Lines Matching +full:target +full:- +full:12 +full:v +full:- +full:supply

3 ipmitool \- utility for controlling IPMI\-enabled devices
6 ipmitool [ <options> ] <command> [ <sub-commands and sub-options> ]
8 <options> := [ <general-options> | <conditional-opts> ]
13 <general-options> := [ -h | -V | -v | -I <interface> | -H <address> |
14 -d <N> | -p <port> | -c | -U <username> |
15 -L <privlvl> | -l <lun> | -m <local_address> |
16 -N <sec> | -R <count> | <password-option> |
17 <oem-option> | <bridge-options> ]
19 <conditional-opts> := [ <lan-options> | <lanplus-options> |
20 <command-options> ]
24 <bridge-options> := -t <target_address> [ -b <channel> |
25 [ -T <address> | -B <channel> ] ]
28 Options used with -I lan:
30 <lan-options> := [ -A <authtype> ]
33 Options used with -I lanplus:
35 <lanplus-options> := [ -C <ciphersuite> | <key-option> ]
40 <key-option> := [ -k <key> | -K | -y <hex_key> | -Y ]
42 <password-option> := [ -f <password_file> | -a | -P <password> | -E ]
44 <oem-option> := [ -o <oemtype> | -g | -s ]
47 Options used with specific command <command-options>:
49 <options-sdr> := [ -S <sdr_cache_file> ]
51 <options-sel> := [ -O <sel_oem> ]
53 <options-sol> := [ -e <sol_escape_char> ]
67 Management of a remote station requires the IPMI\-over\-LAN interface to be
73 \fB\-a\fR
76 \fB\-A\fR <\fIauthtype\fP>
80 \fB\-b\fR <\fIchannel\fP>
83 \fB\-B\fR <\fIchannel\fP>
86 \fB\-b\fR <\fIchannel\fP>
89 \fB\-B\fR <\fIchannel\fP>
92 \fB\-c\fR
96 \fB\-C\fR <\fIciphersuite\fP>
98 to use for IPMIv2.0 \fIlanplus\fP connections. See table 22\-19 in the
99 IPMIv2.0 specification. The default is 3 which specifies RAKP\-HMAC\-SHA1
100 authentication, HMAC\-SHA1\-96 integrity, and AES\-CBC\-128 encryption algorithms.
102 \fB\-d \fIN\fP\fR
104 /dev/ipmi/N or /dev/ipmidev/N) device to use for in-band
105 BMC communication. Used to target a specific BMC on a
106 multi-node, multi-BMC system through the ipmi device
109 \fB\-e\fR <\fIsol_escape_char\fP>
113 \fB\-E\fR
117 \fB\-f\fR <\fIpassword_file\fP>
122 \fB\-g\fR
123 Deprecated. Use: -o intelplus
125 \fB\-h\fR
128 \fB\-H\fR <\fIaddress\fP>
132 \fB\-I\fR <\fIinterface\fP>
136 \fB\-k\fR <\fIkey\fP>
140 \fB\-K\fR
143 \fB\-l\fR <\fIlun\fP>
146 \fB\-L\fR <\fIprivlvl\fP>
150 combined with \fI-t target address\fP.
152 \fB\-m\fR <\fIlocal_address\fP>
154 or is auto discovered on PICMG platforms when -m is not specified.
