }, 1534 "None.", 1535 }}, 1536 MessageEntry{ 1537 "PCIeFatalMalformedTLP", 1538 { 1539 "Indicates a PCIe Malformed TLP Error.", 1540 "PCIe Fatal Malformed TLP Error. Bus=%1 Device=%2 Function=%3.", 1541 "Critical", 1542 3, 1543 { 1544 "number", 1545 "number", 1546 "number", 1547 }, 1548 "None.", 1549 }}, 1550 MessageEntry{ 1551 "PCIeFatalPoisonedTLP", 1552 { 1553 "Indicates a PCIe Poisoned TLP Error.", 1554 "PCIe Fatal Poisoned TLP Error. Bus=%1 Device=%2 Function=%3.", 1555 "Critical", 1556 3, 1557 { 1558 "number", 1559 "number", 1560 "number", 1561 }, 1562 "None.", 1563 }}, 1564 MessageEntry{ 1565 "PCIeFatalReceivedErrNonFatalMessage", 1566 { 1567 "Indicates a PCIe Received ERR_NONFATAL Message Error.", 1568 "PCIe Fatal Received ERR_NONFATAL Message. Bus=%1 Device=%2 Function=%3.", 1569 "Critical", 1570 3, 1571 { 1572 "number", 1573 "number", 1574 "number", 1575 }, 1576 "None.", 1577 }}, 1578 MessageEntry{ 1579 "PCIeFatalReceivedFatalMessageFromDownstream", 1580 { 1581 "Indicates a PCIe Received Fatal Message From Downstream Error.", 1582 "PCIe Fatal Received Fatal Message From Downstream. Bus=%1 Device=%2 Function=%3.", 1583 "Critical", 1584 3, 1585 { 1586 "number", 1587 "number", 1588 "number", 1589 }, 1590 "None.", 1591 }}, 1592 MessageEntry{ 1593 "PCIeFatalReceiverBufferOverflow", 1594 { 1595 "Indicates a PCIe Receiver Buffer Overflow Error.", 1596 "PCIe Fatal Receiver Buffer Overflow. Bus=%1 Device=%2 Function=%3.", 1597 "Critical", 1598 3, 1599 { 1600 "number", 1601 "number", 1602 "number", 1603 }, 1604 "None.", 1605 }}, 1606 MessageEntry{ 1607 "PCIeFatalSurpriseLinkDown", 1608 { 1609 "Indicates a PCIe Surprise Link Down Error.", 1610 "PCIe Fatal Surprise Link Down Error. Bus=%1 Device=%2 Function=%3.", 1611 "Critical", 1612 3, 1613 { 1614 "number", 1615 "number", 1616 "number", 1617 }, 1618 "None.", 1619 }}, 1620 MessageEntry{ 1621 "PCIeFatalTLPPrefixBlocked", 1622 { 1623 "Indicates a PCIe TLP Prefix Blocked Error.", 1624 "PCIe Fatal TLP Prefix Blocked Error. Bus=%1 Device=%2 Function=%3.", 1625 "Critical", 1626 3, 1627 { 1628 "number", 1629 "number", 1630 "number", 1631 }, 1632 "None.", 1633 }}, 1634 MessageEntry{ 1635 "PCIeFatalUncorrectableInternal", 1636 { 1637 "Indicates a PCIe Uncorrectable Internal Error.", 1638 "PCIe Fatal Uncorrectable Internal Error. Bus=%1 Device=%2 Function=%3.", 1639 "Critical", 1640 3, 1641 { 1642 "number", 1643 "number", 1644 "number", 1645 }, 1646 "None.", 1647 }}, 1648 MessageEntry{ 1649 "PCIeFatalUnexpectedCompletion", 1650 { 1651 "Indicates a PCIe Unexpected Completion Error.", 1652 "PCIe Fatal Unexpected Completion. Bus=%1 Device=%2 Function=%3.", 1653 "Critical", 1654 3, 1655 { 1656 "number", 1657 "number", 1658 "number", 1659 }, 1660 "None.", 1661 }}, 1662 MessageEntry{ 1663 "PCIeFatalUnspecifiedNonAERFatalError", 1664 { 1665 "Indicates a PCIe Unspecified Non-AER Fatal Error.", 1666 "PCIe Fatal Unspecified Non-AER Fatal Error. Bus=%1 Device=%2 Function=%3.", 1667 "Critical", 1668 3, 1669 { 1670 "number", 1671 "number", 1672 "number", 1673 }, 1674 "None.", 1675 }}, 1676 MessageEntry{ 1677 "PCIeFatalUnsupportedRequest", 1678 { 1679 "Indicates a PCIe Unsupported Request Error.", 1680 "PCIe Fatal Unsupported