*** Settings *** Documentation Error logging utility keywords. Resource rest_client.robot Resource bmc_redfish_utils.robot Variables ../data/variables.py Variables ../data/pel_variables.py *** Variables *** # Define variables for use by callers of 'Get Error Logs'. ${low_severity_errlog_regex} \\.(Informational|Notice|Debug|OK)$ &{low_severity_errlog_filter} Severity=${low_severity_errlog_regex} &{low_severity_errlog_filter_args} filter_dict=${low_severity_errlog_filter} regex=${True} invert=${True} # The following is equivalent to &{low_severity_errlog_filter_args} but the name may be more intuitive for # users. Example usage: # ${err_logs}= Get Error Logs &{filter_low_severity_errlogs} &{filter_low_severity_errlogs} &{low_severity_errlog_filter_args} *** Keywords *** Get Logging Entry List [Documentation] Get logging entry and return the object list. ${entry_list}= Create List ${resp}= OpenBMC Get Request ${BMC_LOGGING_ENTRY}list quiet=${1} Return From Keyword If ${resp.status_code} == ${HTTP_NOT_FOUND} ${jsondata}= To JSON ${resp.content} FOR ${entry} IN @{jsondata["data"]} Continue For Loop If '${entry.rsplit('/', 1)[1]}' == 'callout' Append To List ${entry_list} ${entry} END # Logging entries list. # ['/xyz/openbmc_project/logging/entry/14', # '/xyz/openbmc_project/logging/entry/15'] [Return] ${entry_list} Logging Entry Should Exist [Documentation] Find the matching message id and return the entry id. [Arguments] ${message_id} # Description of argument(s): # message_id Logging message string. # Example: "xyz.openbmc_project.Common.Error.InternalFailure" @{elog_entries}= Get Logging Entry List FOR ${entry} IN @{elog_entries} ${resp}= Read Properties ${entry} ${status}= Run Keyword And Return Status ... Should Be Equal As Strings ${message_id} ${resp["Message"]} Return From Keyword If ${status} == ${TRUE} ${entry} END Fail No ${message_id} logging entry found. Get Error Logs [Documentation] Return the BMC error logs as a dictionary. [Arguments] ${quiet}=1 &{filter_struct_args} # Example of call using pre-defined filter args (defined above). # ${err_logs}= Get Error Logs &{filter_low_severity_errlogs} # In this example, all error logs with "Severity" fields that are neither Informational, Debug nor # Notice will be returned. # Description of argument(s): # quiet Indicates whether this keyword should run without any output to the # console, 0 = verbose, 1 = quiet. # filter_struct_args filter_struct args (e.g. filter_dict, regex, etc.) to be passed directly # to the Filter Struct keyword. See its prolog for details. # The length of the returned dictionary indicates how many logs there are. # Use 'Print Error Logs' to print. Example: # Print Error Logs ${error_logs} Message. ${status} ${error_logs}= Run Keyword And Ignore Error Read Properties ... /xyz/openbmc_project/logging/entry/enumerate timeout=30 quiet=${quiet} Return From Keyword If '${status}' == 'FAIL' &{EMPTY} ${num_filter_struct_args}= Get Length ${filter_struct_args} Return From Keyword If '${num_filter_struct_args}' == '${0}' ${error_logs} ${filtered_error_logs}= Filter Struct ${error_logs} &{filter_struct_args} [Return] ${filtered_error_logs} Get IPMI SEL Setting [Documentation] Returns status for given IPMI SEL setting. [Arguments] ${setting} # Description of argument(s): # setting SEL setting which needs to be read(e.g. "Last Add Time"). ${resp}= Run IPMI Standard Command sel info ${setting_line}= Get Lines Containing String ${resp} ${setting} ... case-insensitive ${setting_status}= Fetch From Right ${setting_line} :${SPACE} [Return] ${setting_status} Verify Watchdog Errorlog Content [Documentation] Verify watchdog errorlog content. # Example: # "/xyz/openbmc_project/logging/entry/1": # { # "AdditionalData": [], # "Id": 1, # "Message": "org.open_power.Host.Boot.Error.WatchdogTimedOut", # "Resolved": 