*** Settings *** Documentation Update the PNOR code on a target BMC. ... Execution Method: ... python -m robot -v OPENBMC_HOST: ... -v DELETE_OLD_PNOR_IMAGES:<"true" or "false"> ... -v IMAGE_FILE_PATH: ... -v ALTERNATE_IMAGE_FILE_PATH: ... host_code_update.robot ... ... Code update method BMC ... Update work flow sequence: ... - Upload image via REST ... - Verify that the file exists on the BMC ... - Check that software "Activation" is set to "Ready" ... - Set "Requested Activation" to "Active" ... - Wait for code update to complete ... - Verify the new version Library ../../lib/bmc_ssh_utils.py Library ../../lib/code_update_utils.py Library ../../lib/gen_robot_keyword.py Variables ../../data/variables.py Resource ../../lib/boot_utils.robot Resource code_update_utils.robot Resource ../../lib/code_update_utils.robot Resource ../../lib/openbmc_ffdc.robot Resource ../../lib/state_manager.robot Resource ../../lib/dump_utils.robot Test Teardown Code Update Test Teardown Force Tags Host_Code_Update *** Variables *** ${QUIET} ${1} ${IMAGE_FILE_PATH} ${EMPTY} ${DELETE_OLD_PNOR_IMAGES} false ${DELETE_OLD_GUARD_FILE} false ${ALTERNATE_IMAGE_FILE_PATH} ${EMPTY} ${SKIP_UPDATE_IF_ACTIVE} false ${cache_files_dir_path} /var/lib/phosphor-software-manager/pnor/prsv/ *** Test Cases *** REST Host Code Update [Documentation] Do a PNOR code update by uploading image on BMC via REST. # 1. Delete error logs if there is any. # 1. Do code update. # 2. Do post update the following: # - Collect FFDC if error log exist and delete error logs. [Tags] REST_Host_Code_Update [Setup] Code Update Setup Run Keyword And Ignore Error List Installed Images Host Upload And Activate Image ${IMAGE_FILE_PATH} ... skip_if_active=${SKIP_UPDATE_IF_ACTIVE} OBMC Reboot (off) Post Update Boot To OS [Documentation] Boot the host OS [Tags] Post_Update_Boot_To_OS [Setup] Start SOL Console Logging [Teardown] Run Keywords Stop SOL Console Logging ... AND Code Update Test Teardown Run Keyword If '${PREV_TEST_STATUS}' == 'FAIL' ... Fail Code update failed. No need to boot to OS. Delete All Error Logs REST Power On Verify Running Host Image ${IMAGE_FILE_PATH} Test Boot With No VPD Cache [Documentation] After having done a PNOR update and ... booted the OS in the tests above, remove the cached ... VPD files and verify that the OS can still boot. [Tags] Test_Boot_With_No_VPD_Cache [Setup] Start SOL Console Logging [Teardown] Run Keywords Stop SOL Console Logging ... AND Code Update Test Teardown ${num_vpd_files} ${stderr} ${rc}= BMC Execute Command ... ls ${cache_files_dir_path} | grep VPD -c # Typically, vpd files = "CVPD DJVPD MVPD NVRAM". Should Be Equal As Integers ${num_vpd_files} ${3} ... msg=Missing VPD files at ${cache_files_dir_path}. # Delete the *VPD* files. BMC Execute Command rm -f ${xxx_dir_path}*VPD* REST Power On # After powering-on the system, the VPD files should be present. ${num_vpd_files} ${stderr} ${rc}= BMC Execute Command ... ls ${cache_files_dir_path} | grep VPD -c Should Be Equal As Integers ${num_vpd_files} ${3} ... msg=Three VPD files expected at ${cache_files_dir_path}. # Power off. The next test case will boot the OS with the new VPD files. REST Power Off REST Host Code Update While OS Is Running [Documentation] Do a PNOR code update while the host is running. [Tags] REST_Host_Code_Update_While_OS_Is_Running [Teardown] Run Keywords REST Power Off stack_mode=skip ... AND Code Update Test Teardown Run Keyword If '${PREV_TEST_STATUS}' == 'FAIL' ... Fail Cannot boot the OS. REST Power On stack_mode=skip Upload And Activate Image ... ${ALTERNATE_IMAGE_FILE_PATH} skip_if_active=true REST Power On stack_mode=normal Verify Running Host Image ${ALTERNATE_IMAGE_FILE_PATH} Host Image Priority Attribute Test [Documentation] Set "Priority" attribute. [Tags] Host_Image_Priority_Attribute_Test [Template] Temporarily Set PNOR Attribute # Property Value Priority ${0} Priority ${1} Priority ${127} Priority ${255} Host Set Priority To Invalid Values [Documentation] Attempt to set the priority of an image to an invalid ... value and expect an error. [Tags] Host_Set_Priority_To_Invalid_Values [Template] Set Priority To Invalid Value And Expect Error # Version Type Priority ${VERSION_PURPOSE_HOST} ${-1} ${VERSION_PURPOSE_HOST} ${256} Set RequestedActivation To None [Documentation] Set the RequestedActivation of the image to None and ... verify that it is in fact set to None. [Tags] Set_RequestedActivation_To_None ${software_objects}= Get Software Objects Set Host Software Property @{software_objects}[0] RequestedActivation ... ${REQUESTED_NONE} ${software_properties}= Get Host Software Property @{software_objects}[0] Should Be Equal As Strings &{software_properties}[RequestedActivation] ... ${REQUESTED_NONE} Set