Request. Bus=%1 Device=%2 Function=%3.", 1681 "Critical", 1682 3, 1683 { 1684 "number", 1685 "number", 1686 "number", 1687 }, 1688 "None.", 1689 }}, 1690 MessageEntry{ 1691 "PowerButtonLongPressed", 1692 { 1693 "Indicates that the power button was long pressed.", 1694 "Power Button Long Pressed.", 1695 "OK", 1696 0, 1697 {}, 1698 "None.", 1699 }}, 1700 MessageEntry{ 1701 "PowerButtonPressed", 1702 { 1703 "Indicates that the power button was pressed.", 1704 "Power Button Pressed.", 1705 "OK", 1706 0, 1707 {}, 1708 "None.", 1709 }}, 1710 MessageEntry{ 1711 "PowerRestorePolicyApplied", 1712 { 1713 "Indicates that power was restored and the BMC has applied the restore policy.", 1714 "Power restore policy applied.", 1715 "OK", 1716 0, 1717 {}, 1718 "None.", 1719 }}, 1720 MessageEntry{ 1721 "PowerSupplyConfigurationError", 1722 { 1723 "Indicates an error in power supply configuration.", 1724 "Power supply %1 configuration error.", 1725 "Warning", 1726 1, 1727 { 1728 "string", 1729 }, 1730 "None.", 1731 }}, 1732 MessageEntry{ 1733 "PowerSupplyConfigurationErrorRecovered", 1734 { 1735 "Indicates that power supply configuration error recovered from a failure.", 1736 "Power supply %1 configuration error recovered.", 1737 "OK", 1738 1, 1739 { 1740 "string", 1741 }, 1742 "None.", 1743 }}, 1744 MessageEntry{ 1745 "PowerSupplyFailed", 1746 { 1747 "Indicates that a power supply has failed.", 1748 "Power supply %1 failed.", 1749 "Warning", 1750 1, 1751 { 1752 "string", 1753 }, 1754 "None.", 1755 }}, 1756 MessageEntry{ 1757 "PowerSupplyFailurePredicted", 1758 { 1759 "Indicates that a power supply is predicted to fail.", 1760 "Power supply %1 failure predicted.", 1761 "Warning", 1762 1, 1763 { 1764 "string", 1765 }, 1766 "None.", 1767 }}, 1768 MessageEntry{ 1769 "PowerSupplyFanFailed", 1770 { 1771 "Indicates that the specified power supply fan has failed.", 1772 "Power supply %1 fan %2 failed.", 1773 "Warning", 1774 2, 1775 { 1776 "string", 1777 "string", 1778 }, 1779 "None.", 1780 }}, 1781 MessageEntry{ 1782 "PowerSupplyFanRecovered", 1783 { 1784 "Indicates that the power supply fan recovered from a failure.", 1785 "Power supply %1 fan %2 recovered.", 1786 "OK", 1787 2, 1788 { 1789 "string", 1790 "string", 1791 }, 1792 "None.", 1793 }}, 1794 MessageEntry{ 1795 "PowerSupplyInserted", 1796 { 1797 "Indicates that a power supply has been inserted.", 1798 "Power supply %1 inserted.", 1799 "OK", 1800 1, 1801 { 1802 "string", 1803 }, 1804 "None.", 1805 }}, 1806 MessageEntry{ 1807 "PowerSupplyPowerGoodFailed", 1808 { 1809 "Indicates that the power supply power good signal failed to assert within the specified time.", 1810 "Power supply power good failed to assert within %1 milliseconds.", 1811 "Critical", 1812 1, 1813 { 1814 "number", 1815 }, 1816 "None.", 1817 }}, 1818 MessageEntry{ 1819 "PowerSupplyPowerLost", 1820 { 1821 "Indicates that a power supply has lost input power.", 1822 "Power supply %1 power lost.", 1823 "Warning", 1824 1, 1825 { 1826 "string", 1827 }, 1828 "None.", 1829 }}, 1830 MessageEntry{ 1831 "PowerSupplyPowerRestored", 1832 { 1833 "Indicates that a power supply input power was restored.", 1834 "Power supply %1 power restored.", 1835 "OK", 1836 