{ "comments": [ "phosphor-regulators configuration file for IBM Everest systems" ], "rules": [ { "comments": ["Rule to set PMBus PAGE to 0"], "id": "set_page0_rule", "actions": [ { "i2c_write_byte": { "register": "0x00", "value": "0x00" } } ] }, { "comments": ["Rule to set PMBus PAGE to 1"], "id": "set_page1_rule", "actions": [ { "i2c_write_byte": { "register": "0x00", "value": "0x01" } } ] }, { "comments": ["Rule to set output voltage of a PMBus regulator"], "id": "set_voltage_rule", "actions": [ { "comments": [ "Write volts value to VOUT_COMMAND in linear format.", "Get volts value from configuration. Get exponent", "from VOUT_MODE. Verify write was successful." ], "pmbus_write_vout_command": { "format": "linear", "is_verified": true } } ] }, { "comments": [ "Rule to set output voltage of PAGE 0 of a PMBus regulator" ], "id": "set_voltage_page0_rule", "actions": [ { "run_rule": "set_page0_rule" }, { "run_rule": "set_voltage_rule" } ] }, { "comments": [ "Rule to set output voltage of PAGE 1 of a PMBus regulator" ], "id": "set_voltage_page1_rule", "actions": [ { "run_rule": "set_page1_rule" }, { "run_rule": "set_voltage_rule" } ] }, { "comments": [ "Rule to set output voltage of a PMBus regulator using", "PMBus OPERATION and VOUT_COMMAND" ], "id": "set_operation_and_voltage_rule", "actions": [ { "comments": [ "Set PMBus OPERATION to 0x80 indicating output voltage", "is set by the PMBus VOUT_COMMAND" ], "i2c_write_byte": { "register": "0x01", "value": "0x80" } }, { "comments": [ "Set the output voltage using the PMBus VOUT_COMMAND" ], "run_rule": "set_voltage_rule" }, { "comments": [ "Set PMBus OPERATION to 0xB0 indicating output voltage", "will now be set by AVSBus (AVS_VOUT_COMMAND).", "Hardware settings cause the VOUT_COMMAND value to be", "the initial voltage value for AVSBus." ], "i2c_write_byte": { "register": "0x01", "value": "0xB0" } } ] } ], "chassis": [ { "comments": ["Chassis (drawer) 1", "Note: Devices not defined yet"], "number": 1, "inventory_path": "system/chassis" } ] }