/* // Copyright (c) 2019 Intel Corporation // // Licensed under the Apache License, Version 2.0 (the "License"); // you may not use this file except in compliance with the License. // You may obtain a copy of the License at // // http://www.apache.org/licenses/LICENSE-2.0 // // Unless required by applicable law or agreed to in writing, software // distributed under the License is distributed on an "AS IS" BASIS, // WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. // See the License for the specific language governing permissions and // limitations under the License. */ #pragma once #include namespace redfish::message_registries::openbmc { const Header header = { .copyright = "Copyright 2018 OpenBMC. All rights reserved.", .type = "#MessageRegistry.v1_0_0.MessageRegistry", .id = "OpenBMC.0.1.0", .name = "OpenBMC Message Registry", .language = "en", .description = "This registry defines the base messages for OpenBMC.", .registryPrefix = "OpenBMC", .registryVersion = "0.1.0", .owningEntity = "OpenBMC", }; const std::array registry = { MessageEntry{ "ADDDCCorrectable", { .description = "Indicates an ADDDC Correctable Error.", .message = "ADDDC Correctable Error.Socket=%1 Channel=%2 DIMM=%3 Rank=%4.", .severity = "Warning", .numberOfArgs = 4, .paramTypes = { "number", "string", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "BIOSBoot", { .description = "Indicates BIOS has transitioned control to the OS Loader.", .message = "BIOS System Boot.", .severity = "OK", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "BIOSPOSTError", { .description = "Indicates BIOS POST has encountered an error.", .message = "BIOS POST Error. Error Code=%1", .severity = "Warning", .numberOfArgs = 1, .paramTypes = {"number"}, .resolution = "None.", }}, MessageEntry{"BIOSRecoveryComplete", { .description = "Indicates BIOS Recovery has completed.", .message = "BIOS Recovery Complete.", .severity = "OK", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{"BIOSRecoveryStart", { .description = "Indicates BIOS Recovery has started.", .message = "BIOS Recovery Start.", .severity = "Warning", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{"CPUError", { .description = "Indicates that a CPU Error occurred of " "the specified type or cause.", .message = "CPU Error Occurred: %1.", .severity = "Critical", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "DCPowerOff", { .description = "Indicates that the system DC power is off.", .message = "Host system DC power is off", .severity = "OK", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{"DCPowerOn", { .description = "Indicates that the system DC power is on.", .message = "Host system DC power is on", .severity = "OK", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "EventLogCleared", { .description = "Indicates that the event log has been cleared.", .message = "Event Log Cleared.", .severity = "OK", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "FanInserted", { .description = "Indicates that a system fan has been inserted.", .message = "%1 inserted.", .severity = "OK", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{"FanRedundancyLost", { .description = "Indicates that system fan redundancy has been lost.", .message = "Fan redundancy lost.", .severity = "Warning", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "FanRedundancyRegained", { .description = "Indicates that system fan redundancy has been regained.", .message = "Fan redundancy regained.", .severity = "OK", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "FanRemoved", { .description = "Indicates that a system fan has been removed.", .message = "%1 removed.", .severity = "OK", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "FirmwareUpdateCompleted", { .description = "Indicates a firmware update has completed successfully.", .message = "%1 firmware update to version %2 completed " "successfully.", .severity = "OK", .numberOfArgs = 2, .paramTypes = {"string", "string"}, .resolution = "None.", }}, MessageEntry{"FirmwareUpdateFailed", { .description = "Indicates a firmware update has failed.", .message = "%1 firmware update to version %2 failed.", .severity = "Warning", .numberOfArgs = 2, .paramTypes = {"string", "string"}, .resolution = "None.", }}, MessageEntry{"FirmwareUpdateStarted", { .description = "Indicates a firmware update has