1, 1837 { 1838 "string", 1839 }, 1840 "None.", 1841 }}, 1842 MessageEntry{ 1843 "PowerSupplyPredictedFailureRecovered", 1844 { 1845 "Indicates that a power supply recovered from a predicted failure.", 1846 "Power supply %1 predicted failure recovered.", 1847 "OK", 1848 1, 1849 { 1850 "string", 1851 }, 1852 "None.", 1853 }}, 1854 MessageEntry{ 1855 "PowerSupplyRecovered", 1856 { 1857 "Indicates that a power supply recovered from a failure.", 1858 "Power supply %1 recovered.", 1859 "OK", 1860 1, 1861 { 1862 "string", 1863 }, 1864 "None.", 1865 }}, 1866 MessageEntry{ 1867 "PowerSupplyRemoved", 1868 { 1869 "Indicates that a power supply has been removed.", 1870 "Power supply %1 removed.", 1871 "Warning", 1872 1, 1873 { 1874 "string", 1875 }, 1876 "None.", 1877 }}, 1878 MessageEntry{ 1879 "PowerUnitDegradedFromNonRedundant", 1880 { 1881 "Indicates that power unit is come back to redundant fromnonredundant but is still not in full redundancy mode.", 1882 "Power Unit degraded from nonredundant.", 1883 "Warning", 1884 0, 1885 {}, 1886 "None.", 1887 }}, 1888 MessageEntry{ 1889 "PowerUnitDegradedFromRedundant", 1890 { 1891 "Indicates that power unit is degarded from full redundancy mode.", 1892 "Power Unit degraded from redundant.", 1893 "Warning", 1894 0, 1895 {}, 1896 "None.", 1897 }}, 1898 MessageEntry{ 1899 "PowerUnitNonRedundantFromInsufficient", 1900 { 1901 "Indicates that power unit is not in redundancy mode and getsufficient power to support redundancy from insufficientpower.", 1902 "Power Unit NonRedundant from insufficient to sufficient.", 1903 "Warning", 1904 0, 1905 {}, 1906 "None.", 1907 }}, 1908 MessageEntry{ 1909 "PowerUnitNonRedundantInsufficient", 1910 { 1911 "Indicates that power unit do not have sufficient power to support redundancy.", 1912 "Power Unit NonRedundant and has insufficient resource.", 1913 "Critical", 1914 0, 1915 {}, 1916 "None.", 1917 }}, 1918 MessageEntry{ 1919 "PowerUnitNonRedundantSufficient", 1920 { 1921 "Indicates that power unit is not in redundancy mode but stillhas sufficient power to support redundancy.", 1922 "Power Unit Nonredundant but has sufficient resource.", 1923 "Warning", 1924 0, 1925 {}, 1926 "None.", 1927 }}, 1928 MessageEntry{ 1929 "PowerUnitRedundancyDegraded", 1930 { 1931 "Indicates that power unit redundancy has been degraded.", 1932 "Power Unit Redundancy degraded.", 1933 "Warning", 1934 0, 1935 {}, 1936 "None.", 1937 }}, 1938 MessageEntry{ 1939 "PowerUnitRedundancyLost", 1940 { 1941 "Indicates that power unit redundancy has been lost.", 1942 "Power Unit Redundancy lost.", 1943 "Warning", 1944 0, 1945 {}, 1946 "None.", 1947 }}, 1948 MessageEntry{ 1949 "PowerUnitRedundancyRegained", 1950 { 1951 "Indicates that power unit full redundancy has been regained.", 1952 "Power Unit Redundancy regained.", 1953 "OK", 1954 0, 1955 {}, 1956 "None.", 1957 }}, 1958 MessageEntry{ 1959 "ResetButtonPressed", 1960 { 1961 "Indicates that the reset button was pressed.", 1962 "Reset Button Pressed.", 1963 "OK", 1964 0, 1965 {}, 1966 "None.", 1967 }}, 1968 MessageEntry{ 1969 "SELEntryAdded", 1970 { 1971 "Indicates a SEL entry was added using the Add SEL Entry or Platform Event command.", 1972 "SEL Entry Added: %1", 1973 "OK", 1974 1, 1975 { 1976 "string", 1977 }, 1978 "None.", 1979 }}, 1980 MessageEntry{ 1981 "SecurityBoot2ndFlashEnabled", 1982 { 1983 "Indicates that the BMC 2nd boot flash is enabled.", 1984 "BMC 2nd boot flash is enabled.", 1985 "Critical", 1986 0, 1987 {}, 1988 "None.", 1989 }}, 1990 MessageEntry{ 1991 "SecurityP2aBridgeEnabled", 1992 { 1993 "Indicates that the P2A bridge is enabled.", 1994 "P2A(PCIe to AHB) bridge is enabled.", 1995 "Critical", 1996 0, 1997 {}, 1998 "None.", 1999 }}, 2000 MessageEntry{ 2001 "SecurityUartPortDebugEnabled", 2002 { 2003 "Indicates that the uart port debug is enabled.", 2004 "Uart port debug is enabled.", 2005 "Critical", 2006 0, 2007 {}, 2008 "None.", 2009 }}, 2010 MessageEntry{ 2011 "SecurityUserNonRootUidZeroAssigned", 2012 { 2013 "Indicates that non root user assigned with user ID zero.", 2014 "User ID Zero is assigned with non-root user.", 2015 "Critical", 2016 0, 2017 {}, 2018 "None.", 2019 }}, 2020 MessageEntry{ 2021 "SecurityUserNonRootUidZeroRemoved", 2022 { 2023 "Indicates that non root user ID is removed", 2024 "Non root user assigned with user ID zero is removed.", 2025 "OK", 2026 0, 2027 {}, 2028 "None.", 2029 }}, 2030 MessageEntry{ 2031 "SecurityUserRootDisabled", 2032 { 2033 "Indicates that system root user is disabled.", 2034 "User root is disabled.", 2035 "OK", 2036 0, 2037 {}, 2038 "None.", 2039 }}, 2040 MessageEntry{ 2041 "SecurityUserRootEnabled", 2042 { 2043 "Indicates that system root user is enabled.", 2044 "User root is enabled.", 2045 "Critical", 2046 0, 2047 {}, 2048 "None.", 2049 }}, 2050 MessageEntry{ 2051 "SecurityUserStrongHashAlgoRestored", 2052 { 2053 "Indicates that password computing hash algorithm changed.", 2054 "Password computing hash algorithm is changed to sha256/sha512.", 2055 "OK", 2056 0, 2057 {}, 2058 "None.", 2059 }}, 2060 MessageEntry{ 2061 "SecurityUserUnsupportedShellEnabled", 2062 { 2063 "Indicates that unsupported shell is enabled.", 2064 "Unsupported shell is enabled.", 2065 "Critical", 2066 0, 2067 {}, 2068 "None.", 2069 }}, 2070 MessageEntry{ 2071 "SecurityUserUnsupportedShellRemoved", 2072 { 2073 "Indicates that unsupported shell is removed.", 2074 "Unsupported shell is removed.", 2075 "OK", 2076 0, 2077 {}, 2078 "None.", 2079 }}, 2080 MessageEntry{ 2081 "SecurityUserWeakHashAlgoEnabled", 2082 { 2083 "Indicates that weak password computing hash algorithm is enabled.", 2084 "Weak password computing hash algorithm is enabled.", 2085 "Critical", 2086 0, 2087 {}, 2088 "None.", 2089 }}, 2090 MessageEntry{ 2091 "SensorThresholdCriticalHighGoingHigh", 2092 { 2093 "Indicates that a threshold sensor has crossed a critical high threshold going high.", 2094 "%1 sensor crossed a critical high threshold going high. Reading=%2 Threshold=%3.", 2095 "Critical", 2096 3, 2097 { 2098 "string", 2099 "number", 2100 "number", 2101 }, 2102 "Check the sensor or subsystem for errors.", 2103 }}, 2104 MessageEntry{ 2105 "SensorThresholdCriticalHighGoingLow", 2106 { 2107 "Indicates that a threshold sensor has crossed a critical high threshold going low.", 2108 "%1 sensor crossed a critical high threshold going low. Reading=%2 Threshold=%3.", 2109 "OK", 2110 3, 2111 { 2112 "string", 2113 "number", 2114 "number", 2115 }, 2116 "None.", 2117 }}, 2118 MessageEntry{ 2119 "SensorThresholdCriticalLowGoingHigh", 2120 { 2121 "Indicates that a threshold sensor has crossed a critical low threshold going high.", 2122 "%1 sensor crossed a critical low threshold going high. Reading=%2 Threshold=%3.", 2123 "OK", 2124 3, 2125 { 2126 "string", 2127 "number", 2128 "number", 2129 }, 2130 "None.", 2131 }}, 2132 MessageEntry{ 2133 "SensorThresholdCriticalLowGoingLow", 2134 { 2135 "Indicates that a threshold sensor has crossed a critical low threshold going low.", 2136 "%1 sensor crossed a critical low threshold going low. Reading=%2 Threshold=%3.", 2137 "Critical", 2138 3, 2139 { 2140 "string", 2141 "number", 2142 "number", 2143 }, 2144 "Check the sensor or subsystem for errors.", 2145 }}, 2146 MessageEntry{ 2147 "SensorThresholdWarningHighGoingHigh", 2148 { 2149 "Indicates that a threshold sensor has crossed a warning high threshold going high.", 2150 "%1 sensor crossed a warning high threshold going high. Reading=%2 Threshold=%3.", 2151 "Warning", 2152 3, 2153 { 2154 "string", 2155 "number", 2156 "number", 2157 }, 2158 "Check the sensor or subsystem for errors.", 2159 }}, 2160 MessageEntry{ 2161 "SensorThresholdWarningHighGoingLow", 2162 { 2163 "Indicates that a threshold sensor has crossed a warning high threshold going low.", 2164 "%1 sensor crossed a warning high threshold going low. Reading=%2 Threshold=%3.", 2165 "OK", 2166 3, 2167 { 2168 "string", 2169 "number", 2170 "number", 2171 }, 2172 "None.", 2173 }}, 2174 MessageEntry{ 2175 "SensorThresholdWarningLowGoingHigh", 2176 { 2177 "Indicates that a threshold sensor has crossed a warning low threshold going high.", 2178 "%1 sensor crossed a warning low threshold going high. Reading=%2 Threshold=%3.", 2179 "OK", 2180 3, 2181 { 2182 "string", 2183 "number", 2184 "number", 2185 }, 2186 "None.", 2187 }}, 2188 MessageEntry{ 2189 "SensorThresholdWarningLowGoingLow", 2190 { 2191 "Indicates that a threshold sensor has crossed a warning low threshold going low.", 2192 "%1 sensor crossed a warning low threshold going low. Reading=%2 Threshold=%3.", 2193 "Warning", 2194 3, 2195 { 2196 "string", 2197 "number", 2198 "number", 2199 }, 2200 "Check the sensor or subsystem for errors.", 2201 }}, 2202 MessageEntry{ 2203 "ServiceFailure", 2204 { 2205 "Indicates that a service has exited unsuccessfully.", 2206 "Service %1 has exited unsuccessfully.", 2207 "Warning", 2208 1, 2209 { 2210 "string", 2211 }, 2212 "None.", 2213 }}, 2214 MessageEntry{ 2215 "ServiceStarted", 2216 { 2217 "Indicates that a service has started successfully.", 2218 "Service %1 has started successfully.", 2219 "OK", 2220 1, 2221 { 2222 "string", 2223 }, 2224 "None.", 2225 }}, 2226 MessageEntry{ 2227 "SparingRedundancyDegraded", 2228 { 2229 "Indicates the sparing redundancy state is degraded.", 2230 "Sparing redundancy state degraded. Socket=%1 Channel=%2 DIMM=%3 Domain=%4 Rank=%5.", 2231 "Warning", 2232 5, 2233 { 2234 "number", 2235 "string", 2236 "number", 2237 "string", 2238 "number", 2239 }, 2240 "None.", 2241 }}, 2242 MessageEntry{ 2243 "SparingRedundancyFull", 2244 { 2245 "Indicates the sparing redundancy state is fully redundant.", 2246 "Sparing redundancy state fully redundant. Socket=%1 Channel=%2 DIMM=%3 Domain=%4 Rank=%5.", 2247 "OK", 2248 5, 2249 { 2250 "number", 2251 "string", 2252 "number", 2253 "string", 2254 "number", 2255 }, 2256 "None.", 2257 }}, 2258 MessageEntry{ 2259 "SsbThermalTrip", 2260 { 2261 "Indicates that an SSB Thermal trip has been asserted.", 2262 "SSB Thermal trip.", 2263 "Critical", 2264 0, 2265 {}, 2266 "None.", 2267 }}, 2268 MessageEntry{ 2269 "SystemInterfaceDisabledProvisioned", 2270 { 2271 "Indicates that the system interface is in the disabled provisioned state. All commands are blocked to execute through the system interface.", 2272 "The system interface is in the disabled provisioned state.", 2273 "OK", 2274 0, 2275 {}, 2276 "None.", 2277 }}, 2278 MessageEntry{ 2279 "SystemInterfaceUnprovisioned", 2280 { 2281 "Indicates that the system interface is in the unprovisioned state. All commands are permitted to execute through the system interface.", 2282 "The system interface is in the unprovisioned state.", 2283 "Critical", 2284 0, 2285 {}, 2286 "None.", 2287 }}, 2288 MessageEntry{ 2289 "SystemInterfaceWhitelistProvisioned", 2290 { 2291 "Indicates that the system interface is in the whitelist provisioned state. Only whitelisted commands are permitted to execute through the system interface.", 2292 "The system interface is in the whitelist provisioned state.", 2293 "Warning", 2294 0, 2295 {}, 2296 "None.", 2297 }}, 2298 MessageEntry{ 2299 "SystemPowerGoodFailed", 2300 { 2301 "Indicates that the system power good signal failed to assert within the specified time (VR failure).", 2302 "System power good failed to assert within %1 milliseconds (VR failure).", 2303 "Critical", 2304 1, 2305 { 2306 "number", 2307 }, 2308 "None.", 2309 }}, 2310 MessageEntry{ 2311 "SystemPowerLost", 2312 { 2313 "Indicates that power was lost while the system was powered on.", 2314 "System Power Lost.", 2315 "Critical", 2316 0, 2317 {}, 2318 "None.", 2319 }}, 2320 MessageEntry{ 2321 "SystemPowerOffFailed", 2322 { 2323 "Indicates that the system failed to power off.", 2324 "System Power-Off Failed.", 2325 "Critical", 2326 0, 2327 {}, 2328 "None.", 2329 }}, 2330 MessageEntry{ 2331 "SystemPowerOnFailed", 2332 { 2333 "Indicates that the system failed to power on.", 2334 "System Power-On Failed.", 2335 "Critical", 2336 0, 2337 {}, 2338 "None.", 2339 }}, 2340 MessageEntry{ 2341 "VoltageRegulatorOverheated", 2342 { 2343 "Indicates that the specified voltage regulator overheated.", 2344 "%1 Voltage Regulator Overheated.", 2345 "Critical", 2346 1, 2347 { 2348 "string", 2349 }, 2350 "None.", 2351 }}, 2352 2353 }; 2354 2355 enum class Index 2356 { 2357 aDDDCCorrectable = 0, 2358 atScaleDebugConnected = 1, 2359 atScaleDebugConnectionFailed = 2, 2360 atScaleDebugDisconnected = 3, 2361 atScaleDebugFeatureDisabled = 4, 2362 atScaleDebugFeatureDisabledAtHardware = 5, 2363 atScaleDebugFeatureEnabled = 6, 2364 atScaleDebugFeatureEnabledAtHardware = 7, 2365 atScaleDebugSpecialUserDisabled = 8, 2366 atScaleDebugSpecialUserEnabled = 9, 2367 bIOSAttributesChanged = 10, 2368 bIOSBoot = 11, 2369 bIOSFirmwarePanicReason = 12, 2370 bIOSFirmwareRecoveryReason = 13, 2371 bIOSFirmwareResiliencyError = 14, 