*** Settings *** Documentation Utilities for fan tests. Library ../lib/bmc_ssh_utils.py Resource ../lib/openbmc_ffdc_utils.robot Variables ../data/variables.py *** Keywords *** Is Water Cooled [Documentation] Return 1 if system is water cooled, 0 othersise. ${water_cooled}= Read Attribute ... ${HOST_INVENTORY_URI}/system/chassis WaterCooled [Return] ${water_cooled} Get Fan Names [Documentation] Get the names of fans marked present in inventory. [Arguments] ${fan_names} # This keyword populates the fan_names list with the names of # fans present in inventory e.g. fan0, fan2, fan3. # Description of Argument(s): # fan_names The list of fan names to which new fan names are to be # added to. This list is returned to the caller. ${fan_uris}= Get Endpoint Paths ${HOST_INVENTORY_URI}/system fan : FOR ${fan_uri} IN @{fan_uris} \ ${fan_properties}= Read Properties ${fan_uri} \ Continue For Loop If ${fan_properties['Present']} != 1 \ ${remaining_uri} ${fan_name}= Split Path ${fan_uri} \ Append To List ${fan_names} ${fan_name} [Return] ${fan_names} Verify System Error Indication Due To Fans [Documentation] Verify enclosure LEDs are on and there's an error log. # Both enclosure LEDs should now be On. Verify Front And Rear LED State On # An error log should now exist. Error Logs Should Exist Verify Front And Rear LED State [Documentation] Check state of the front and rear enclsure fault LEDs. [Arguments] ${state} # Both LEDs should be in the specified state. If not fail the test case. # Description of Argument(s): # state The state to check for, either 'Off' or 'On'. ${front_fault}= Get System LED State front_fault ${rear_fault}= Get System LED State rear_fault Run Keyword If ... '${front_fault}' != '${state}' or '${rear_fault}' != '${state}' ... Fail msg=Expecting both enclosure LEDs to be ${state}. Set Fan State [Documentation] Set the fan state, either functional or non-functional. [Arguments] ${fan_name} ${fan_state} # Description of Argument(s): # fan_name The name of the fan, e.g. "fan2". # fan_state The state to set, 1 for functional, 2 for non-functional. ${valueDict}= Create Dictionary data=${fan_state} Write Attribute ... ${HOST_INVENTORY_URI}system/chassis/motherboard/${fan_name} ... Functional data=${valueDict} Get Target Speed Of Fans [Documentation] Return the maximum target RPM speed of the system fans. ${max_target}= Set Variable 0 ${paths}= Get Endpoint Paths ${SENSORS_URI}fan_tach/ 0 :FOR ${path} IN @{paths} \ ${response}= OpenBMC Get Request ${path} \ ${json}= To JSON ${response.content} \ ${target_speed}= Set Variable ${json["data"]["Target"]} \ ${max_target}= Run Keyword If ${target_speed} > ${max_target} ... Set Variable ${target_speed} ELSE Set Variable ${max_target} [Return] ${max_target} Verify Minimum Number Of Fans With Cooling Type [Documentation] Verify minimum number of fans. [Arguments] ${num_fans} ${water_cooled} # Description of argument(s): # num_fans The number of fans present in the system. # water_cooled The value 1 if the system is water cooled, # 0 if air cooled. # For a water cooled system. ${min_fans_water}= Set Variable 2 # For an air cooled system. ${min_fans_air}= Set Variable 3 Rprintn Rpvars num_fans water_cooled # If water cooled must have at least min_fans_water fans, otherwise # issue Fatal Error and terminate testing. Run Keyword If ${water_cooled} == 1 and ${num_fans} < ${min_fans_water} ... Fatal Error ... msg=Water cooled but less than ${min_fans_water} fans present. # If air cooled must have at least min_fans_air fans. Run Keyword If ${water_cooled} == 0 and ${num_fans} < ${min_fans_air} ... Fatal Error ... msg=Air cooled but less than ${min_fans_air} fans present. Verify Fan Monitors With State [Documentation] Verify fan monitor daemons in the system state. [Arguments] ${power_state} # The number of monitoring daemons is dependent upon the system # power state. If power is off there should be 0, if power # is on there should be several. # Description of argument(s): # power_state Power staet of the system, either "On" or "Off" ${cmd}= Catenate systemctl list-units | grep phosphor-fan | wc -l ${num_fan_daemons} ${stderr} ${rc}= BMC Execute Command ${cmd} Rpvars power_state num_fan_daemons # Fail if system is On and there are no fan monitors. Run Keyword If '${power_state}' == 'On' and ${num_fan_daemons} == 0 ... Fail msg=No phosphor-fan monitors found at power on. # Fail if system is Off and the fan monitors are present. Run Keyword If '${power_state}' == 'Off' and ${num_fan_daemons} != 0 ... Fail msg=Phosphor-fan monitors found at power off.