*** Settings *** Documentation Test BMC multiple network interface functionalities. # User input BMC IP for the eth1. # Use can input as -v OPENBMC_HOST_1:xx.xxx.xx from command line. Library ../../lib/bmc_redfish.py https://${OPENBMC_HOST_1}:${HTTPS_PORT} ... ${OPENBMC_USERNAME} ${OPENBMC_PASSWORD} WITH NAME Redfish1 Resource ../../lib/resource.robot Resource ../../lib/common_utils.robot Resource ../../lib/connection_client.robot Resource ../../lib/bmc_network_utils.robot Resource ../../lib/openbmc_ffdc.robot Resource ../../lib/bmc_ldap_utils.robot Resource ../../lib/snmp/resource.robot Resource ../../lib/snmp/redfish_snmp_utils.robot Resource ../../lib/certificate_utils.robot Library ../../lib/jobs_processing.py Library OperatingSystem Suite Setup Suite Setup Execution Test Teardown FFDC On Test Case Fail Suite Teardown Run Keywords Redfish1.Logout AND Redfish.Logout *** Variables *** ${cmd_prefix} ipmitool -I lanplus -C 17 -p 623 -U ${OPENBMC_USERNAME} -P ${OPENBMC_PASSWORD} ${test_ipv4_addr} 10.7.7.7 ${test_ipv4_addr2} 10.7.7.8 ${test_subnet_mask} 255.255.255.0 *** Test Cases *** Verify Both Interfaces BMC IP Addresses Accessible Via SSH [Documentation] Verify both interfaces (eth0, eth1) BMC IP addresses accessible via SSH. [Tags] Verify_Both_Interfaces_BMC_IP_Addresses_Accessible_Via_SSH Open Connection And Log In ${OPENBMC_USERNAME} ${OPENBMC_PASSWORD} host=${OPENBMC_HOST} Open Connection And Log In ${OPENBMC_USERNAME} ${OPENBMC_PASSWORD} host=${OPENBMC_HOST_1} Close All Connections Verify Redfish Works On Both Interfaces [Documentation] Verify access BMC with both interfaces (eth0, eth1) IP addresses via Redfish. [Tags] Verify_Redfish_Works_On_Both_Interfaces [Teardown] Run Keywords ... Configure Hostname ${hostname} AND Validate Hostname On BMC ${hostname} Redfish1.Login Redfish.Login ${hostname}= Redfish.Get Attribute ${REDFISH_NW_PROTOCOL_URI} HostName ${data}= Create Dictionary HostName=openbmc Redfish1.patch ${REDFISH_NW_ETH_IFACE}eth1 body=&{data} ... valid_status_codes=[${HTTP_OK}, ${HTTP_NO_CONTENT}] Validate Hostname On BMC openbmc ${resp1}= Redfish.Get ${REDFISH_NW_ETH_IFACE}eth0 ${resp2}= Redfish1.Get ${REDFISH_NW_ETH_IFACE}eth1 Should Be Equal ${resp1.dict['HostName']} ${resp2.dict['HostName']} Verify LDAP Login Works When Eth1 IP Is Not Configured [Documentation] Verify LDAP login works when eth1 IP is erased. [Tags] Verify_LDAP_Login_Works_When_Eth1_IP_Is_Not_Configured [Setup] Run Keywords Set Test Variable ${CHANNEL_NUMBER} ${2} ... AND Delete IP Address ${OPENBMC_HOST_1} ... AND Redfish.Login [Teardown] Run Keywords Redfish.Logout AND ... Add IP Address ${OPENBMC_HOST_1} ${eth1_subnet_mask} ${eth1_gateway} Create LDAP Configuration Redfish.Logout Redfish.Login ${LDAP_USER} ${LDAP_USER_PASSWORD} Verify LDAP Login Works When Both Interfaces Are Configured [Documentation] Verify LDAP login works when both interfaces are configured. [Tags] Verify_LDAP_Login_Works_When_Both_Interfaces_Are_Configured [Setup] Redfish.Login [Teardown] Redfish.Logout Create LDAP Configuration Redfish.Logout Redfish.Login ${LDAP_USER} ${LDAP_USER_PASSWORD} Verify Secure LDAP Login Works When Both Interfaces Are Configured [Documentation] Verify Secure LDAP login works when both the interfaces are configured. [Tags] Verify_Secure_LDAP_Login_Works_When_Both_Interfaces_Are_Configured [Setup] Redfish.Login [Teardown] Redfish.Logout Create LDAP Configuration ${LDAP_TYPE} ${LDAP_SERVER_URI_1} ${LDAP_BIND_DN} ... ${LDAP_BIND_DN_PASSWORD} ${LDAP_BASE_DN} Redfish.Logout Redfish.Login ${LDAP_USER} ${LDAP_USER_PASSWORD} Verify SNMP Works When Eth1 IP Is Not Configured [Documentation] Verify SNMP works when eth1 IP is not