import os from robot.libraries.BuiltIn import BuiltIn OPENBMC_BASE_URI = '/xyz/openbmc_project/' OPENBMC_BASE_DBUS = 'xyz.openbmc_project.' # org open power base URI. OPENPOWER_BASE_URI = '/org/open_power/' OPENPOWER_CONTROL = OPENPOWER_BASE_URI + 'control/' OPENPOWER_SENSORS = OPENPOWER_BASE_URI + 'sensors/' # REST URI base endpoint paths. CONTROL_URI = OPENBMC_BASE_URI + 'control/' # old vs new code dependencies in many places. # TODO: remove when ready. SETTINGS_URI = '/org/openbmc/settings/' WATCHDOG_URI = OPENBMC_BASE_URI + 'watchdog/' TIME_MANAGER_URI = OPENBMC_BASE_URI + 'time/' NETWORK_MANAGER = OPENBMC_BASE_URI + 'network/' NETWORK_RESOURCE = 'xyz.openbmc_project.Network.IP.Protocol.IPv4' # SNMP SNMP_MANAGER_URI = NETWORK_MANAGER + 'snmp/manager/' # Sensors base variables. SENSORS_URI = OPENBMC_BASE_URI + 'sensors/' # Thermal Control base variables THERMAL_CONTROL_URI = CONTROL_URI + 'thermal/0' # State Manager base variables BMC_REBOOT_TRANS = 'xyz.openbmc_project.State.BMC.Transition.Reboot' HOST_POWEROFF_TRANS = 'xyz.openbmc_project.State.Host.Transition.Off' HOST_POWERON_TRANS = 'xyz.openbmc_project.State.Host.Transition.On' HOST_REBOOT_TRANS = 'xyz.openbmc_project.State.Host.Transition.Reboot' HOST_POWEROFF_STATE = 'xyz.openbmc_project.State.Host.HostState.Off' HOST_POWERON_STATE = 'xyz.openbmc_project.State.Host.HostState.Running' CHASSIS_POWEROFF_TRANS = 'xyz.openbmc_project.State.Chassis.Transition.Off' CHASSIS_POWERON_TRANS = 'xyz.openbmc_project.State.Chassis.Transition.On' CHASSIS_POWEROFF_STATE = 'xyz.openbmc_project.State.Chassis.PowerState.Off' CHASSIS_POWERON_STATE = 'xyz.openbmc_project.State.Chassis.PowerState.On' # State Manager URI variables. SYSTEM_STATE_URI = OPENBMC_BASE_URI + 'state/' BMC_STATE_URI = OPENBMC_BASE_URI + 'state/bmc0/' HOST_STATE_URI = OPENBMC_BASE_URI + 'state/host0/' CHASSIS_STATE_URI = OPENBMC_BASE_URI + 'state/chassis0/' HOST_WATCHDOG_URI = OPENBMC_BASE_URI + 'watchdog/host0/' # Logging URI variables BMC_LOGGING_URI = OPENBMC_BASE_URI + 'logging/' BMC_LOGGING_ENTRY = BMC_LOGGING_URI + 'entry/' # Software manager version SOFTWARE_VERSION_URI = OPENBMC_BASE_URI + 'software/' ACTIVE = 'xyz.openbmc_project.Software.Activation.Activations.Active' READY = 'xyz.openbmc_project.Software.Activation.Activations.Ready' INVALID = 'xyz.openbmc_project.Software.Activation.Activations.Invalid' ACTIVATING = 'xyz.openbmc_project.Software.Activation.Activations.Activating' NOTREADY = 'xyz.openbmc_project.Software.Activation.Activations.NotReady' FAILED = 'xyz.openbmc_project.Software.Activation.Activations.Failed' SOFTWARE_ACTIVATION = 'xyz.openbmc_project.Software.Activation' REQUESTED_ACTIVATION = SOFTWARE_ACTIVATION + '.RequestedActivations' REQUESTED_ACTIVE = REQUESTED_ACTIVATION + '.Active' REQUESTED_NONE = REQUESTED_ACTIVATION + '.None' SOFTWARE_PURPOSE = 'xyz.openbmc_project.Software.Version.VersionPurpose' VERSION_PURPOSE_HOST = SOFTWARE_PURPOSE + '.Host' VERSION_PURPOSE_BMC = SOFTWARE_PURPOSE + '.BMC' VERSION_PURPOSE_SYSTEM = SOFTWARE_PURPOSE + '.System' # Image Upload Directory Path IMAGE_UPLOAD_DIR_PATH = '/tmp/images/' # Inventory URI variables HOST_INVENTORY_URI = OPENBMC_BASE_URI + 'inventory/' CHASSIS_INVENTORY_URI = HOST_INVENTORY_URI + 'system/chassis/' MOTHERBOARD_INVENTORY_URI = CHASSIS_INVENTORY_URI + 'motherboard/' # Led URI variable LED_GROUPS_URI = OPENBMC_BASE_URI + 'led/groups/' LED_PHYSICAL_URI = OPENBMC_BASE_URI + 'led/physical/' LED_LAMP_TEST_ASSERTED_URI = LED_GROUPS_URI + 'lamp_test/' LED_PHYSICAL_PS0_URI = LED_PHYSICAL_URI + 'cffps1_69/' LED_PHYSICAL_PS1_URI = LED_PHYSICAL_URI + 'cffps1_68/' LED_PHYSICAL_FAN0_URI = LED_PHYSICAL_URI + 'fan0/' LED_PHYSICAL_FAN2_URI = LED_PHYSICAL_URI + 'fan2/' LED_PHYSICAL_FAN3_URI = LED_PHYSICAL_URI + 'fan3/' # Host control URI variables. CONTROL_HOST_URI = OPENBMC_BASE_URI + 'control/host0/' # Power restore variables. POWER_RESTORE_URI = CONTROL_HOST_URI + 'power_restore_policy' CONTROL_DBUS_BASE = 'xyz.openbmc_project.Control.' RESTORE_LAST_STATE = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.Restore' ALWAYS_POWER_ON = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.AlwaysOn' ALWAYS_POWER_OFF = CONTROL_DBUS_BASE + 'Power.RestorePolicy.Policy.AlwaysOff' # Dump URI variables. DUMP_URI = OPENBMC_BASE_URI + 'dump/' DUMP_ENTRY_URI = DUMP_URI + 'entry/' DUMP_DOWNLOAD_URI = "/download/dump/" # The path on the BMC where dumps are stored. DUMP_DIR_PATH = "/var/lib/phosphor-debug-collector/dumps/" # Boot progress variables. STATE_DBUS_BASE = 'xyz.openbmc_project.State.' OS_BOOT_START = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.OSStart' OS_BOOT_OFF = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.Unspecified' OS_BOOT_PCI = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.PCIInit' OS_BOOT_SECPCI = STATE_DBUS_BASE + \ 'Boot.Progress.ProgressStages.SecondaryProcInit' OS_BOOT_MEM = STATE_DBUS_BASE + 'Boot.Progress.ProgressStages.MemoryInit' OS_BOOT_MOTHERBOARD = STATE_DBUS_BASE + \ 'Boot.Progress.ProgressStages.MotherboardInit' # OperatingSystem status variables. OS_BOOT_COMPLETE = STATE_DBUS_BASE + \ 'OperatingSystem.Status.OSStatus.BootComplete' OS_BOOT_CDROM = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.CDROMBoot' OS_BOOT_ROM = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.ROMBoot' OS_BOOT_PXE = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.PXEBoot' OS_BOOT_CBoot = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.CBoot' OS_BOOT_DiagBoot = STATE_DBUS_BASE + 'OperatingSystem.Status.OSStatus.DiagBoot' # Boot variables. BOOT_SOURCE_DEFAULT = 'xyz.openbmc_project.Control.Boot.Source.Sources.Default' BOOT_SOURCE_NETWORK = 