13 The AP adapter cards are exposed via the AP bus. The motivation for vfio-ap
32 CPU.
45 sub-directory::
76 significant bit, correspond to domains 0-255.
111 * NQAP: to enqueue an AP command-request message to a queue
112 * DQAP: to dequeue an AP command-reply message from a queue
132 an APID from 0-255. If a bit is set, the corresponding adapter is valid for
137 corresponds to an AP queue index (APQI) from 0-255. If a bit is set, the
142 changed by an AP command-request message sent to a usage domain from the
144 0-255. If a bit is set, the corresponding domain can be modified by an AP
145 command-request message sent to a usage domain.
148 an APQN to identify the AP queue to which an AP command-request message is to be
149 sent (NQAP and PQAP instructions), or from which a command-reply message is to
156 The APQNs can provide secure key functionality - i.e., a private key is stored
157 on the adapter card for each of its domains - so each APQN must be assigned to
161 ------------------------------
170 ------------------------------
179 --------------------------------
192 3. VFIO AP mediated pass-through device
195 -------------------------
209 ---------------------------------------------
213 +------------------+
215 +--------------------> cex4queue driver |
217 | +------------------+
220 | +------------------+ +----------------+
222 | +----------------> Device core +----------> matrix device |
224 | | +--------^---------+ +----------------+
226 | | +-------------------+
227 | | +-----------------------------------+ |
230 +--------+---+-v---+ +--------+-------+-+
232 | ap_bus +--------------------- > vfio_ap driver |
234 +--------^---------+ +--^--^------------+
236 apmask | +-----------------------------+ | 11 mdev create
238 +--------+-----+---+ +----------------+-+ +----------------+
240 | admin | | VFIO device core |---------> matrix |
242 +------+-+---------+ +--------^---------+ +--------^-------+
244 | | 9 create vfio_ap-passthrough | |
245 | +------------------------------+ |
246 +-------------------------------------------------------------+
252 2. The vfio-ap driver during its initialization will register a single 'matrix'
276 ------------------------------------------
286 The following high-level block diagram shows the main components and interfaces
289 +-------------+
291 | +---------+ | mdev_register_driver() +--------------+
292 | | Mdev | +<-----------------------+ |
294 | | driver | +----------------------->+ |<-> VFIO user
295 | +---------+ | probe()/remove() +--------------+ APIs
300 | +---------+ | mdev_register_parent() +--------------+
301 | |Physical | +<-----------------------+ |
302 | | device | | | vfio_ap.ko |<-> matrix
303 | |interface| +----------------------->+ | device
304 | +---------+ | callback +--------------+
305 +-------------+
315 The VFIO mediated device framework supports creation of user-defined
320 'mdev_supported_types' sub-directory of the device being registered. Along
327 /sys/devices/vfio_ap/matrix/mdev_supported_types/vfio_ap-passthrough
329 Only the read-only attributes required by the VFIO mdev framework will
349 This attribute group identifies the user-defined sysfs attributes of the
356 Write-only attributes for assigning/unassigning an AP adapter to/from the
360 Write-only attributes for assigning/unassigning an AP usage domain to/from
365 A read-only file for displaying the APQNs derived from the Cartesian
369 A read-only file for displaying the APQNs derived from the Cartesian
376 Write-only attributes for assigning/unassigning an AP control domain
381 A read-only file for displaying the control domain numbers assigned to the
421 ----------------------------------
435 is not bound to the device driver facilitating its pass-through. Consequently,
454 The CPU model features for AP
455 -----------------------------
460 following CPU model features:
478 Note: If the user chooses to specify a CPU model different than the 'host'
479 model to QEMU, the CPU model features and facilities need to be turned on
482 /usr/bin/qemu-system-s390x ... -cpu z13,ap=on,apqci=on,apft=on,apqi=on
487 /usr/bin/qemu-system-s390x ... -cpu host,ap=off,apqci=off,apft=off,apqi=off
491 register for type 10 and newer AP devices - i.e., the cex4card and cex4queue
492 device drivers - need the APFT facility to ascertain the facilities installed on
505 ------
509 05 CEX5C CCA-Coproc
510 05.0004 CEX5C CCA-Coproc
511 05.00ab CEX5C CCA-Coproc
518 ------
522 05 CEX5C CCA-Coproc
523 05.0047 CEX5C CCA-Coproc
524 05.00ff CEX5C CCA-Coproc
528 ------
559 -> Device Drivers
560 -> IOMMU Hardware Support
562 -> VFIO Non-Privileged userspace driver framework
563 -> Mediated device driver frramework
564 -> VFIO driver for Mediated devices
565 -> I/O subsystem
566 -> VFIO support for AP devices
573 non-default device driver. The location of the sysfs files containing the
579 The 'apmask' is a 256-bit mask that identifies a set of AP adapter IDs
581 0-255. If a bit is set, the APID belongs to the subset of APQNs marked as
584 The 'aqmask' is a 256-bit mask that identifies a set of AP queue indexes
586 0-255. If a bit is set, the APQI belongs to the subset of APQNs marked as
592 All other APQNs are available to the non-default device drivers such as the
615 * All other APQNs are available for use by the non-default device drivers.