started.", .message = "%1 firmware update to version %2 started.", .severity = "OK", .numberOfArgs = 2, .paramTypes = {"string", "string"}, .resolution = "None.", }}, MessageEntry{ "GeneralFirmwareSecurityViolation", { .description = "Indicates a general firmware security violation has occurred.", .message = "Firmware security violation: %1.", .severity = "Critical", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "InvalidLoginAttempted", { .description = "Indicates that a login was attempted on the specified " "interface with an invalid username or password.", .message = "Invalid username or password attempted on %1.", .severity = "Warning", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "InventoryAdded", { .description = "Indicates that an inventory item with the specified model, " "type, and serial number was installed.", .message = "%1 %2 with serial number %3 was installed.", .severity = "OK", .numberOfArgs = 3, .paramTypes = { "string", "string", "string", }, .resolution = "None.", }}, MessageEntry{ "InventoryRemoved", { .description = "Indicates that an inventory item with the specified model, " "type, and serial number was removed.", .message = "%1 %2 with serial number %3 was removed.", .severity = "OK", .numberOfArgs = 3, .paramTypes = { "string", "string", "string", }, .resolution = "None.", }}, MessageEntry{ "IntelUPILinkWidthReducedToHalf", { .description = "Indicates Intel UPI link width has reduced to half width.", .message = "Intel UPI link width reduced to half. Node=%1.", .severity = "Warning", .numberOfArgs = 1, .paramTypes = { "number", }, .resolution = "None.", }}, MessageEntry{ "IntelUPILinkWidthReducedToQuarter", { .description = "Indicates Intel UPI link width has reduced to quarter width.", .message = "Intel UPI link width reduced to quarter. Node=%1.", .severity = "Warning", .numberOfArgs = 1, .paramTypes = { "number", }, .resolution = "None.", }}, MessageEntry{ "IPMIWatchdog", { .description = "Indicates that there is a host watchdog event.", .message = "Host Watchdog Event: %1", .severity = "OK", .numberOfArgs = 1, .paramTypes = { "string", }, .resolution = "None.", }}, MessageEntry{ "LegacyPCIPERR", { .description = "Indicates a Legacy PCI PERR.", .message = "Legacy PCI PERR. Bus=%1 Device=%2 Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "LegacyPCISERR", { .description = "Indicates a Legacy PCI SERR.", .message = "Legacy PCI SERR. Bus=%1 Device=%2 Function=%3.", .severity = "Critical", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{"ManufacturingModeEntered", { .description = "Indicates that Factory, Manufacturing, or " "Test mode has been entered.", .message = "Entered Manufacturing Mode.", .severity = "Warning", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{"MemoryECCCorrectable", { .description = "Indicates a Correctable Memory ECC error.", .message = "Memory ECC correctable error. Socket=%1 " "Channel=%2 DIMM=%3 Rank=%4.", .severity = "Warning", .numberOfArgs = 4, .paramTypes = { "number", "string", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "MemoryECCUncorrectable", { .description = "Indicates an Uncorrectable Memory ECC error.", .message = "Memory ECC uncorrectable error. Socket=%1 Channel=%2 " "DIMM=%3 Rank=%4.", .severity = "Critical", .numberOfArgs = 4, .paramTypes = { "number", "string", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "MemoryParityCommandAndAddress", { .description = "Indicates a Command and Address parity error.", .message = "Command and Address parity error. Socket=%1 Channel=%2 " "DIMM=%3 ChannelValid=%4 DIMMValid=%5.", .severity = "Critical", .numberOfArgs = 5, .paramTypes = { "number", "string", "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{"MemoryParityNotKnown", { .description = "Indicates an unknown parity error.", .message = "Memory parity error. Socket=%1 Channel=%2 " "DIMM=%3 ChannelValid=%4 DIMMValid=%5.", .severity = "Critical", .numberOfArgs = 5, .paramTypes = { "number", "string", "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "MemoryRASConfigurationDisabled", { .description = "Indicates Memory RAS Disabled Configuration Status.", .message = "Memory RAS Configuration Disabled. Error=%1 Mode=%2.", .severity = "OK", .numberOfArgs = 2, .paramTypes = { "string", "string", }, .resolution = "None.", }}, MessageEntry{ "MemoryRASConfigurationEnabled", { .description = "Indicates Memory RAS Enabled Configuration Status.", .message = "Memory RAS Configuration Enabled. Error=%1 Mode=%2.", .severity = "OK", .numberOfArgs = 2, .paramTypes = { "string", "string", }, .resolution = "None.", }}, MessageEntry{ "MemoryRASModeDisabled", { .description = "Indicates Memory RAS Disabled Mode Selection.", .message = "Memory RAS Mode Select Disabled. Prior Mode=%1 " "Selected Mode=%2.", .severity = "OK", .numberOfArgs = 2, .paramTypes = { "string", "string", }, .resolution = "None.", }}, MessageEntry{ "MemoryRASModeEnabled", { .description = "Indicates Memory RAS Enabled Mode Selection.", .message = "Memory RAS Mode Select Enabled. Prior Mode=%1 Selected " "Mode=%2.", .severity = "OK", .numberOfArgs = 2, .paramTypes = { "string", "string", }, .resolution = "None.", }}, MessageEntry{ "MemoryThermTrip", { .description = "Indicates that the system memory ThermTrip is asserted.", .message = "Memory ThermTrip asserted.", .severity = "Critical", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "MirroringRedundancyDegraded", { .description = "Indicates the mirroring redundancy state is degraded.", .message = "Mirroring redundancy state degraded. Socket=%1 " "Channel=%2 DIMM=%3 Pair=%4 Rank=%5.", .severity = "Warning", .numberOfArgs = 5, .paramTypes = { "number", "string", "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "MirroringRedundancyFull", { .description = "Indicates the mirroring redundancy state is fully redundant.", .message = "Mirroring redundancy state fully redundant. Socket=%1 " "Channel=%2 DIMM=%3 Pair=%4 Rank=%5.", .severity = "OK", .numberOfArgs = 5, .paramTypes = { "number", "string", "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "NMIButtonPressed", { .description = "Indicates that the NMI button was pressed.", .message = "NMI Button Pressed.", .severity = "Critical", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{"NMIDiagnosticInterrupt", { .description = "Indicates that an NMI Diagnostic " "Interrupt has been generated.", .message = "NMI Diagnostic Interrupt.", .severity = "Critical", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "PCIeCorrectableAdvisoryNonFatal", { .description = "Indicates a PCIe Correctable Advisory Non-fatal Error.", .message = "PCIe Correctable Advisory Non-fatal Error. Bus=%1 " "Device=%2 Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeCorrectableBadDLLP", { .description = "Indicates a PCIe Correctable Bad DLLP Error.", .message = "PCIe Correctable Bad DLLP. Bus=%1 Device=%2 Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeCorrectableBadTLP", { .description = "Indicates a PCIe Correctable Bad TLP Error.", .message = "PCIe Correctable Bad TLP. Bus=%1 Device=%2 Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeCorrectableHeaderLogOverflow", { .description = "Indicates a PCIe Correctable Header Log Overflow Error.", .message = "PCIe Correctable Header Log Overflow. Bus=%1 Device=%2 " "Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeCorrectableInternal", { .description = "Indicates a PCIe Correctable Internal Error.", .message = "PCIe Correctable Internal Error. Bus=%1 Device=%2 " "Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{"PCIeCorrectableLinkBWChanged", { .description = "Indicates a PCIe Correctable Link BW Changed Error.", .message = "PCIe Correctable Link BW Changed. Bus=%1 " "Device=%2 Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeCorrectableReceiverError", { .description = "Indicates a PCIe Correctable Receiver Error.", .message = "PCIe Correctable Receiver Error. Bus=%1 Device=%2 " "Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeCorrectableReplayNumRollover", { .description = "Indicates a PCIe Correctable Replay Num Rollover.", .message = "PCIe Correctable Replay Num Rollover. Bus=%1 Device=%2 " "Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeCorrectableReplayTimerTimeout", { .description = "Indicates a PCIe Correctable Replay Timer Timeout.", .message = "PCIe Correctable Replay Timer Timeout. Bus=%1 " "Device=%2 Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{"PCIeCorrectableUnspecifiedAERError", { .description = "Indicates a PCIe Correctable Unspecified AER Error.", .message = "PCIe Correctable Unspecified AER Error. " "Bus=%1 Device=%2 