# num_nonfunc_rotors_before_error ## Description The number of fan rotors (also known as [`sensors`](sensors.md)) that must be deemed nonfunctional for an error event log to be created. When the number of nonfunctional fan rotors are below this value, informational event logs are created against those nonfunctional fan rotors. This attribute is optional and defaults to 1, meaning an error event log should be created when any one of the fan rotors([`sensors`](sensors.md)) being monitored is nonfunctional. ## Attribute Value(s) integer (default = 1) ## Example

{
  "fault_handling": [
    {
      "num_nonfunc_rotors_before_error": 1,
      "power_off_config": [
        {
          "type": "hard",
          "cause": "missing_fan_frus",
          "count": 1,
          "delay": 25,
          "state": "at_pgood"
        },
        {
          "type": "soft",
          "cause": "nonfunc_fan_rotors",
          "count": 2,
          "delay": 30,
          "state": "runtime"
        },
        {
          "type": "epow",
          "cause": "nonfunc_fan_rotors",
          "count": 3,
          "service_mode_delay": 300,
          "meltdown_delay": 300
        }
      ]
    }
  ]
}