# https://github.com/openbmc/openbmc-test-automation/issues/822 --exclude Verify_Minimal_Memory_Buffer_Inventory --exclude Verify_Minimal_Main_Planar_Inventory --exclude Verify_Minimal_System_Inventory # NA test case for Witherspoon --exclude io_board_Present --exclude io_board_Fault # System LED test cases which are NA for Witherspoon system. --exclude Test_Heartbeat_LED_And_Verify_Via_REST --exclude Test_Beep_LED_And_Verify_Via_REST --exclude Test_Identify_LED_And_Verify_Via_REST # NXDMAENG UE error injection is not available in latest p9dd1ffdcv104.xlsm --exclude Verify_Unrecoverable_Callout_Handling_For_NXDMAENG # NA test case with nginx support. --exclude Test_Non_SSL_Connection_To_Port_80 --exclude Test_Non_SSL_Connection_To_Port_443 # MRW changes required for this to work. --exclude Test_GPU_SDR_Info_At_Power_On # Core dump is disabled. --exclude Verify_Core_Dump_Size # Skip org code update. --exclude Initiate_Code_Update_BMC --exclude BIOS_Code_Update --exclude Redfish_Image_Upload --exclude Bmc_Code_Update --exclude Redfish_Host_Code_Update --exclude BMC_Update_Recoverable_Error --exclude Host_Update_Recoverable_Error --exclude BMC_Multi_Code_Update --exclude Host_Multi_Code_Update --exclude Verify_IPMI_Disable_Policy_Post_BMC_Code_Update # Others NA tests. --exclude Run_Keyword_Pgm # Factory reset must not run in CT. --exclude Factory_Reset --exclude Full_Suite_Regression --exclude AC_Cycles --exclude Network_Nping # Multiple runs only needed for stability. --exclude Run_Multiple_Power_Cycle --exclude Run_Multiple_BMC_Reset_Via_REST --exclude Run_Multiple_BMC_Reset_Via_Reboot --exclude General_boot_testing --exclude SLP_Service_Test --exclude Check_Network_Latency # Configure invalid IP address use cases. --exclude Configure_Broadcast_IP --exclude Configure_Multicast_IP --exclude Configure_Loopback_IP --exclude Configure_Network_ID # Invalid gateway address configuration. --exclude Configure_Broadcast_IP_For_Gateway --exclude Configure_Loopback_IP_For_Gateway --exclude Configure_Multicast_IP_For_Gateway --exclude Configure_Network_ID_For_Gateway --exclude Verify_Network_Interface_Recovery # Skipping RAS test cases --exclude Host_RAS # Skip multi threading test causing XML parser failure. --exclude Stress_BMC_REST_Server --exclude Stress_BMC_SSH_Server --exclude Stress_BMC_IPMI_Server # Applicable only for master build. --exclude Verify_eSEL_Description_And_EntryID_Using_REST # Needs fix and improvement. --exclude Test_SBE_Side_Switch # IPMI disable and enable use cases. --exclude Verify_Disabling_And_Enabling_IPMI_Via_Host --exclude Verify_Disabling_IPMI_Via_OOB_IPMI --exclude Verify_IPMI_Disable_Persistency_After_BMC_Reboot # Remote logging --exclude Verify_BMC_Journald_Contains_No_Credential_Data # Non bmcweb certificate. --exclude Certificate