Function=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalACSViolation", { .description = "Indicates a PCIe ACS Violation Error.", .message = "PCIe Fatal ACS Violation. Bus=%1 Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalAtomicEgressBlocked", { .description = "Indicates a PCIe Atomic Egress Blocked Error.", .message = "PCIe Fatal Atomic Egress Blocked. Bus=%1 Device=%2 " "Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalCompleterAbort", { .description = "Indicates a PCIe Completer Abort Error.", .message = "PCIe Fatal Completer Abort. Bus=%1 Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalCompletionTimeout", { .description = "Indicates a PCIe Completion Timeout Error.", .message = "PCIe Fatal Completion Timeout. Bus=%1 Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalDataLinkLayerProtocol", { .description = "Indicates a PCIe Data Link Layer Protocol Error.", .message = "PCIe Fatal Data Link Layer Protocol Error. Bus=%1 Device=%2 " "Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalECRCError", { .description = "Indicates a PCIe ECRC Error.", .message = "PCIe Fatal ECRC Error. Bus=%1 Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalFlowControlProtocol", { .description = "Indicates a PCIe Flow Control Protocol Error.", .message = "PCIe Fatal Flow Control Protocol Error. Bus=%1 Device=%2 " "Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalMalformedTLP", { .description = "Indicates a PCIe Malformed TLP Error.", .message = "PCIe Fatal Malformed TLP Error. Bus=%1 Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{"PCIeFatalMCBlockedTLP", { .description = "Indicates a PCIe MC Blocked TLP Error.", .message = "PCIe Fatal MC Blocked TLP Error. Bus=%1 " "Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalPoisonedTLP", { .description = "Indicates a PCIe Poisoned TLP Error.", .message = "PCIe Fatal Poisoned TLP Error. Bus=%1 Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalReceiverBufferOverflow", { .description = "Indicates a PCIe Receiver Buffer Overflow Error.", .message = "PCIe Fatal Receiver Buffer Overflow. Bus=%1 Device=%2 " "Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalReceivedErrNonFatalMessage", { .description = "Indicates a PCIe Received ERR_NONFATAL Message Error.", .message = "PCIe Fatal Received ERR_NONFATAL Message. Bus=%1 Device=%2 " "Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{"PCIeFatalReceivedFatalMessageFromDownstream", { .description = "Indicates a PCIe Received Fatal Message " "From Downstream Error.", .message = "PCIe Fatal Received Fatal Message From Downstream. " "Bus=%1 Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalSurpriseLinkDown", { .description = "Indicates a PCIe Surprise Link Down Error.", .message = "PCIe Fatal Surprise Link Down Error. Bus=%1 Device=%2 " "Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalTLPPrefixBlocked", { .description = "Indicates a PCIe TLP Prefix Blocked Error.", .message = "PCIe Fatal TLP Prefix Blocked Error. Bus=%1 Device=%2 " "Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalUncorrectableInternal", { .description = "Indicates a PCIe Uncorrectable Internal Error.", .message = "PCIe Fatal Uncorrectable Internal Error. Bus=%1 Device=%2 " "Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalUnexpectedCompletion", { .description = "Indicates a PCIe Unexpected Completion Error.", .message = "PCIe Fatal Unexpected Completion. Bus=%1 Device=%2 " "Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalUnspecifiedNonAERFatalError", { .description = "Indicates a PCIe Unspecified Non-AER Fatal Error.", .message = "PCIe Fatal Unspecified Non-AER Fatal Error. Bus=%1 " "Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PCIeFatalUnsupportedRequest", { .description = "Indicates a PCIe Unsupported Request Error.", .message = "PCIe Fatal Unsupported Request. Bus=%1 Device=%2 Function=%3.", .severity = "Error", .numberOfArgs = 3, .paramTypes = { "number", "number", "number", }, .resolution = "None.", }}, MessageEntry{ "PowerButtonPressed", { .description = "Indicates that the power button was pressed.", .message = "Power Button Pressed.", .severity = "OK", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{"PowerRestorePolicyApplied", { .description = "Indicates that power was restored and the " "BMC has applied the restore policy.", .message = "Power restore