# log_phase_fault ## Description Logs a redundant phase fault error for a voltage regulator. This action should be executed if a fault is detected during [phase_fault_detection](phase_fault_detection.md) for the regulator. A regulator may contain one or more redundant phases: - An "N+2" regulator has two redundant phases - An "N+1" regulator has one redundant phase A phase fault occurs when a phase stops functioning properly. The redundancy level of the regulator is reduced. The phase fault type indicates the level of redundancy remaining **after** the fault has occurred: | Type | Description | | :--- | :----------------------------------------------------------------------------------------------- | | n+1 | An "N+2" regulator has lost one redundant phase. The regulator is now at redundancy level "N+1". | | n | Regulator has lost all redundant phases. The regulator is now at redundancy level N. | If additional data about the fault was previously captured using [i2c_capture_bytes](i2c_capture_bytes.md), that data will be stored in the error log. ## Properties | Name | Required | Type | Description | | :--- | :------: | :----- | :---------------------------------------------------------- | | type | yes | string | Phase fault type. Specify one of the following: "n+1", "n". | ## Return Value true ## Example ```json { "log_phase_fault": { "type": "n+1" } } ```