*** Settings *** Documentation This suite tests error log callout handling when checkstop ... is injected through HOST/BMC and BMC rebooted. Resource ../../lib/openbmc_ffdc.robot Resource ../../lib/openbmc_ffdc_utils.robot Resource ../../lib/openbmc_ffdc_methods.robot Resource ../../openpower/ras/ras_utils.robot Variables ../../lib/ras/variables.py Variables ../../data/variables.py Suite Setup RAS Suite Setup Test Setup RAS Test Setup Test Teardown FFDC On Test Case Fail Suite Teardown RAS Suite Cleanup Test Tags Reboot_RAS *** Test Cases *** Verify Host Unrecoverable Callout Handling At Reboot [Documentation] Verify host unrecoverable callout handling at reboot. [Tags] Verify_Host_Unrecoverable_Callout_Handling_At_Reboot ${value}= Get From Dictionary ${ERROR_INJECT_DICT} L2FIR_UE ${translated_fir}= Fetch FIR Address Translation Value ${value[0]} EX ${err_log_path}= Catenate ${RAS_LOG_DIR_PATH}l2fir_ue Inject Unrecoverable Error HOST ${translated_fir} ... ${value[1]} 1 ${value[2]} ${err_log_path} ${1} Verify Pdbg Unrecoverable Callout Handling At Reboot [Documentation] Verify unrecoverable callout handling ... with pdbg tool at reboot. [Tags] Verify_Pdbg_Unrecoverable_Callout_Handling_At_Reboot ${value}= Get From Dictionary ${ERROR_INJECT_DICT} L3FIR_UE ${translated_fir}= Fetch FIR Address Translation Value ${value[0]} EX ${err_log_path}= Catenate ${RAS_LOG_DIR_PATH}l3fir_ue Inject Unrecoverable Error BMC ${translated_fir} ... ${value[1]} 1 ${value[2]} ${err_log_path} ${1}