2372 bIOSPOSTCode = 15, 2373 bIOSPOSTError = 16, 2374 bIOSRecoveryComplete = 17, 2375 bIOSRecoveryStart = 18, 2376 bMCBootReason = 19, 2377 bMCFirmwarePanicReason = 20, 2378 bMCFirmwareRecoveryReason = 21, 2379 bMCFirmwareResiliencyError = 22, 2380 bMCKernelPanic = 23, 2381 cPLDFirmwarePanicReason = 24, 2382 cPLDFirmwareRecoveryReason = 25, 2383 cPLDFirmwareResiliencyError = 26, 2384 cPUError = 27, 2385 cPUMismatch = 28, 2386 cPUThermalTrip = 29, 2387 chassisIntrusionDetected = 30, 2388 chassisIntrusionReset = 31, 2389 componentOverTemperature = 32, 2390 dCPowerOff = 33, 2391 dCPowerOn = 34, 2392 driveError = 35, 2393 eventLogCleared = 36, 2394 fanInserted = 37, 2395 fanRedundancyLost = 38, 2396 fanRedundancyRegained = 39, 2397 fanRemoved = 40, 2398 firmwareActivationCompleted = 41, 2399 firmwareActivationFailed = 42, 2400 firmwareActivationStarted = 43, 2401 firmwareResiliencyError = 44, 2402 firmwareUpdateCompleted = 45, 2403 firmwareUpdateFailed = 46, 2404 firmwareUpdateStaged = 47, 2405 firmwareUpdateStarted = 48, 2406 generalFirmwareSecurityViolation = 49, 2407 iPMIWatchdog = 50, 2408 intelUPILinkWidthReducedToHalf = 51, 2409 intelUPILinkWidthReducedToQuarter = 52, 2410 invalidLoginAttempted = 53, 2411 invalidUpload = 54, 2412 inventoryAdded = 55, 2413 inventoryRemoved = 56, 2414 lanLost = 57, 2415 lanRegained = 58, 2416 legacyPCIPERR = 59, 2417 legacyPCISERR = 60, 2418 mEAutoConfigFailed = 61, 2419 mEAutoConfigSuccess = 62, 2420 mEBootGuardHealthEvent = 63, 2421 mECpuDebugCapabilityDisabled = 64, 2422 mEDirectFlashUpdateRequested = 65, 2423 mEExceptionDuringShutdown = 66, 2424 mEFactoryResetError = 67, 2425 mEFactoryRestore = 68, 2426 mEFirmwareException = 69, 2427 mEFirmwarePanicReason = 70, 2428 mEFirmwareRecoveryReason = 71, 2429 mEFirmwareResiliencyError = 72, 2430 mEFlashEraseError = 73, 2431 mEFlashStateInformation = 74, 2432 mEFlashStateInformationWritingEnabled = 75, 2433 mEFlashVerificationError = 76, 2434 mEFlashWearOutWarning = 77, 2435 mEImageExecutionFailed = 78, 2436 mEInternalError = 79, 2437 mEManufacturingError = 80, 2438 mEMctpInterfaceError = 81, 2439 mEMultiPchModeMisconfig = 82, 2440 mEPeciOverDmiError = 83, 2441 mEPttHealthEvent = 84, 2442 mERecoveryGpioForced = 85, 2443 mERestrictedMode = 86, 2444 mESmbusLinkFailure = 87, 2445 mEUmaError = 88, 2446 mEUnsupportedFeature = 89, 2447 manufacturingModeEntered = 90, 2448 manufacturingModeExited = 91, 2449 memoryECCCorrectable = 92, 2450 memoryECCUncorrectable = 93, 2451 memoryParityCommandAndAddress = 94, 2452 memoryParityNotKnown = 95, 2453 memoryRASConfigurationDisabled = 96, 2454 memoryRASConfigurationEnabled = 97, 2455 memoryRASModeDisabled = 98, 2456 memoryRASModeEnabled = 99, 2457 memoryThermTrip = 100, 2458 mirroringRedundancyDegraded = 101, 2459 mirroringRedundancyFull = 102, 2460 nMIButtonPressed = 103, 2461 nMIDiagnosticInterrupt = 104, 2462 pCIeCorrectableAdvisoryNonFatal = 105, 2463 pCIeCorrectableBadDLLP = 106, 2464 pCIeCorrectableBadTLP = 107, 2465 pCIeCorrectableHeaderLogOverflow = 108, 2466 pCIeCorrectableInternal = 109, 2467 pCIeCorrectableLinkBWChanged = 110, 2468 pCIeCorrectableReceiverError = 111, 2469 pCIeCorrectableReplayNumRollover = 112, 2470 