Lines Matching refs:speed
178 manual mode, the fan speed is set by writing the duty-cycle value to the
198 pwm[1-3]_auto_point2_pwm full-speed duty-cycle (255, i.e., 100%)
199 pwm[1-3]_auto_point1_pwm low-speed duty-cycle
200 pwm[1-3]_auto_pwm_min min-speed duty-cycle
202 zone[1-3]_auto_point3_temp full-speed temp (all outputs)
203 zone[1-3]_auto_point2_temp full-speed temp
204 zone[1-3]_auto_point1_temp low-speed temp
205 zone[1-3]_auto_point1_temp_hyst min-speed temp
213 fan either turns completely off or keeps spinning with the low-speed
224 full-speed full-speed full-speed
230 low-speed low-speed low-speed
231 - min-speed low-speed
232 min-speed min-speed min-speed
233 - min-speed min-speed
285 the low-speed temp, auto_point2 is the
286 full-speed temp, and auto_point3 is the
288 to full-speed (100% duty-cycle).
290 fan[1-6]_input RO Measured fan speed in RPM.
339 low-speed duty-cycle.
341 full-speed duty-cycle which is hard-