629 * An absolute hex string starting with 0x - like "0x12345678" - sets
644 number string must be prepended with a ('+') or minus ('-') to indicate
645 the corresponding bit is to be switched on ('+') or off ('-'). Some
648 - "+0" switches bit 0 on
649 - "-13" switches bit 13 off
650 - "+0x41" switches bit 65 on
651 - "-0xff" switches bit 255 off
655 +0,-6,+0x47,-0xf0
679 default drivers pool: adapter 0-15, domain 1
680 alternate drivers pool: adapter 16-255, domains 0, 2-255
685 is logged to the kernel ring buffer which can be viewed with the 'dmesg'
689 … Userspace may not re-assign queue 05.0054 already assigned to 62177883-f1bb-47f0-914d-32a22e3a8804
690 … Userspace may not re-assign queue 04.0054 already assigned to cef03c3c-903d-4ecc-9a83-40694cb8aee4
693 ----------------------------------
699 echo -5,-6 > /sys/bus/ap/apmask
701 echo -4,-0x47,-0xab,-0xff > /sys/bus/ap/aqmask
749 --- [mdev_supported_types]
750 ------ [vfio_ap-passthrough] (passthrough vfio_ap mediated device type)
751 --------- create
752 --------- [devices]
771 --- [mdev_supported_types]
772 ------ [vfio_ap-passthrough]
773 --------- [devices]
774 ------------ [$uuid1]
775 --------------- assign_adapter
776 --------------- assign_control_domain
777 --------------- assign_domain
778 --------------- matrix
779 --------------- unassign_adapter
780 --------------- unassign_control_domain
781 --------------- unassign_domain
783 ------------ [$uuid2]
784 --------------- assign_adapter
785 --------------- assign_control_domain
786 --------------- assign_domain
787 --------------- matrix
788 --------------- unassign_adapter
789 ----------------unassign_control_domain
790 ----------------unassign_domain
792 ------------ [$uuid3]
793 --------------- assign_adapter
794 --------------- assign_control_domain
795 --------------- assign_domain
796 --------------- matrix
797 --------------- unassign_adapter
798 ----------------unassign_control_domain
799 ----------------unassign_domain
854 - Must only be available to the vfio_ap device driver as specified in the
859 - Must NOT be assigned to another vfio_ap mediated device. If even one APQN
863 - Must NOT be assigned while the sysfs /sys/bus/ap/apmask and
880 - Must only be available to the vfio_ap device driver as specified in the
885 - Must NOT be assigned to another vfio_ap mediated device. If even one APQN
889 - Must NOT be assigned while the sysfs /sys/bus/ap/apmask and
902 /usr/bin/qemu-system-s390x ... -cpu host,ap=on,apqci=on,apft=on,apqi=on \
903 -device vfio-ap,sysfsdev=/sys/devices/vfio_ap/matrix/$uuid1 ...
907 /usr/bin/qemu-system-s390x ... -cpu host,ap=on,apqci=on,apft=on,apqi=on \
908 -device vfio-ap,sysfsdev=/sys/devices/vfio_ap/matrix/$uuid2 ...
912 /usr/bin/qemu-system-s390x ... -cpu host,ap=on,apqci=on,apft=on,apqi=on \
913 -device vfio-ap,sysfsdev=/sys/devices/vfio_ap/matrix/$uuid3 ...
920 --- [mdev_supported_types]
921 ------ [vfio_ap-passthrough]
922 --------- [devices]
923 ------------ [$uuid1]
924 --------------- remove
962 Over-provisioning of AP queues for a KVM guest:
964 Over-provisioning is defined herein as the assignment of adapters or domains to
967 available, it will be automatically hot-plugged into the KVM guest using
984 virsh detach-device <guestname> <path-to-device-xml>
986 For example, to hot unplug mdev 62177883-f1bb-47f0-914d-32a22e3a8804 from
987 the guest named 'my-guest':
989 virsh detach-device my-guest ~/config/my-guest-hostdev.xml
991 The contents of my-guest-hostdev.xml:
993 .. code-block:: xml
995 <hostdev mode='subsystem' type='mdev' managed='no' model='vfio-ap'>
997 <address uuid='62177883-f1bb-47f0-914d-32a22e3a8804'/>
1002 virsh qemu-monitor-command <guest-name> --hmp "device-del <device-id>"
1005 qemu command line with 'id=hostdev0' from the guest named 'my-guest':
1007 .. code-block:: sh
1009 virsh qemu-monitor-command my-guest --hmp "device_del hostdev0"
1014 (QEMU) device-del id=<device-id>
1019 (QEMU) device-del id=hostdev0
1028 virsh attach-device <guestname> <path-to-device-xml>
1030 For example, to hot plug mdev 62177883-f1bb-47f0-914d-32a22e3a8804 into
1031 the guest named 'my-guest':
1033 virsh attach-device my-guest ~/config/my-guest-hostdev.xml
1035 The contents of my-guest-hostdev.xml:
1037 .. code-block:: xml
1039 <hostdev mode='subsystem' type='mdev' managed='no' model='vfio-ap'>
1041 <address uuid='62177883-f1bb-47f0-914d-32a22e3a8804'/>
1046 virsh qemu-monitor-command <guest-name> --hmp \
1047 "device_add vfio-ap,sysfsdev=<path-to-mdev>,id=<device-id>"
1050 62177883-f1bb-47f0-914d-32a22e3a8804 into the guest named 'my-guest' with
1051 device-id hostdev0:
1053 virsh qemu-monitor-command my-guest --hmp \
1054 "device_add vfio-ap,\
1055 sysfsdev=/sys/devices/vfio_ap/matrix/62177883-f1bb-47f0-914d-32a22e3a8804,\
1061 (qemu) device_add "vfio-ap,sysfsdev=<path-to-mdev>,id=<device-id>"
1064 62177883-f1bb-47f0-914d-32a22e3a8804 into the guest with the device-id
1067 (QEMU) device-add "vfio-ap,\
1068 sysfsdev=/sys/devices/vfio_ap/matrix/62177883-f1bb-47f0-914d-32a22e3a8804,\