configured. [Tags] Verify_SNMP_Works_When_Eth1_IP_Is_Not_Configured [Setup] Run Keywords Set Test Variable ${CHANNEL_NUMBER} ${2} ... AND Delete IP Address ${OPENBMC_HOST_1} [Teardown] Run Keywords Redfish.Login AND ... Add IP Address ${OPENBMC_HOST_1} ${eth1_subnet_mask} ${eth1_gateway} Create Error On BMC And Verify Trap Disable And Enable Eth0 Interface [Documentation] Disable and Enable eth0 ethernet interface via redfish. [Tags] Disable_And_Enable_Eth0_Interface [Template] Set BMC Ethernet Interfaces State # interface_ip interface enabled ${OPENBMC_HOST} eth0 ${False} ${OPENBMC_HOST} eth0 ${True} Verify Both Interfaces Access Concurrently Via Redfish [Documentation] Verify both interfaces access conurrently via redfish. [Tags] Verify_Both_Interfaces_Access_Concurrently_Via_Redfish Redfish.Login Redfish1.Login ${dict}= Execute Process Multi Keyword ${2} ... Redfish.Patch ${REDFISH_NW_ETH_IFACE}eth0 body={'DHCPv4':{'UseDNSServers':${True}}} ... Redfish1.Patch ${REDFISH_NW_ETH_IFACE}eth1 body={'DHCPv4':{'UseDNSServers':${True}}} Dictionary Should Not Contain Value ${dict} False ... msg=One or more operations has failed. ${resp}= Redfish.Get ${REDFISH_NW_ETH_IFACE}eth0 ${resp1}= Redfish1.Get ${REDFISH_NW_ETH_IFACE}eth1 Should Be Equal ${resp.dict["DHCPv4"]['UseDNSServers']} ${True} Should Be Equal ${resp1.dict["DHCPv4"]['UseDNSServers']} ${True} Able To Access Serial Console Via Both Network Interfaces [Documentation] Able to access serial console via both network interfaces. [Tags] Able_To_Access_Serial_Console_Via_Both_Network_Interfaces Open Connection And Log In host=${OPENBMC_HOST} port=2200 Open Connection And Log In host=${OPENBMC_HOST_1} port=2200 Close All Connections Verify IPMI Works On Both Network Interfaces [Documentation] Verify IPMI works on both network interfaces. [Tags] Verify_IPMI_Works_On_Both_Network_Interfaces Run IPMI ${OPENBMC_HOST_1} power on ${status1}= Run IPMI ${OPENBMC_HOST} power status ${status2}= Run IPMI ${OPENBMC_HOST_1} power status Should Be Equal ${status1} ${status2} Verify Modifying IP Address Multiple Times On Interface [Documentation] Verify modifying IP address multiple times on interface. [Tags] Verify_Modifying_IP_Address_Multiple_Times_On_Interface [Teardown] Run Keywords ... Delete IP Address ${test_ipv4_addr} AND Test Teardown ${test_gateway}= Get BMC Default Gateway Add IP Address ${test_ipv4_addr} ${test_subnet_mask} ${test_gateway} Update IP Address ${test_ipv4_addr} ${test_ipv4_addr2} ${test_subnet_mask} ${test_gateway} Update IP Address ${test_ipv4_addr2} ${test_ipv4_addr} ${test_subnet_mask} ${test_gateway} Run Keyword Wait For Host To Ping ${OPENBMC_HOST} ${NETWORK_TIMEOUT} Run Keyword Wait For Host To Ping ${OPENBMC_HOST_1} ${NETWORK_TIMEOUT} Verify Able To Load Certificates Via Eth1 IP Address [Documentation] Verify able to load certificates via eth1 IP address. [Setup] Create Directory certificate_dir [Tags] Verify_Able_To_Load_Certificates_Via_Eth1_IP_Address [Teardown] Run Keywords Remove Directory certificate_dir recursive=True ... AND FFDC On Test Case Fail [Template] Install Certificate Via Redfish And Verify # cert_type cert_format expected_status CA Valid Certificate ok Client Valid Certificate Valid Privatekey ok *** Keywords *** Get Network Configuration Using Channel Number [Documentation] Get ethernet interface. [Arguments] ${channel_number} # Description of argument(s): # channel_number Ethernet channel number, 1 is for eth0 and 2 is for eth1 (e.g. "1"). ${active_channel_config}= Get Active Channel Config ${ethernet_interface}= Set Variable ${active_channel_config['${channel_number}']['name']} ${resp}= Redfish.Get ${REDFISH_NW_ETH_IFACE}${ethernet_interface} @{network_configurations}= Get From Dictionary ${resp.dict} IPv4StaticAddresses [Return] @{network_configurations} Suite Setup Execution [Documentation] Do suite setup task. Valid Value OPENBMC_HOST_1 # Check both interfaces are configured and reachable. Ping Host ${OPENBMC_HOST} Ping Host ${OPENBMC_HOST_1} ${network_configurations}= Get Network Configuration Using Channel Number ${2} FOR ${network_configuration} IN @{network_configurations} Run Keyword If '${network_configuration['Address']}' == '${OPENBMC_HOST_1}' ... Run Keywords Set Suite Variable ${eth1_subnet_mask} ${network_configuration['SubnetMask']} ... AND Set Suite Variable ${eth1_gateway} ${network_configuration['Gateway']} ... AND Exit For Loop END Set BMC Ethernet Interfaces State [Documentation] Set BMC ethernet interface state. [Arguments] ${interface_ip} ${interface} ${enabled} [Teardown] Redfish1.Logout # Description of argument(s): # interface_ip IP address of ethernet interface. # interface The ethernet interface name (eg. eth0 or eth1). # enabled Indicates interface should be enabled (eg. True or False). Redfish1.Login ${data}= Create Dictionary InterfaceEnabled=${enabled} Redfish1.patch ${REDFISH_NW_ETH_IFACE}${interface} body=&{data} ... valid_status_codes=[${HTTP_OK}, ${HTTP_NO_CONTENT}] Sleep ${NETWORK_TIMEOUT}s ${interface_status}= Redfish1.Get Attribute ${REDFISH_NW_ETH_IFACE}${interface} InterfaceEnabled Should Be Equal ${interface_status} ${enabled} ${status}= Run Keyword And Return Status Ping Host ${interface_ip} Run Keyword If ${enabled} == ${True} Should Be Equal ${status} ${True} ... ELSE Should Be Equal ${status} ${False} Run IPMI [Documentation] Run IPMI command. [Arguments] ${host} ${sub_cmd} # Description of argument(s): # host BMC host name or IP address. # sub_cmd The IPMI command string to be executed. ${rc} ${output}= Run And Return Rc And Output ${cmd_prefix} -H ${host} ${sub_cmd} Should Be Equal As Strings ${rc} 0 [Return] ${output} Install Certificate Via Redfish And Verify [Documentation] Install and verify certificate using Redfish. [Arguments] ${cert_type} ${cert_format} ${expected_status} ${delete_cert}=${True} # Description of argument(s): # cert_type Certificate type (e.g. "Client" or "CA"). # cert_format Certificate file format # (e.g. "Valid_Certificate_Valid_Privatekey"). # expected_status Expected status of certificate replace Redfish # request (i.e. "ok" or "error"). # delete_cert Certificate will be deleted before installing if this True. # AUTH_URI is a global variable defined in lib/resource.robot Set Test Variable ${AUTH_URI} https://${OPENBMC_HOST_1} Run Keyword If '${cert_type}' == 'CA' and '${delete_cert}' == '${True}' ... Delete All CA Certificate Via Redfish ... ELSE IF '${cert_type}' == 'Client' and '${delete_cert}' == '${True}' ... Delete Certificate Via BMC CLI ${cert_type} ${cert_file_path}= Generate Certificate File Via Openssl ${cert_format} ${bytes}= OperatingSystem.Get Binary File ${cert_file_path} ${file_data}= Decode Bytes To String ${bytes} UTF-8 ${certificate_uri}= Set Variable If ... '${cert_type}' == 'Client' ${REDFISH_LDAP_CERTIFICATE_URI} ... '${cert_type}' == 'CA' ${REDFISH_CA_CERTIFICATE_URI} ${cert_id}= Install Certificate File On BMC ${certificate_uri} ${expected_status} data=${file_data} Logging Installed certificate id: ${cert_id} Sleep 30s ${cert_file_content}= OperatingSystem.Get File ${cert_file_path} ${bmc_cert_content}= Run Keyword If '${expected_status}' == 'ok' redfish_utils.Get Attribute ... ${certificate_uri}/${cert_id} CertificateString Run Keyword If '${expected_status}' == 'ok' Should Contain ${cert_file_content} ${bmc_cert_content} [Return] ${cert_id}