RequestedActivation And Activation To Invalid Value [Documentation] Set the RequestedActivation and Activation propreties of ... the image to an invalid value and verify that it was not ... changed. [Template] Set Property To Invalid Value And Verify No Change [Tags] Set_RequestedActivation_And_Activation_To_Invalid_Value # Property Version Type RequestedActivation ${VERSION_PURPOSE_HOST} Activation ${VERSION_PURPOSE_HOST} Upload And Activate Multiple Host Images [Documentation] Upload another PNOR image and verify that its state is ... different from all others. [Tags] Upload_And_Activate_Multiple_Host_Images [Template] Activate Image And Verify No Duplicate Priorities [Setup] Upload And Activate Multiple BMC Images Setup # Image File Path Image Purpose ${ALTERNATE_IMAGE_FILE_PATH} ${VERSION_PURPOSE_HOST} Set Same Priority For Multiple Host Images [Documentation] Attempt to set the priority to be the same for two PNOR ... images and verify that the priorities are not the same. [Tags] Set_Same_Priority_For_Multiple_Host_Images Run Keyword If '${PREV_TEST_STATUS}' == 'FAIL' ... Fail Activation of alternate image failed. Cannot set priority. Set Same Priority For Multiple Images ${VERSION_PURPOSE_HOST} Delete Host Image [Documentation] Delete a PNOR image from the BMC and PNOR flash chip. [Tags] Delete_Host_Image [Setup] Initiate Host PowerOff ${software_objects}= Get Software Objects ... version_type=${VERSION_PURPOSE_HOST} ${num_images}= Get Length ${software_objects} Should Be True 0 < ${num_images} ... msg=There are no PNOR images on the BMC to delete. Delete Image And Verify @{software_objects}[0] ${VERSION_PURPOSE_HOST} Verify Host Update When Host Reboot During Activation In Progress [Documentation] Attempt to reboot the host while an image is activating. [Tags] Verify_Host_Update_When_Host_Reboot_During_Activation_In_Progress Upload And Activate Image ${IMAGE_FILE_PATH} REST Power On Delete All Error Logs ${version_id}= Upload And Activate Image ${ALTERNATE_IMAGE_FILE_PATH} ... wait=${0} ${resp}= OpenBMC Get Request ${SOFTWARE_VERSION_URI}${version_id} Should Be Equal As Strings ${resp.status_code} ${HTTP_OK} # Reboot Host during activation. Host Reboot Wait For Activation State Change ${version_id} ${ACTIVATING} # New image priority should be 0. ${new_host_properties}= ... Get Host Software Property ${SOFTWARE_VERSION_URI}${version_id} Should Be Equal As Integers ${new_host_properties["Priority"]} ${0} # Reboot host to boot up with the new host image version. Host Reboot Verify Running Host Image ${ALTERNATE_IMAGE_FILE_PATH} *** Keywords *** Temporarily Set PNOR Attribute [Documentation] Update the PNOR attribute value. [Arguments] ${attribute_name} ${attribute_value} # Description of argument(s): # attribute_name Host software attribute name (e.g. "Priority"). # attribute_value Value to be written. ${image_ids}= Get Software Objects ${init_host_properties}= Get Host Software Property ${image_ids[0]} ${initial_priority}= Set Variable ${init_host_properties["Priority"]} Set Host Software Property ${image_ids[0]} ${attribute_name} ... ${attribute_value} ${cur_host_properties}= Get Host Software Property ${image_ids[0]} Should Be Equal As Integers ${cur_host_properties["Priority"]} ... ${attribute_value} # Revert to to initial value. Set Host Software Property ... ${image_ids[0]} ${attribute_name} ${initial_priority} Code Update Setup [Documentation] Do code update test case setup. # - Clean up all existing BMC dumps. # - Clean up all currently install PNOR images. Run Keyword And Ignore Error Smart Power Off Run Key Delete All Dumps ignore=1 Run Key Delete All Error Logs ignore=1 Run Keyword If 'true' == '${DELETE_OLD_PNOR_IMAGES}' ... Delete All PNOR Images Run Keyword If 'true' == '${DELETE_OLD_GUARD_FILE}' BMC Execute Command ... rm -f /var/lib/phosphor-software-manager/pnor/prsv/GUARD BMC Execute Command rm -rf /tmp/images/* Upload And Activate Multiple BMC Images Setup [Documentation] Check that the ALTERNATE_FILE_PATH variable is set. Should Not Be Empty ${ALTERNATE_IMAGE_FILE_PATH} Delete All PNOR Images Upload And Activate Image ${IMAGE_FILE_PATH} skip_if_active=true Get PNOR Extended Version [Documentation] Return the PNOR extended version. [Arguments] ${manifest_path} # Description of argument(s): # manifest_path Path of the MANIFEST file # (e.g. "/tmp/images/abc123/MANIFEST"). ${version}= BMC Execute Command ... grep extended_version= ${manifest_path} [return] ${version.split(",")} Code Update Test Teardown [Documentation] Do code update test case teardown. # 1. Collect FFDC if test case failed. # 2. Collect FFDC if test PASS but error log exists. FFDC On Test Case Fail Run Keyword If '${TEST_STATUS}' == 'PASS' Check Error And Collect FFDC