# Monitoring and Logging OpenBMC Systemd Target and Service Failures Author: Andrew Geissler < geissonator > Created: June 18, 2019 Last Updated: Feb 21, 2022 ## Problem Description OpenBMC uses systemd to coordinate the starting and stopping of its applications. For example, systemd is used to start all of OpenBMC's initial services, to power on and off the servers it manages, and to perform operations like firmware updates. [openbmc-systemd.md][1] has a good summary of systemd and the basics of how it is used within OpenBMC. At a high level, systemd is composed of units. For OpenBMC, the two key unit types are target and service. There are situations where OpenBMC systemd targets fail. They fail due to a target or service within them hitting some sort of error condition. In some cases, the unit which caused the failure will log an error to phosphor-logging but in some situations (segfault, unhandled exception, unhandled error path, ...), there will be no indication to the end user that something failed. It is critical that if a systemd target fails within OpenBMC, the user be notified. There are also scenarios where a system has successfully started all targets but a running service within that target fails. Some services are not all that critical, but something like fan-control or a power monitoring service, could be very critical. At a minimum, need to ensure the user of the system is informed that a critical service has failed. The solution proposed in this document does not preclude service owners from doing other recovery, this solution just ensures a bare minimum of reporting is done when a failure occurs. ## Background and References See the [phosphor-state-manager][2] repository for background information on state management and systemd within OpenBMC. systemd provides signals when units complete and provides status on that completed unit. See the JobNew()/JobRemoved() section in the [systemd dbus API][3]. The six different results are: ``` done, canceled, timeout, failed, dependency, skipped ``` phosphor-state-manager code already monitors for these signals but only looks for a status of `done` to know when to mark the corresponding dbus object as ready(bmc)/on(chassis)/running(host). The proposal within this document is to monitor for these other results and log an appropriate error to phosphor-logging. A systemd unit that is a service will only enter into a `failed` state after all systemd defined retries have been executed. For OpenBMC systems, that involves 2 restarts within a 30 second window. ## Requirements ### Systemd Target Units - Must be able to monitor any arbitrary systemd target and log a defined error based on the type of failure the target encountered - Must be configurable - Target: Choose any systemd target - Status: Choose one or more status's to monitor for - Error to log: Specify error to log when error is detected - Must be able to take multiple configure files as input on startup - Support a `default` for errors to monitor for - This will be `timeout`,`failed`, and `dependency` - Error will always be the configured one with additional data indicating the status that failed (i.e. canceled, timeout, ...) - Example: ``` xyz.openbmc_project.State.BMC.Error.MultiUserTargetFailure STATUS=timeout ``` - By default, enable this monitor and logging service for all critical OpenBMC targets - Critical systemd targets are ones used by phosphor-state-manager - BMC: multi-user.target - Chassis: obmc-chassis-poweron@0.target, obmc-chassis-poweroff@0.target - Host: obmc-host-start@0.target, obmc-host-startmin@0.target, obmc-host-shutdown@0.target, obmc-host-stop@0.target, obmc-host-reboot@0.target - The errors for these must be defined in phosphor-dbus-interfaces - Limitations: - Fully qualified target name must be input (i.e. no templated / wild card target support) ### Systemd Service Units - Must be able to monitor any arbitrary systemd service within OpenBMC - Service(s) to monitor must be configurable - Log an error indicating a service has failed (with service name in log) - `xyz.openbmc_project.State.Error.CriticalServiceFailure` - Collect a BMC dump - Changes BMC state (CurrentBMCState) to indicate a degraded mode of the BMC - Report changed state externally via Redfish managers/bmc state ## Proposed Design Create a new standalone application in phosphor-state-manager which will load json file(s) on startup. The json file(s) would have the following format for targets: ``` { "targets" : [ { "name": "multi-user.target", "errorsToMonitor": ["default"], "errorToLog": "xyz.openbmc_project.State.BMC.Error.MultiUserTargetFailure", }, { "name": "obmc-chassis-poweron@0.target", "errorsToMonitor": ["timeout", "failed"], "errorToLog": "xyz.openbmc_project.State.Chassis.Error.PowerOnTargetFailure", } ] } ``` The json (files) would have the following format for services: ``` { "services" : [ "xyz.openbmc_project.biosconfig_manager.service", "xyz.openbmc_project.Dump.Manager.service" ] } ``` On startup, all input json files will be loaded and monitoring will be setup. This application will not register any interfaces on D-Bus but will subscribe to systemd dbus signals for JobRemoved. sdeventplus will be used for all D-Bus communication. For additional debug, the errors may be registered with the BMC Dump function to ensure the cause of the failure can be determined. This requires the errors logged by this service be put into `phosphor-debug-errors/errors_watch.yaml`. For service failures, a dump will be collected by default because the BMC will be moved into a Quisced state. Note that services which are short running applications responsible for transitioning the system from one target to another (i.e. chassis power on/off, starting/stopping the host, ...) are critical services, but they are not the type of services to be monitored. Their failures will cause systemd targets to fail which will fall into the target monitoring piece of this design. The service monitoring is meant for long running services which stay running after a target has completed. ## Alternatives Considered Units have an OnError directive. Could put the error logging logic within that path but it introduces more complexity to OpenBMC systemd usage which is already quite complicated. Could implement this within the existing state manager applications since they are already monitoring some of these units. The standalone application and generic capability to monitor any unit was chosen as a better option. ## Impacts A phosphor-logging event will be logged when one of the units listed above fails. This will be viewable by owners of the system. There may be situations where two logs are generated for the same issue. For example, if the power application detects an issue during power on and logs it to phosphor-logging and then returns non zero to systemd, the target that service is a part of will also fail and the code logic defined in this design will also log an error. The thought is that two errors are better than none. Also, there is a plugin architecture being defined for phosphor-logging. The user could monitor for that first error within the phosphor-logging plugin architecture and as a defined action, cancel the systemd target. A target status of `canceled` will not result in phosphor-state-manager generating an error. ## Testing Need to cause all units mentioned within this design to fail. They should fail for each of the reasons defined within this design and the error generated for each scenario should be verified. [1]: https://github.com/openbmc/docs/blob/master/architecture/openbmc-systemd.md [2]: https://github.com/openbmc/phosphor-state-manager [3]: https://www.freedesktop.org/wiki/Software/systemd/dbus/