0, # "Severity": "xyz.openbmc_project.Logging.Entry.Level.Error", # "Timestamp": 1492715244828, # "Associations": [] # }, ${elog_entry}= Get URL List ${BMC_LOGGING_ENTRY} ${elog}= Read Properties ${elog_entry[0]} Should Be Equal As Strings ... ${elog["Message"]} org.open_power.Host.Boot.Error.WatchdogTimedOut ... msg=Watchdog timeout error log was not found. Should Be Equal As Strings ... ${elog["Severity"]} xyz.openbmc_project.Logging.Entry.Level.Error ... msg=Watchdog timeout severity unexpected value. Logging Test Binary Exist [Documentation] Verify existence of prerequisite logging-test. ${stdout} ${stderr} ${rc}= ... BMC Execute Command test -f /tmp/tarball/bin/logging-test print_out=1 Should Be Empty ${stderr} msg=Logging Test stderr is non-empty. Clear Existing Error Logs [Documentation] If error log isn't empty, reboot the BMC to clear the log. ${resp}= OpenBMC Get Request ${BMC_LOGGING_ENTRY}${1} Return From Keyword If ${resp.status_code} == ${HTTP_NOT_FOUND} Initiate BMC Reboot Wait Until Keyword Succeeds 10 min 10 sec ... Is BMC Ready ${resp}= OpenBMC Get Request ${BMC_LOGGING_ENTRY}${1} Should Be Equal As Strings ${resp.status_code} ${HTTP_NOT_FOUND} ... msg=Could not clear BMC error logs. Create Test PEL Log [Documentation] Generate test PEL log. [Arguments] ${pel_type}=Unrecoverable Error # Description of argument(s): # pel_type The PEL type (e.g. Internal Failure, FRU Callout, Procedural Callout). # Test PEL log entry example: # { # "0x5000002D": { # "SRC": "BD8D1002", # "Message": "An application had an internal failure", # "PLID": "0x5000002D", # "CreatorID": "BMC", # "Subsystem": "BMC Firmware", # "Commit Time": "02/25/2020 04:47:09", # "Sev": "Unrecoverable Error", # "CompID": "0x1000" # } # } Run Keyword If '${pel_type}' == 'Internal Failure' ... BMC Execute Command ${CMD_INTERNAL_FAILURE} ... ELSE IF '${pel_type}' == 'FRU Callout' ... BMC Execute Command ${CMD_FRU_CALLOUT} ... ELSE IF '${pel_type}' == 'Procedure And Symbolic FRU Callout' ... BMC Execute Command ${CMD_PROCEDURAL_SYMBOLIC_FRU_CALLOUT} ... ELSE IF '${pel_type}' == 'Unrecoverable Error' ... BMC Execute Command ${CMD_UNRECOVERABLE_ERROR} Create Test Error Log [Documentation] Generate test error log. # Test error log entry example: # "/xyz/openbmc_project/logging/entry/1": { # "AdditionalData": [ # "STRING=FOO" # ], # "Id": 1, # "Message": "example.xyz.openbmc_project.Example.Elog.AutoTestSimple", # "Severity": "xyz.openbmc_project.Logging.Entry.Level.Error", # "Timestamp": 1487743963328, # "Associations": [] # } BMC Execute Command /tmp/tarball/bin/logging-test -c AutoTestSimple Count Error Entries [Documentation] Count Error entries. ${resp}= OpenBMC Get Request ${BMC_LOGGING_ENTRY} Should Be Equal As Strings ${resp.status_code} ${HTTP_OK} ... msg=Failed to get error logs. ${jsondata}= To JSON ${resp.content} ${count}= Get Length ${jsondata["data"]} [Return] ${count} Verify Test Error Log [Documentation] Verify test error log entries. ${elog_entry}= Get URL List ${BMC_LOGGING_ENTRY} ${entry_id}= Read Attribute ${elog_entry[0]} Message Should Be Equal ${entry_id} ... example.xyz.openbmc_project.Example.Elog.AutoTestSimple ... msg=Error log not from AutoTestSimple. ${entry_id}= Read Attribute ${elog_entry[0]} Severity Should Be Equal ${entry_id} ... xyz.openbmc_project.Logging.Entry.Level.Error ... msg=Error log severity mismatch. Delete Error Logs And Verify [Documentation] Delete all error logs and verify. Delete All Error Logs ${resp}= OpenBMC Get Request ${BMC_LOGGING_ENTRY}list quiet=${1} Should Be Equal As Strings ${resp.status_code} ${HTTP_NOT_FOUND} ... msg=Error logs not deleted as expected. Install Tarball [Documentation] Install tarball on BMC. Should Not Be Empty ${DEBUG_TARBALL_PATH} ... msg=Debug tarball path value is required. BMC Execute Command rm -rf /tmp/tarball Install Debug Tarball On BMC ${DEBUG_TARBALL_PATH} Get Event Logs [Documentation] Get all available EventLog entries. #{ # "@odata.context": "/redfish/v1/$metadata#LogEntryCollection.LogEntryCollection", # "@odata.id": "/redfish/v1/Systems/system/LogServices/EventLog/Entries", # "@odata.type": "#LogEntryCollection.LogEntryCollection", # "Description": "Collection of System Event Log Entries", # "Members": [ # { # "@odata.context": "/redfish/v1/$metadata#LogEntry.LogEntry", # "@odata.id": "/redfish/v1/Systems/system/LogServices/EventLog/Entries/1", # "@odata.type": "#LogEntry.v1_4_0.LogEntry", # "Created": "2019-05-29T13:19:27+00:00", # "EntryType": "Event", # "Id": "1", # "Message": "org.open_power.Host.Error.Event", # "Name": "System DBus Event Log Entry", # "Severity": "Critical" # } # ], # "Members@odata.count": 1, # "Name": "System Event Log Entries" #} ${members}= Redfish.Get Attribute ${EVENT_LOG_URI}Entries Members [Return] ${members} Get Redfish Event Logs [Documentation] Pack the list of all available EventLog entries in dictionary. [Arguments] ${quiet}=1 &{filter_struct_args} # Description of argument(s): # quiet Indicates whether this keyword should run without any output to the # console, 0 = verbose, 1 = quiet. # filter_struct_args filter_struct args (e.g. filter_dict, regex, etc.) to be passed # directly to the Filter Struct keyword. See its prolog for details. ${packed_dict}= Create Dictionary ${error_logs}= Get Event Logs FOR ${idx} IN @{error_logs} Set To Dictionary ${packed_dict} ${idx['@odata.id']}=${idx} END ${num_filter_struct_args}= Get Length ${filter_struct_args} Return From Keyword If '${num_filter_struct_args}' == '${0}' &{packed_dict} ${filtered_error_logs}= Filter Struct ${packed_dict} &{filter_struct_args} [Return] ${filtered_error_logs} Get Event Logs Not Ok [Documentation] Get all event logs where the 'Severity' is not 'OK'. ${members}= Get Event Logs ${severe_logs}= Evaluate [elog for elog in $members if elog['Severity'] != 'OK'] [Return] ${severe_logs} Get Number Of Event Logs [Documentation] Return the number of EventLog members. ${members}= Get Event Logs ${num_members}= Get Length ${members} [Return] ${num_members} Redfish Purge Event Log [Documentation] Do Redfish EventLog purge. ${target_action}= redfish_utils.Get Target Actions ... /redfish/v1/Systems/system/LogServices/EventLog/ LogService.ClearLog Redfish.Post ${target_action} body={'target': '${target_action}'} ... valid_status_codes=[${HTTP_OK}, ${HTTP_NO_CONTENT}] Event Log Should Not Exist [Documentation] Event log entries should not exist. ${elogs}= Get Event Logs Should Be Empty ${elogs} msg=System event log entry is not empty. Redfish Clear PostCodes [Documentation] Do Redfish PostCodes purge from system. ${target_action}= redfish_utils.Get Target Actions ... /redfish/v1/Systems/system/LogServices/PostCodes/ LogService.ClearLog Redfish.Post ${target_action} body={'target': '${target_action}'} ... valid_status_codes=[${HTTP_OK}, ${HTTP_NO_CONTENT}] Redfish Get PostCodes [Documentation] Perform Redfish GET request and return the PostCodes entries as a list of dictionaries. # Formatted example output from Rprint vars members # members: # [0]: # [@odata.id]: /redfish/v1/Systems/system/LogServices/PostCodes/Entries/B1-1 # [@odata.type]: #LogEntry.v1_8_0.LogEntry # [AdditionalDataURI]: /redfish/v1/Systems/system/LogServices/PostCodes/Entries/B1-1/attachment # [Created]: 2022-08-06T04:38:10+00:00 # [EntryType]: Event # [Id]: B1-1 # [Message]: Message": "Boot Count: 4: TS Offset: 0.0033; POST Code: 0x43 # [MessageArgs]: # [0]: 4 # [1]: 0.0033 # [2]: 0x43 # [MessageId]: OpenBMC.0.2.BIOSPOSTCodeASCII # [Name]: POST Code Log Entry # [Severity]: OK ${members}= Redfish.Get Attribute /redfish/v1/Systems/system/LogServices/PostCodes/Entries Members ... valid_status_codes=[${HTTP_OK}, ${HTTP_NO_CONTENT}] [Return] ${members}