policy applied.", .severity = "OK", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "PowerSupplyConfigurationError", { .description = "Indicates an error in power supply configuration.", .message = "Power supply %1 configuration error.", .severity = "Critical", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "PowerSupplyFanFailed", { .description = "Indicates that the specified power supply fan has failed.", .message = "Power supply %1 fan %2 failed.", .severity = "Critical", .numberOfArgs = 2, .paramTypes = {"string", "string"}, .resolution = "None.", }}, MessageEntry{ "PowerSupplyFanRecovered", { .description = "Indicates that the power supply fan recovered from a failure.", .message = "Power supply %1 fan %2 recovered.", .severity = "OK", .numberOfArgs = 2, .paramTypes = {"string", "string"}, .resolution = "None.", }}, MessageEntry{"PowerSupplyFailed", { .description = "Indicates that a power supply has failed.", .message = "Power supply %1 failed.", .severity = "Critical", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{"PowerSupplyFailurePredicted", { .description = "Indicates that a power supply is predicted to fail.", .message = "Power supply %1 failure predicted.", .severity = "Warning", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "PowerSupplyInserted", { .description = "Indicates that a power supply has been inserted.", .message = "Power supply %1 inserted.", .severity = "OK", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "PowerSupplyPowerGoodFailed", { .description = "Indicates that the power supply power good signal " "failed to assert within the specified time.", .message = "Power supply power good failed to assert within %1 " "milliseconds.", .severity = "Critical", .numberOfArgs = 1, .paramTypes = {"number"}, .resolution = "None.", }}, MessageEntry{"PowerSupplyPowerLost", { .description = "Indicates that a power supply has lost input power.", .message = "Power supply %1 power lost.", .severity = "Critical", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "PowerSupplyPowerRestored", { .description = "Indicates that a power supply input power was restored.", .message = "Power supply %1 power restored.", .severity = "OK", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{"PowerSupplyPredictedFailureRecovered", { .description = "Indicates that a power supply recovered " "from a predicted failure.", .message = "Power supply %1 predicted failure recovered.", .severity = "OK", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "PowerSupplyRecovered", { .description = "Indicates that a power supply recovered from a failure.", .message = "Power supply %1 recovered.", .severity = "OK", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "PowerSupplyRemoved", { .description = "Indicates that a power supply has been removed.", .message = "Power supply %1 removed.", .severity = "Warning", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{ "ResetButtonPressed", { .description = "Indicates that the reset button was pressed.", .message = "Reset Button Pressed.", .severity = "OK", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{"SELEntryAdded", { .description = "Indicates a SEL entry was added using the " "Add SEL Entry or Platform Event command.", .message = "SEL Entry Added: %1", .severity = "OK", .numberOfArgs = 1, .paramTypes = { "string", }, .resolution = "None.", }}, MessageEntry{ "SensorThresholdCriticalHighGoingHigh", { .description = "Indicates that a threshold sensor has crossed a " "critical high threshold going high.", .message = "%1 sensor crossed a critical high threshold going " "high. Reading=%2 Threshold=%3.", .severity = "Critical", .numberOfArgs = 3, .paramTypes = {"string", "number", "number"}, .resolution = "Check the sensor or subsystem for errors.", }}, MessageEntry{ "SensorThresholdCriticalHighGoingLow", { .description = "Indicates that a threshold sensor has crossed a " "critical high threshold going low.", .message = "%1 sensor crossed a critical high threshold going low. " "Reading=%2 Threshold=%3.", .severity = "OK", .numberOfArgs = 3, .paramTypes = {"string", "number", "number"}, .resolution = "None.", }}, MessageEntry{ "SensorThresholdCriticalLowGoingHigh", { .description = "Indicates that a threshold sensor has crossed a " "critical low threshold going high.", .message = "%1 sensor crossed