157 \fB\-N\fR <\fIsec\fP>
163 \fB\-o\fR <\fIoemtype\fP>
166 various manufacturers. Use \fI\-o list\fP to see a list of
169 \fB\-O\fR <\fIsel oem\fP>
173 \fB\-p\fR <\fIport\fP>
176 \fB\-P\fR <\fIpassword\fP>
182 \fB\-R\fR <\fIcount\fP>
187 \fB\-s\fR
188 Deprecated. Use: -o supermicro
190 \fB\-S\fR <\fIsdr_cache_file\fP>
197 \fB\-t\fR <\fItarget_address\fP>
198 Bridge IPMI requests to the remote target address. Default is 32.
199 The \fI-L privlvl\fP option is always ignored and value set to ADMINISTRATOR.
201 \fB\-T\fR <\fIaddress\fP>
204 \fB\-T\fR <\fItransmit_address\fP>
207 \fB\-U\fR <\fIusername\fP>
210 \fB\-v\fR
220 \fB\-V\fR
223 \fB\-y\fR <\fIhex key\fP>
225 hexadecimal format and can be used to specify keys with non-printable
226 characters. E.g. '-k PASSWORD' and '-y 50415353574F5244' are
230 \fB\-Y\fR
233 \fB\-z\fR <\fIsize\fP>
267 This can be used to get command\-line help on ipmitool
280 ekanalyzer run FRU-Ekeying analyzer using FRU files
284 fru Print built\-in FRU and scan for FRU locators
288 i2c Send an I2C Master Write-Read command and print response
290 isol Configure and connect Intel IPMIv1.5 Serial\-over\-LAN
304 sol Configure and connect IPMIv2.0 Serial\-over\-LAN
307 tsol Configure and connect Tyan IPMIv1.5 Serial\-over\-LAN
349 Session Support : session\-less
424 0 - Off
426 force - To turn on indefinitely
441 \fIalways-on\fP
449 \fIalways-off\fP
484 Force boot from default Hard-drive.
490 Force boot from default Hard-drive, request Safe Mode.
530 Force boot from default Hard-drive
536 Force boot from default Hard-drive, request Safe Mode
676 …of an entity. Entity Instance can be in one of two ranges, system-relative or device-relative. F…
684 …of an entity. Entity Instance can be in one of two ranges, system-relative or device-relative. F…
728 Set DHCP Server contact retry interval, in seconds. The recommended default timeout is sixty-four …
744 The delloem commands provide information on Dell-specific features.
769 Allows you to set the LCD mode and user-defined string.
828 …vKVM display active or inactive and Front Panel access mode (viewandmodify, view-only or disabled).
974 \fIfilename3\fP : configuration file used for configuring On-Carrier Device ID
982 \fIoc\fP : On-Carrier device
1032 Port 1 =====> On Carrier Device ID 0, Port 12
1037 *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
1054 Display power supply informations between carrier and AMC modules.
1059 Display both physical connectivity and power supply of each carrier and AMC
1066 Convert a binary FRU file into human readable text format. Use -v option to get
1077 Display only matched results of Ekeying match between an On-Carrier device
1080 On-Carrier Device vs AMC slot B1
1081 AMC slot B1 port 0 ==> On-Carrier Device 0 port 16
1083 - From On-Carrier Device ID 0
1084 -Channel ID 11 || Lane 0: enable
1085 -Link Type: AMC.2 Ethernet
1086 -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
1087 -Link Group ID: 0 || Link Asym. Match: exact match
1088 - To AMC slot B1
1089 -Channel ID 0 || Lane 0: enable
1090 -Link Type: AMC.2 Ethernet
1091 -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
1092 -Link Group ID: 0 || Link Asym. Match: exact match
1093 *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
1094 AMC slot B1 port 1 ==> On-Carrier Device 0 port 12
1096 - From On-Carrier Device ID 0
1097 -Channel ID 6 || Lane 0: enable
1098 -Link Type: AMC.2 Ethernet
1099 -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
1100 -Link Group ID: 0 || Link Asym. Match: exact match
1101 - To AMC slot B1
1102 -Channel ID 1 || Lane 0: enable
1103 -Link Type: AMC.2 Ethernet
1104 -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
1105 -Link Group ID: 0 || Link Asym. Match: exact match
1106 *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
1107 On-Carrier Device vs AMC slot A2
1108 AMC slot A2 port 0 ==> On-Carrier Device 0 port 3
1110 - From On-Carrier Device ID 0
1111 -Channel ID 9 || Lane 0: enable
1112 -Link Type: AMC.2 Ethernet
1113 -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
1114 -Link Group ID: 0 || Link Asym. Match: exact match
1115 - To AMC slot A2
1116 -Channel ID 0 || Lane 0: enable
1117 -Link Type: AMC.2 Ethernet
1118 -Link Type extension: 1000BASE-BX (SerDES Gigabit) Ethernet link
1119 -Link Group ID: 0 || Link Asym. Match: exact match
1120 *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
1124 - From AMC slot B1
1125 -Channel ID 2 || Lane 0: enable
1126 -Link Type: AMC.3 Storage
1127 -Link Type extension: Serial Attached SCSI (SAS/SATA)
1128 -Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
1129 - To AMC slot A2
1130 -Channel ID 2 || Lane 0: enable
1131 -Link Type: AMC.3 Storage
1132 -Link Type extension: Serial Attached SCSI (SAS/SATA)
1133 -Link Group ID: 0 || Link Asym. Match: FC or SAS interface {exact match}
1134 *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
1139 Display the unmatched results of Ekeying match between an On-Carrier device
1156 Send a pre\-defined test event to the System Event Log. The following
1170 \fBNOTE\fR: These pre\-defined events will likely not produce
1190 \fIEvM Revision\fP -
1194 \fISensor Type\fP -
1197 \fISensor Num\fP -
1201 \fIEvent Dir/Type\fP -
1213 Get a list of all the possible Sensor States and pre-defined Sensor State
1221 > ipmitool \-I open event "PS 2T Fan Fault" list
1261 0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Asserted
1269 0 | Pre-Init Time-stamp | Fan PS 2T Fan Fault | State Desserted
1295 add or remove security-based restrictions on certain commands/command
1296 sub-functions or to list the current firmware firewall restrictions set on
1300 Command, and finally for a specific command's sub-function (see Appendix H in the
1301 IPMI 2.0 Specification for a listing of any sub-function numbers that may
1344 This prints out detailed, human-readable information showing the support, configurable,
1351 Print out information for a specific sub-function.
1371 where all commands and command sub-functions are enabled.