pCIeCorrectableReplayTimerTimeout = 113, 2471 pCIeCorrectableUnspecifiedAERError = 114, 2472 pCIeFatalACSViolation = 115, 2473 pCIeFatalAtomicEgressBlocked = 116, 2474 pCIeFatalCompleterAbort = 117, 2475 pCIeFatalCompletionTimeout = 118, 2476 pCIeFatalDataLinkLayerProtocol = 119, 2477 pCIeFatalECRCError = 120, 2478 pCIeFatalFlowControlProtocol = 121, 2479 pCIeFatalMCBlockedTLP = 122, 2480 pCIeFatalMalformedTLP = 123, 2481 pCIeFatalPoisonedTLP = 124, 2482 pCIeFatalReceivedErrNonFatalMessage = 125, 2483 pCIeFatalReceivedFatalMessageFromDownstream = 126, 2484 pCIeFatalReceiverBufferOverflow = 127, 2485 pCIeFatalSurpriseLinkDown = 128, 2486 pCIeFatalTLPPrefixBlocked = 129, 2487 pCIeFatalUncorrectableInternal = 130, 2488 pCIeFatalUnexpectedCompletion = 131, 2489 pCIeFatalUnspecifiedNonAERFatalError = 132, 2490 pCIeFatalUnsupportedRequest = 133, 2491 powerButtonLongPressed = 134, 2492 powerButtonPressed = 135, 2493 powerRestorePolicyApplied = 136, 2494 powerSupplyConfigurationError = 137, 2495 powerSupplyConfigurationErrorRecovered = 138, 2496 powerSupplyFailed = 139, 2497 powerSupplyFailurePredicted = 140, 2498 powerSupplyFanFailed = 141, 2499 powerSupplyFanRecovered = 142, 2500 powerSupplyInserted = 143, 2501 powerSupplyPowerGoodFailed = 144, 2502 powerSupplyPowerLost = 145, 2503 powerSupplyPowerRestored = 146, 2504 powerSupplyPredictedFailureRecovered = 147, 2505 powerSupplyRecovered = 148, 2506 powerSupplyRemoved = 149, 2507 powerUnitDegradedFromNonRedundant = 150, 2508 powerUnitDegradedFromRedundant = 151, 2509 powerUnitNonRedundantFromInsufficient = 152, 2510 powerUnitNonRedundantInsufficient = 153, 2511 powerUnitNonRedundantSufficient = 154, 2512 powerUnitRedundancyDegraded = 155, 2513 powerUnitRedundancyLost = 156, 2514 powerUnitRedundancyRegained = 157, 2515 resetButtonPressed = 158, 2516 sELEntryAdded = 159, 2517 securityBoot2ndFlashEnabled = 160, 2518 securityP2aBridgeEnabled = 161, 2519 securityUartPortDebugEnabled = 162, 2520 securityUserNonRootUidZeroAssigned = 163, 2521 securityUserNonRootUidZeroRemoved = 164, 2522 securityUserRootDisabled = 165, 2523 securityUserRootEnabled = 166, 2524 securityUserStrongHashAlgoRestored = 167, 2525 securityUserUnsupportedShellEnabled = 168, 2526 securityUserUnsupportedShellRemoved = 169, 2527 securityUserWeakHashAlgoEnabled = 170, 2528 sensorThresholdCriticalHighGoingHigh = 171, 2529 sensorThresholdCriticalHighGoingLow = 172, 2530 sensorThresholdCriticalLowGoingHigh = 173, 2531 sensorThresholdCriticalLowGoingLow = 174, 2532 sensorThresholdWarningHighGoingHigh = 175, 2533 sensorThresholdWarningHighGoingLow = 176, 2534 sensorThresholdWarningLowGoingHigh = 177, 2535 sensorThresholdWarningLowGoingLow = 178, 2536 serviceFailure = 179, 2537 serviceStarted = 180, 2538 sparingRedundancyDegraded = 181, 2539 sparingRedundancyFull = 182, 2540 ssbThermalTrip = 183, 2541 systemInterfaceDisabledProvisioned = 184, 2542 systemInterfaceUnprovisioned = 185, 2543 systemInterfaceWhitelistProvisioned = 186, 2544 systemPowerGoodFailed = 187, 2545 systemPowerLost = 188, 2546 systemPowerOffFailed = 189, 2547 systemPowerOnFailed = 190, 2548 voltageRegulatorOverheated = 191, 2549 }; 2550 } // namespace redfish::registries::openbmc 2551