a critical low threshold going high. " "Reading=%2 Threshold=%3.", .severity = "OK", .numberOfArgs = 3, .paramTypes = {"string", "number", "number"}, .resolution = "None.", }}, MessageEntry{ "SensorThresholdCriticalLowGoingLow", { .description = "Indicates that a threshold sensor has crossed a " "critical low threshold going low.", .message = "%1 sensor crossed a critical low threshold going low. " "Reading=%2 Threshold=%3.", .severity = "Critical", .numberOfArgs = 3, .paramTypes = {"string", "number", "number"}, .resolution = "Check the sensor or subsystem for errors.", }}, MessageEntry{ "SensorThresholdWarningHighGoingHigh", { .description = "Indicates that a threshold sensor has crossed a " "warning high threshold going high.", .message = "%1 sensor crossed a warning high threshold going high. " "Reading=%2 Threshold=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = {"string", "number", "number"}, .resolution = "Check the sensor or subsystem for errors.", }}, MessageEntry{ "SensorThresholdWarningHighGoingLow", { .description = "Indicates that a threshold sensor has crossed a " "warning high threshold going low.", .message = "%1 sensor crossed a warning high threshold going low. " "Reading=%2 Threshold=%3.", .severity = "OK", .numberOfArgs = 3, .paramTypes = {"string", "number", "number"}, .resolution = "None.", }}, MessageEntry{ "SensorThresholdWarningLowGoingHigh", { .description = "Indicates that a threshold sensor has crossed a " "warning low threshold going high.", .message = "%1 sensor crossed a warning low threshold going high. " "Reading=%2 Threshold=%3.", .severity = "OK", .numberOfArgs = 3, .paramTypes = {"string", "number", "number"}, .resolution = "None.", }}, MessageEntry{ "SensorThresholdWarningLowGoingLow", { .description = "Indicates that a threshold sensor has crossed a " "warning low threshold going low.", .message = "%1 sensor crossed a warning low threshold going low. " "Reading=%2 Threshold=%3.", .severity = "Warning", .numberOfArgs = 3, .paramTypes = {"string", "number", "number"}, .resolution = "Check the sensor or subsystem for errors.", }}, MessageEntry{"ServiceFailure", { .description = "Indicates that a service has exited unsuccessfully.", .message = "Service %1 has exited unsuccessfully.", .severity = "Warning", .numberOfArgs = 1, .paramTypes = {"string"}, .resolution = "None.", }}, MessageEntry{"SparingRedundancyDegraded", { .description = "Indicates the sparing redundancy state is degraded.", .message = "Sparing redundancy state degraded. Socket=%1 " "Channel=%2 DIMM=%3 Domain=%4 Rank=%5.", .severity = "Warning", .numberOfArgs = 5, .paramTypes = { "number", "string", "number", "string", "number", }, .resolution = "None.", }}, MessageEntry{ "SparingRedundancyFull", { .description = "Indicates the sparing redundancy state is fully redundant.", .message = "Sparing redundancy state fully redundant. Socket=%1 " "Channel=%2 DIMM=%3 Domain=%4 Rank=%5.", .severity = "OK", .numberOfArgs = 5, .paramTypes = { "number", "string", "number", "string", "number", }, .resolution = "None.", }}, MessageEntry{ "SsbThermalTrip", { .description = "Indicates that an SSB Thermal trip has been asserted.", .message = "SSB Thermal trip.", .severity = "Critical", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{"SystemPowerGoodFailed", { .description = "Indicates that the system power good signal failed " "to assert within the specified time (VR failure).", .message = "System power good failed to assert within %1 " "milliseconds (VR failure).", .severity = "Critical", .numberOfArgs = 1, .paramTypes = {"number"}, .resolution = "None.", }}, MessageEntry{"SystemPowerLost", { .description = "Indicates that power was lost while the " "system was powered on.", .message = "System Power Lost.", .severity = "Critical", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "SystemPowerOffFailed", { .description = "Indicates that the system failed to power off.", .message = "System Power-Off Failed.", .severity = "Critical", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, MessageEntry{ "SystemPowerOnFailed", { .description = "Indicates that the system failed to power on.", .message = "System Power-On Failed.", .severity = "Critical", .numberOfArgs = 0, .paramTypes = {}, .resolution = "None.", }}, }; } // namespace redfish::message_registries::openbmc