1447 <\fBstring\fR> must be the same length as the string being replaced and must be 8-bit ASCII (0xCx).
1528 Check the target information.
1533 Display both the existing target version and image version on the screen.
1560 component 0 - BOOT
1562 component 1 - RTK
1581 Get the target upgrade capabilities.
1586 Get the specified component properties. Valid component \fBid\fR: 0-7.
1589 0 - General properties
1591 1 - Current firmware version
1593 2 - Description string
1595 3 - Rollback firmware version
1597 4 - Deferred firmware version
1603 Abort the on-going firmware upgrade.
1633 Write\-Read IPMI command.
1669 Retrieve information about the Intel IPMI v1.5 Serial\-Over\-LAN
1675 Configure parameters for Intel IPMI v1.5 Serial\-over\-LAN.
1684 \fIprivilege\-level\fP
1687 \fIbit\-rate\fP
1753 > ipmitool \-I open channel info 1
1758 Channel Protocol Type : IPMB\-1.0
1759 Session Support : session\-based
1922 > ipmitool \-I \fIinterface\fR lan set \fIchannel\fR cipher_privs uaXXXXXXXXXXXXX
1931 <\fBthresh_num\fR> If non-zero, this value determines the number of sequential bad passwords
2097 OEM\-Defined option #0
2102 OEM\-Defined option #1
2107 OEM\-Defined option #2
2141 Displays information regarding the high\-level
2148 This command will return the Power\-On Hours counter.
2178 \fIalways\-on\fP
2188 \fIalways\-off\fP
2240 Initiate a soft\-shutdown of OS via ACPI. This can be done in a
2247 \fIbootdev\fP <\fBdevice\fR> [<\fIclear\-cmos\fP=\fByes\fR|\fBno\fR>] [<\fIoptions\fP=\fBhelp,...\f…
2251 The \fIclear\-cmos\fP option, if supplied, will instruct the BIOS to
2312 \fI0\fP - Set In Progress
2314 \fI1\fP - Service Partition Selector
2316 \fI2\fP - Service Partition Scan
2318 \fI3\fP - BMC Boot Flag Valid Bit Clearing
2320 \fI4\fP - Boot Info Acknowledge
2322 \fI5\fP - Boot Flags
2324 \fI6\fP - Boot Initiator Info
2326 \fI7\fP - Boot Initiator Mailbox
2349 Force boot from default hard-drive
2354 Force boot from default hard-drive, request Safe Mode
2374 …Valid Bit Clearing and are as follows: Any option can be prefixed with "no-" to invert the sense…
2395 Clear valid bit on push button reset / soft-reset
2450 address, IPMB-0 Address, FRU ID, Site/Entity ID, and Site/Entity Type.
2458 \fI0x00\fP - Cold Reset
2461 \fI0x01\fP - Warm Reset
2464 \fI0x02\fP - Graceful Reboot
2467 \fI0x03\fP - Issue Diagnostic Interrupt
2470 \fI0x04\fP - Quiesce [AMC only]
2473 \fI0x05-0xFF\fP - Cold Reset
2517 > ipmitool \-v raw 0x0 0xf
2591 Event\-Only Sensor Record
2614 valid entity ids on the target system by issuing the \fIsdr elist\fP command.
2621 a local SDR cache of the remote managed system with the \fI\-S <file>\fP
2641 NOTE: System Event Log (SEL) entry\-times are displayed as
2642 `Pre\-Init Time\-stamp' if the SEL clock needs to be set.
2675 Displays the first \fIcount\fR (least\-recent) entries in the SEL.
2681 Displays the last \fIcount\fR (most\-recent) entries in the SEL.
2733 form "MM/DD/YYYY HH:MM:SS". Note that hours are in 24\-hour
2761 \fIunr\fP Upper Non\-Recoverable
2765 \fIunc\fP Upper Non\-Critical
2767 \fIlnc\fP Lower Non\-Critical
2771 \fIlnr\fP Lower Non\-Recoverable
2778 Lower Non\-Recoverable, Lower Critical, and Lower Non\-Critical.
2784 Upper Non\-Critical, Upper Critical, and Upper Non\-Recoverable.
2839 Remote target IPMB address.
2883 Retrieve information about the Serial\-Over\-LAN configuration on
2898 with the updates to the set\-in\-progress parameter.
