7 (typical -55 degC to 125 degC), if not values will be trimmed
11 master level, refer to Documentation/w1/w1-generic.rst for
37 (RO) return the power status by asking the device
41 * '-xx': xx is kernel error when reading power status
51 (RW) get or set the device resolution (on supported devices,
54 power is lost. Trigger a 'save' to EEPROM command to keep
55 values after power-on. Read or write are :
59 * '-xx': xx is kernel error when reading the resolution
62 Some DS18B20 clones are fixed in 12-bit resolution, so the
79 should retry later on.
82 conversion duration depend on the resolution (if
83 device support this feature). It takes 94ms in 9bits
84 resolution, 750ms for 12bits.
95 *read*: return 2 lines with the hexa output data sent on the
118 * '-1':
119 conversion in progress on at least 1 sensor
125 trigger a conversion on each device
128 'trigger': trigger a bulk read on all supporting
129 devices on the bus
132 immediately, the next access to temperature on this device
133 will return the temperature measured at the time of issue
143 (RW) Get, set, or measure a temperature conversion time. The
145 reset to default (datasheet) conversion time for a new
149 Actual conversion time in milliseconds.
153 Set the default conversion time from the datasheet.
155 Measure and set the conversion time. Make a single
158 conversion time can be obtained by reading this
161 Set the conversion time in milliseconds.
177 (insufficient power) - return a conversion error.
181 power mode this feature is not available.