'xyz.openbmc_project.Control.Boot.Source.Sources.Network' BOOT_SOURCE_DISK = 'xyz.openbmc_project.Control.Boot.Source.Sources.Disk' BOOT_SOURCE_CDROM = 'xyz.openbmc_project.Control.Boot.Source.Sources.ExternalMedia' BOOT_MODE_SAFE = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Safe' BOOT_MODE_SETUP = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Setup' BOOT_MODE_REGULAR = 'xyz.openbmc_project.Control.Boot.Mode.Modes.Regular' # Time variables. TIME_DBUS_BASE = 'xyz.openbmc_project.Time.' BMC_OWNER = TIME_DBUS_BASE + 'Owner.Owners.BMC' HOST_OWNER = TIME_DBUS_BASE + 'Owner.Owners.Host' SPLIT_OWNER = TIME_DBUS_BASE + 'Owner.Owners.Split' BOTH_OWNER = TIME_DBUS_BASE + 'Owner.Owners.Both' NTP_MODE = TIME_DBUS_BASE + 'Synchronization.Method.NTP' MANUAL_MODE = TIME_DBUS_BASE + 'Synchronization.Method.Manual' # User manager variable. BMC_USER_URI = OPENBMC_BASE_URI + 'user/' # LDAP User manager variable. BMC_LDAP_URI = BMC_USER_URI + 'ldap' # The path on the BMC where signed keys are stored. ACTIVATION_DIR_PATH = "/etc/activationdata/" # Redfish variables. REDFISH_BASE_URI = '/redfish/v1/' REDFISH_SESSION = REDFISH_BASE_URI + 'SessionService/Sessions' REDFISH_SESSION_URI = 'SessionService/Sessions/' REDFISH_NW_ETH0 = 'Managers/bmc/EthernetInterfaces/eth0/' REDFISH_NW_ETH0_URI = REDFISH_BASE_URI + REDFISH_NW_ETH0 REDFISH_NW_ETH_IFACE = REDFISH_BASE_URI + 'Managers/bmc/EthernetInterfaces/' REDFISH_NW_PROTOCOL = 'Managers/bmc/NetworkProtocol' REDFISH_NW_PROTOCOL_URI = REDFISH_BASE_URI + REDFISH_NW_PROTOCOL REDFISH_ACCOUNTS_SERVICE = 'AccountService/' REDFISH_ACCOUNTS_SERVICE_URI = REDFISH_BASE_URI + REDFISH_ACCOUNTS_SERVICE REDFISH_ACCOUNTS = 'AccountService/Accounts/' REDFISH_ACCOUNTS_URI = REDFISH_BASE_URI + REDFISH_ACCOUNTS REDFISH_HTTPS_CERTIFICATE = 'Managers/bmc/NetworkProtocol/HTTPS/Certificates' REDFISH_HTTPS_CERTIFICATE_URI = REDFISH_BASE_URI + REDFISH_HTTPS_CERTIFICATE REDFISH_LDAP_CERTIFICATE = 'AccountService/LDAP/Certificates' REDFISH_LDAP_CERTIFICATE_URI = REDFISH_BASE_URI + REDFISH_LDAP_CERTIFICATE REDFISH_CA_CERTIFICATE = 'Managers/bmc/Truststore/Certificates' REDFISH_CA_CERTIFICATE_URI = REDFISH_BASE_URI + REDFISH_CA_CERTIFICATE REDFISH_CHASSIS_URI = REDFISH_BASE_URI + 'Chassis/' REDFISH_CHASSIS_THERMAL = 'chassis/Thermal/' REDFISH_CHASSIS_THERMAL_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_THERMAL REDFISH_CHASSIS_POWER = 'chassis/Power/' REDFISH_CHASSIS_POWER_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_POWER REDFISH_CHASSIS_SENSORS = 'chassis/Sensors' REDFISH_CHASSIS_SENSORS_URI = REDFISH_CHASSIS_URI + REDFISH_CHASSIS_SENSORS # Boot options and URI variables. POWER_ON = 'On' POWER_GRACEFUL_OFF = "GracefulShutdown" POWER_GRACEFUL_RESTART = "GracefulRestart" POWER_FORCE_OFF = 'ForceOff' REDFISH_POWER = 'Systems/system/Actions/ComputerSystem.Reset' REDFISH_POWER_URI = REDFISH_BASE_URI + REDFISH_POWER # rsyslog variables. REMOTE_LOGGING_URI = OPENBMC_BASE_URI + 'logging/config/remote/' # Certificate variables. SERVER_CERTIFICATE_URI = OPENBMC_BASE_URI + 'certs/server/https' CLIENT_CERTIFICATE_URI = OPENBMC_BASE_URI + 'certs/client/ldap' CA_CERTIFICATE_URI = OPENBMC_BASE_URI + 'certs/authority/ldap' # EventLog variables. SYSTEM_BASE_URI = REDFISH_BASE_URI + 'Systems/system/' EVENT_LOG_URI = SYSTEM_BASE_URI + 'LogServices/EventLog/' ''' QEMU HTTPS variable: By default lib/resource.robot AUTH URI construct is as ${AUTH_URI} https://${OPENBMC_HOST}${AUTH_SUFFIX} ${AUTH_SUFFIX} is populated here by default EMPTY else the port from the OS environment ''' AUTH_SUFFIX = ":" + BuiltIn().get_variable_value("${HTTPS_PORT}", os.getenv('HTTPS_PORT', '443')) # Here contains a list of valid Properties bases on fru_type after a boot. INVENTORY_ITEMS = { "CPU": [ "Custom Field 1", "Custom Field 2", "Custom Field 3", "Custom Field 4", "Custom Field 5", "Custom Field 6", "Custom Field 7", "Custom Field 8", "FRU File ID", "Manufacturer", "Name", "Part Number", "Serial Number", "fault", "fru_type", "is_fru", "present", "version", ], "DIMM": [ "Asset Tag", "Custom Field 1", "Custom Field 2", "Custom Field 3", "Custom Field 4", "Custom Field 5", "Custom Field 6", "Custom Field 7", "Custom Field 8", "FRU File ID", "Manufacturer", "Model Number", "Name", "Serial Number", "Version", "fault", "fru_type", "is_fru", "present", "version", ], "MEMORY_BUFFER": [ "Custom Field 1", "Custom Field 2", "Custom Field 3", "Custom Field 4", "Custom Field 5", "Custom Field 6", "Custom Field 7", "Custom Field 8", "FRU File ID", "Manufacturer", "Name", "Part Number", "Serial Number", "fault", "fru_type", "is_fru", "present", "version", ], "FAN": [ "fault", "fru_type", "is_fru", "present", "version", ], "DAUGHTER_CARD": [ "Custom Field 1", "Custom Field 2", "Custom Field 3", "Custom Field 4", "Custom Field 5", "Custom Field 6", "Custom Field 7", "Custom Field 8", "FRU File ID", "Manufacturer", "Name", "Part Number", "Serial Number", "fault", "fru_type", "is_fru", "present", "version", ], "BMC": [ "fault", "fru_type", "is_fru", "manufacturer", "present", "version", ], "MAIN_PLANAR": [ "Custom Field 1", "Custom Field 2", "Custom Field 3", "Custom Field 4", "Custom Field 5", "Custom Field 6", "Custom Field 7", "Custom Field 8", "Part Number", "Serial Number", "Type", "fault", "fru_type", "is_fru", "present", "version", ], "SYSTEM": [ "Custom Field 1", "Custom Field 2", "Custom Field 3", "Custom Field 4", "Custom Field 5", "Custom Field 6", "Custom Field 7", "Custom Field 8", "FRU File ID", "Manufacturer", "Model Number", "Name", "Serial Number", "Version", "fault", "fru_type", "is_fru", "present", "version", ], "CORE": [ "fault", "fru_type", "is_fru", "present", "version", ], }