2904 \fIset\-in\-progress\fP
2905 set\-complete set\-in\-progress commit\-write
2910 \fIforce\-encryption\fP
2913 \fIforce\-authentication\fP
2916 \fIprivilege\-level\fP
2919 \fIcharacter\-accumulate\-level\fP
2922 \fIcharacter\-send\-threshold\fP
2925 \fIretry\-count\fP
2928 \fIretry\-interval\fP
2932 \fInon\-volatile\-bit\-rate\fP
2937 \fIvolatile\-bit\-rate\fP
2994 I2C Master Write\-Read IPMI command.
3057 Return the full NAC name of a target identified by ipmi name.
3064 q - Quiet. Displays output only at the start and end of the process.
3154 This command allows Serial-over-LAN sessions to be established with Tyan
3165 two-way session. Format of ipaddr is XX.XX.XX.XX
3177 Confiure SOL session as read-only or read-write. Sessions are read-write
3210 removing passwords from administrator\-level accounts.
3245 a 2.4\-based kernel in order for ipmitool to work:
3257 a 2.6\-based kernel in order for ipmitool to work:
3286 can perform this task automatically at start\-up.
3291 ipmitool \fB\-I\fR \fIopen\fP <\fIcommand\fP>
3297 ipmitool \fB\-I\fR \fIbmc\fP <\fIcommand\fP>
3303 32\-bit \fBELF\fR kernel module for the bmc driver.
3306 64\-bit \fBELF\fR kernel module for the bmc driver.
3315 ipmitool \fB\-I\fR \fIlipmi\fP <\fIexpression\fP>
3322 IPMI\-over\-LAN uses version 1 of the Remote Management Control
3323 Protocol (RMCP) to support pre\-OS and OS\-absent management.
3324 RMCP is a request\-response protocol delivered using UDP
3327 The LAN interface is an authentication multi\-session connection;
3330 password/key or MD5 message\-digest algorithm. ipmitool will
3335 \fB\-I\fR \fIlan\fP option:
3338 ipmitool \fB\-I\fR \fIlan\fP \fB\-H\fR <\fIhostname\fP>
3339 [\fB\-U\fR <\fIusername\fP>] [\fB\-P\fR <\fIpassword\fP>] <\fIcommand\fP>
3359 RMCP+ session establishment uses a symmetric challenge\-response
3360 protocol called RAKP (\fBRemote Authenticated Key\-Exchange Protocol\fR)
3365 SHA1, and encryption is performed with AES\-CBC\-128. Role\-level logins
3374 \fB\-I\fR \fIlanplus\fP option:
3377 ipmitool \fB\-I\fR \fIlanplus\fP
3378 \fB\-H\fR <\fIhostname\fP>
3379 [\fB\-U\fR <\fIusername\fP>]
3380 [\fB\-P\fR <\fIpassword\fP>]
3384 lan interface with ipmitool. With the exception of the \fB\-A\fR and
3385 \fB\-C\fR options the rest of the command line options are identical to
3388 The \fB\-C\fR option allows you specify the authentication, integrity,
3391 22\-19. The default cipher suite is \fI3\fP which specifies
3392 RAKP\-HMAC\-SHA1 authentication, HMAC\-SHA1\-96 integrity, and AES\-CBC\-128
3400 You can tell ipmitool to use the FreeIPMI interface with the -I option:
3402 ipmitool \fB\-I\fR \fIfree\fP <\fIcommand\fP>
3408 Inter-module Bus) Interface through the /dev/imb device.
3410 You can tell ipmitool to use the IMB interface with the -I option:
3412 ipmitool \fB\-I\fR \fIimb\fP <\fIcommand\fP>
3418 > ipmitool \-I lan \-H 1.2.3.4 \-f passfile sdr list
3420 Baseboard 1.25V | 1.24 Volts | ok
3422 Baseboard 2.5V | 2.49 Volts | ok
3424 Baseboard 3.3V | 3.32 Volts | ok
3428 > ipmitool \-I lan \-H 1.2.3.4 \-f passfile sensor get "Baseboard 1.25V"
3432 Sensor ID : Baseboard 1.25V (0x10)
3436 Sensor Reading : 1.245 (+/\- 0.039) Volts
3440 Lower Non\-Recoverable : na
3444 Lower Non\-Critical : 1.107
3446 Upper Non\-Critical : 1.382
3450 Upper Non\-Recoverable : na
3454 > ipmitool \-I lan \-H 1.2.3.4 \-f passfile chassis power status
3460 > ipmitool \-I lan \-H 1.2.3.4 \-f passfile chassis power on